Product successfully added to your shopping cart
1SDA072738R1
ABB
1
E1.2C 800 Ekip Hi-Touch LSI 4p WMP
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax" > E1.2
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 30d5c8b9-87f7-488c-98c4-1e7a77387f74 Italy |
| Simplified SCIP | 1685da76-d5a8-4cb6-ab7a-e08646b53dc5 Denmark |
| 17addf4a-788c-45e6-9a2d-89de7ee9203c Germany | |
| df31192c-f7e8-44be-b1a3-5517d4e5fa70 Hungary | |
| 477ab873-b09d-4239-9cd3-ae1dcd3bf926 Sweden | |
| 5d073a3a-88e6-47a2-b0ed-131a589ea9e7 Germany | |
| 9570d7e8-5247-4968-9825-a361e6963f82 Croatia | |
| 08b6fb81-c478-497e-a62c-e447ac63d63e Germany | |
| 49baa32f-6a0b-457d-aa51-3e4a77c6eed4 France | |
| 1685da76-d5a8-4cb6-ab7a-e08646b53dc5 Denmark | |
| 17addf4a-788c-45e6-9a2d-89de7ee9203c Germany | |
| e77a5c6c-ac70-4684-aece-65a17344303f Greece | |
| 1ce29a26-2ba2-489c-b830-dc6ba0df55d0 Germany | |
| 81ad5291-0545-49dc-9fdd-7842dc26a35b Norway | |
| 9704badc-1c96-4341-b344-0042b9cf6b90 Finland | |
| 5217aa7d-14d5-4214-b391-49e5e18a075d Czech Republic | |
| 3a28eb4b-f1da-4b95-b148-925513e860a7 Poland | |
| 6651658f-6061-49d0-9af7-8c4b203e66c6 Netherlands | |
| 658acfc7-e518-470f-94f4-cf287b37c670 Poland | |
| be15e2ff-f8b6-45ab-a6c9-8608052793b6 France | |
| 08b6fb81-c478-497e-a62c-e447ac63d63e Germany | |
| 5827e7b1-64b3-4bdf-b500-d90e599c94a1 Hungary | |
| 83f5048c-1e85-4ba8-ad38-414c333d1cdb Belgium | |
| 4e5269c7-7d33-47bb-8ed3-1475ed1ff161 Spain | |
| 38ce0d59-ae0b-4a5c-aa22-85246344e559 Portugal | |
| b8d6eeb3-597f-4c15-b577-6511019fcab7 Sweden | |
| 6493a302-1180-42cd-8da8-4815a601fccd Estonia | |
| 4e5269c7-7d33-47bb-8ed3-1475ed1ff161 Spain | |
| b3dba147-bd66-425a-a5d7-c408d7a47f53 Poland | |
| 49baa32f-6a0b-457d-aa51-3e4a77c6eed4 France | |
| 477ab873-b09d-4239-9cd3-ae1dcd3bf926 Sweden | |
| 5d073a3a-88e6-47a2-b0ed-131a589ea9e7 Germany | |
| 557ae9d7-5912-4bb5-9501-ebb08114c31f Bulgaria | |
| 5217aa7d-14d5-4214-b391-49e5e18a075d Czech Republic | |
| df31192c-f7e8-44be-b1a3-5517d4e5fa70 Hungary | |
| 6651658f-6061-49d0-9af7-8c4b203e66c6 Netherlands | |
| 3a28eb4b-f1da-4b95-b148-925513e860a7 Poland | |
| be15e2ff-f8b6-45ab-a6c9-8608052793b6 France | |
| e77a5c6c-ac70-4684-aece-65a17344303f Greece | |
| 6493a302-1180-42cd-8da8-4815a601fccd Estonia | |
| 1ce29a26-2ba2-489c-b830-dc6ba0df55d0 Germany | |
| b3dba147-bd66-425a-a5d7-c408d7a47f53 Poland | |
| 5827e7b1-64b3-4bdf-b500-d90e599c94a1 Hungary | |
| 658acfc7-e518-470f-94f4-cf287b37c670 Poland | |
| f01e61d0-cede-4997-89aa-149d0561faf4 Belgium | |
| 38ce0d59-ae0b-4a5c-aa22-85246344e559 Portugal | |
| b8d6eeb3-597f-4c15-b577-6511019fcab7 Sweden | |
| 9704badc-1c96-4341-b344-0042b9cf6b90 Finland | |
| 9570d7e8-5247-4968-9825-a361e6963f82 Croatia | |
| 9379daa6-2269-4691-b3c7-1efb5d6f6710 Germany | |
| 83f5048c-1e85-4ba8-ad38-414c333d1cdb Belgium | |
| f01e61d0-cede-4997-89aa-149d0561faf4 Belgium | |
| 81ad5291-0545-49dc-9fdd-7842dc26a35b Norway | |
| 557ae9d7-5912-4bb5-9501-ebb08114c31f Bulgaria | |
| 9379daa6-2269-4691-b3c7-1efb5d6f6710 Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZACPEFAJ200A000000XX |
| EAN | 8015644765880 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 348 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 20 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 23 kg |
| Package Level 1 EAN | 8015644765880 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0065 |
| Technical | |
| Connecting Capacity | 500 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 100 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Hi-Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 800 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 50 kA |
| Overload release current setting (EF002336) | 320.0 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 480.0 A |
| Adjustment range undelayed short-circuit release (EF007131) | 1200.0 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Connection at separate chassis part |
| Device construction (EF008240) | Built-in device slide-in technique (withdrawable) |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 4 |
| Position of connection for main current circuit (EF006671) | Connection at separate chassis part |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E1.2C 800 Ekip Hi-Touch LSI 4p WMP - ABB - E1.2C800 - 1SDA072738R1 | 96 Kbytes |
![]() |
| E1.2C800 1SDA072738R1 ABB E1.2C 800 Ekip Hi-Touch LSI 4p WMP | 76 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.