Product successfully added to your shopping cart
1SDA072225R1
ABB
1
E1.2C 1600 Ekip Touch LSI 3p WMP
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax" > E1.2
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | dadd1ef1-7abd-4a32-a737-b3442d33963e Italy |
| Simplified SCIP | 00fe6fb8-037c-4867-80af-96323b8bd3cf Denmark |
| 5afaeb6f-7957-422c-b599-d557c228b460 Germany | |
| a02966b2-95a9-4b2d-8de5-53e72880e12f Finland | |
| 71bc220e-b267-4f96-9fce-8bf0e3304125 Sweden | |
| d4b9388c-05db-4dd5-8e4e-07965e62c41f Germany | |
| c78a0c63-40b7-4d58-9037-3efea44f960c Bulgaria | |
| 8d32a157-bd44-4bb0-b43e-c8fa1b13bd20 Belgium | |
| 807fcb34-42cb-4369-9ccd-8431f693d9f4 Belgium | |
| f1ea500b-c4ff-45e1-8847-d3c6d6956176 Norway | |
| 2eb2211b-dcc8-4f30-a549-766190ded60b Germany | |
| 5afaeb6f-7957-422c-b599-d557c228b460 Germany | |
| aa0838f3-cf64-46dc-9b1b-166d723e97d4 Poland | |
| 00fe6fb8-037c-4867-80af-96323b8bd3cf Denmark | |
| 9824e30e-4097-4a4b-b2e4-00c6bb75914f Greece | |
| a2d270c2-18ef-43fb-a711-457e71716ebf Poland | |
| 2eb2211b-dcc8-4f30-a549-766190ded60b Germany | |
| d4b9388c-05db-4dd5-8e4e-07965e62c41f Germany | |
| 8d32a157-bd44-4bb0-b43e-c8fa1b13bd20 Belgium | |
| 6efb689e-1665-42c2-9f7f-6f4ff940461b Croatia | |
| cb01b63c-6316-456f-bc27-96e066685098 Portugal | |
| fa6906a6-8f71-4d7a-a9a2-8c66469cdb41 Netherlands | |
| aa0838f3-cf64-46dc-9b1b-166d723e97d4 Poland | |
| 02a4d04c-7448-45e2-9560-371dc52279a0 Poland | |
| f62091b3-5fe9-4bdf-8a1e-2a533637e36c Hungary | |
| c78a0c63-40b7-4d58-9037-3efea44f960c Bulgaria | |
| e7ec7fa2-a56d-4b38-9194-80b79714d457 Germany | |
| 3a974458-27e9-4682-8417-266f49daee36 France | |
| f1ea500b-c4ff-45e1-8847-d3c6d6956176 Norway | |
| a02966b2-95a9-4b2d-8de5-53e72880e12f Finland | |
| 08e4d015-4f02-4c6b-9ad5-ef9f3e9adcdd Germany | |
| 6efb689e-1665-42c2-9f7f-6f4ff940461b Croatia | |
| 5041af42-71c4-40f1-9a9c-ba89f34b683f Sweden | |
| cb01b63c-6316-456f-bc27-96e066685098 Portugal | |
| 9073530e-aa25-4a8e-a264-ce2e77dcfb05 Czech Republic | |
| 9873a070-8627-43c6-97f4-747322192258 Hungary | |
| 56cf527c-10be-4fad-9312-07b2c1a1d2b9 Spain | |
| 807fcb34-42cb-4369-9ccd-8431f693d9f4 Belgium | |
| 9873a070-8627-43c6-97f4-747322192258 Hungary | |
| 56cf527c-10be-4fad-9312-07b2c1a1d2b9 Spain | |
| d269fc87-7830-4bf8-9415-435d69677d6d Estonia | |
| fa6906a6-8f71-4d7a-a9a2-8c66469cdb41 Netherlands | |
| 71bc220e-b267-4f96-9fce-8bf0e3304125 Sweden | |
| f62091b3-5fe9-4bdf-8a1e-2a533637e36c Hungary | |
| 9073530e-aa25-4a8e-a264-ce2e77dcfb05 Czech Republic | |
| 9824e30e-4097-4a4b-b2e4-00c6bb75914f Greece | |
| dd522f6a-4db2-402d-8ef3-414f6d518011 France | |
| d269fc87-7830-4bf8-9415-435d69677d6d Estonia | |
| 02a4d04c-7448-45e2-9560-371dc52279a0 Poland | |
| 5041af42-71c4-40f1-9a9c-ba89f34b683f Sweden | |
| 08e4d015-4f02-4c6b-9ad5-ef9f3e9adcdd Germany | |
| e7ec7fa2-a56d-4b38-9194-80b79714d457 Germany | |
| dd522f6a-4db2-402d-8ef3-414f6d518011 France | |
| 3a974458-27e9-4682-8417-266f49daee36 France | |
| a2d270c2-18ef-43fb-a711-457e71716ebf Poland | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1CSEJAE000A000000XX |
| EAN | 8015644760755 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 278 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 18 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8015644760755 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0024 |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 3000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 400 W |
| Rated Current (In) | 1600 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1600 A |
| Rated Voltage (Ur) | 690 V |
| Release | Ekip Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 1600 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 50 kA |
| Overload release current setting (EF002336) | 1600 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 16000 A |
| Adjustment range undelayed short-circuit release (EF007131) | 2400.0 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Connection at separate chassis part |
| Device construction (EF008240) | Built-in device slide-in technique (withdrawable) |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Connection at separate chassis part |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E1.2C 1600 Ekip Touch LSI 3p WMP - ABB - E1.2C1600 - 1SDA072225R1 | 95 Kbytes |
![]() |
| E1.2C1600 1SDA072225R1 ABB E1.2C 1600 Ekip Touch LSI 3p WMP | 75 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.