Product successfully added to your shopping cart
1SDA072858R1
ABB
1
E1.2C 1600 Ekip Hi-Touch LSI 4p WMP
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax" > E1.2
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 5d7ecdae-12b3-4be4-b674-61f94511addd Italy |
| Simplified SCIP | 7fe359a6-4597-4531-b770-da8f0ba581db Norway |
| e1da7a87-0c5b-49cd-b88f-76fd8a2d4160 Germany | |
| 3b4934bc-3906-47b6-873d-cc1cdd231d71 Croatia | |
| fcc43640-697d-4f6f-9d34-1fc1d618adf8 Finland | |
| 44f0976d-60c2-4c16-b889-823b1391aa90 Germany | |
| 0057aadd-7e96-41b7-a859-67d1daaa2b0a Sweden | |
| f462e785-5a98-4ca6-aacd-6b940e0f82ca Denmark | |
| dc3808de-e33e-4db8-8a22-d1cf91d701f9 Bulgaria | |
| e1da7a87-0c5b-49cd-b88f-76fd8a2d4160 Germany | |
| 0410dd2e-e1ba-4917-bdef-000800f5e97d Belgium | |
| 32f7a11e-20e9-4d50-85ee-1a6e8070b962 Germany | |
| ac5d3f4d-e180-4f34-9119-05f43dffe83f Poland | |
| ef097227-c28e-424d-9e0e-a6bd061cb8ce Poland | |
| c9c0bff7-f19d-4103-b0e0-e1edd01c73c0 Greece | |
| 7fe359a6-4597-4531-b770-da8f0ba581db Norway | |
| 44f0976d-60c2-4c16-b889-823b1391aa90 Germany | |
| 32f7a11e-20e9-4d50-85ee-1a6e8070b962 Germany | |
| f462e785-5a98-4ca6-aacd-6b940e0f82ca Denmark | |
| 824a378e-d43d-4e47-9488-5a9da5950b78 Portugal | |
| fcc128ef-37e7-4ed9-b031-a10d3095bb4a Poland | |
| 707610a6-4b0b-43e3-8b04-f3a230e27315 Netherlands | |
| ef097227-c28e-424d-9e0e-a6bd061cb8ce Poland | |
| 5bbfdca7-2c26-45e5-a92a-321f8601b4e6 Belgium | |
| 0410dd2e-e1ba-4917-bdef-000800f5e97d Belgium | |
| 53903c2f-de33-45a4-b312-5d6b77a2d4d4 Germany | |
| 402d8ca4-aa4e-4ff5-8ca2-1749cb2eb57e Hungary | |
| 2b871150-e0de-4535-980d-6816c2b1037d Germany | |
| 44f6d7d1-c8cf-4bf0-8210-835faf69618b Czech Republic | |
| dc3808de-e33e-4db8-8a22-d1cf91d701f9 Bulgaria | |
| 9fffa1a6-c4c8-435f-ba23-885e82012802 France | |
| 44f6d7d1-c8cf-4bf0-8210-835faf69618b Czech Republic | |
| fcc43640-697d-4f6f-9d34-1fc1d618adf8 Finland | |
| 824a378e-d43d-4e47-9488-5a9da5950b78 Portugal | |
| 3b4934bc-3906-47b6-873d-cc1cdd231d71 Croatia | |
| 8fdc0723-403c-41ca-8376-f6f58ec1bb72 Sweden | |
| 497d19ac-5f94-422a-bb31-827a0fec5fa8 Spain | |
| 5bbfdca7-2c26-45e5-a92a-321f8601b4e6 Belgium | |
| 8b8b517f-7153-447c-b3b3-9ddc35bad78c Hungary | |
| 402d8ca4-aa4e-4ff5-8ca2-1749cb2eb57e Hungary | |
| c9c0bff7-f19d-4103-b0e0-e1edd01c73c0 Greece | |
| f7ec5c32-92de-4398-b65d-f3126b551321 France | |
| 74670c9e-367e-47ef-b0d3-d2e16414cf15 Estonia | |
| fcc128ef-37e7-4ed9-b031-a10d3095bb4a Poland | |
| 497d19ac-5f94-422a-bb31-827a0fec5fa8 Spain | |
| 8b8b517f-7153-447c-b3b3-9ddc35bad78c Hungary | |
| 74670c9e-367e-47ef-b0d3-d2e16414cf15 Estonia | |
| 707610a6-4b0b-43e3-8b04-f3a230e27315 Netherlands | |
| 53903c2f-de33-45a4-b312-5d6b77a2d4d4 Germany | |
| 2b871150-e0de-4535-980d-6816c2b1037d Germany | |
| 8fdc0723-403c-41ca-8376-f6f58ec1bb72 Sweden | |
| f7ec5c32-92de-4398-b65d-f3126b551321 France | |
| 9fffa1a6-c4c8-435f-ba23-885e82012802 France | |
| ac5d3f4d-e180-4f34-9119-05f43dffe83f Poland | |
| 0057aadd-7e96-41b7-a859-67d1daaa2b0a Sweden | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZACSEJAJ200A000000XX |
| EAN | 8015644767082 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 348 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 20 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 23 kg |
| Package Level 1 EAN | 8015644767082 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0065 |
| Technical | |
| Connecting Capacity | 1200 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 3000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 400 W |
| Rated Current (In) | 1600 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1600 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Hi-Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 1600 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 50 kA |
| Overload release current setting (EF002336) | 1600 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 16000 A |
| Adjustment range undelayed short-circuit release (EF007131) | 2400.0 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Connection at separate chassis part |
| Device construction (EF008240) | Built-in device slide-in technique (withdrawable) |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 4 |
| Position of connection for main current circuit (EF006671) | Connection at separate chassis part |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E1.2C 1600 Ekip Hi-Touch LSI 4p WMP - ABB - E1.2C1600 - 1SDA072858R1 | 96 Kbytes |
![]() |
| E1.2C1600 1SDA072858R1 ABB E1.2C 1600 Ekip Hi-Touch LSI 4p WMP | 76 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.