Product successfully added to your shopping cart
1SDA072816R1
ABB
1
E1.2C 1250 Ekip Touch LSIG 4p WMP
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax" > E1.2
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 42c3dc2f-138f-43f8-a950-741f70cea32f Italy |
| Simplified SCIP | 846b776c-0448-482f-a5b1-e34749d3fdf5 Germany |
| 15a18f19-783a-4b32-97c3-653fe6dcf78c Croatia | |
| 8eb60507-e0dc-4daf-ac43-a1e0199c6950 Germany | |
| 97c6c5f3-3fe9-4531-9ea1-e6ca088406c2 Sweden | |
| 4a4e29f2-68b8-48f6-9815-2ef76d4b8f39 Hungary | |
| f3d23c5e-1ee7-44b0-8166-955b51061a6d France | |
| c48ce8cd-4746-4658-a5e1-2cfe63b1e339 Greece | |
| 6b253f73-1563-49b3-9255-fb9469f8b959 Norway | |
| 663031ba-b4f4-4003-adfc-ffff7ed3f6a2 Denmark | |
| d9426e4a-41f4-4842-8b2f-c5f726c3a6b7 Germany | |
| d230d43a-a0b0-45ba-8989-f0f90d103f8a Germany | |
| 1723cecd-c9b7-46e0-a95c-4726c1fd6297 Finland | |
| e8310bc7-2927-4942-b2f6-17e171eb7876 Portugal | |
| 49ea81f5-c63e-4738-acb4-df0a1d4f39cc Czech Republic | |
| 4a4e29f2-68b8-48f6-9815-2ef76d4b8f39 Hungary | |
| 411d9ac7-1a95-4060-baab-65182f1e031e Poland | |
| 0cbab4f0-2955-496d-9f92-cb067891f259 Poland | |
| c9bef13f-be95-4ca9-968c-755ef3e00e06 Netherlands | |
| 846b776c-0448-482f-a5b1-e34749d3fdf5 Germany | |
| d1c77e7b-3c76-4c22-a527-759113229501 France | |
| af9ae5ea-b60f-40db-8b90-9dce20fa2f3a Spain | |
| 81733e1f-8819-464e-82ea-72ad3ed15ce9 Belgium | |
| ff1ccaec-73bd-4a77-8ca5-9b35238a05c4 Hungary | |
| e8310bc7-2927-4942-b2f6-17e171eb7876 Portugal | |
| 03f838ce-2658-4f6d-a60d-ce7d0df8dd35 Sweden | |
| af9ae5ea-b60f-40db-8b90-9dce20fa2f3a Spain | |
| fe292d60-f8ff-4913-b5d2-2fcae95d5a96 Estonia | |
| f3d23c5e-1ee7-44b0-8166-955b51061a6d France | |
| c6992185-3061-4d12-a9b1-03dcbce05933 Poland | |
| 8eb60507-e0dc-4daf-ac43-a1e0199c6950 Germany | |
| 97c6c5f3-3fe9-4531-9ea1-e6ca088406c2 Sweden | |
| f26b2164-0f0f-407d-afcf-53071e59e052 Bulgaria | |
| 49ea81f5-c63e-4738-acb4-df0a1d4f39cc Czech Republic | |
| c48ce8cd-4746-4658-a5e1-2cfe63b1e339 Greece | |
| 411d9ac7-1a95-4060-baab-65182f1e031e Poland | |
| d1c77e7b-3c76-4c22-a527-759113229501 France | |
| fe292d60-f8ff-4913-b5d2-2fcae95d5a96 Estonia | |
| ff1ccaec-73bd-4a77-8ca5-9b35238a05c4 Hungary | |
| c9bef13f-be95-4ca9-968c-755ef3e00e06 Netherlands | |
| c6992185-3061-4d12-a9b1-03dcbce05933 Poland | |
| d9426e4a-41f4-4842-8b2f-c5f726c3a6b7 Germany | |
| 0cbab4f0-2955-496d-9f92-cb067891f259 Poland | |
| 528225c9-6fb9-439b-bb6e-348b7a97e7a7 Belgium | |
| 1723cecd-c9b7-46e0-a95c-4726c1fd6297 Finland | |
| 03f838ce-2658-4f6d-a60d-ce7d0df8dd35 Sweden | |
| 15a18f19-783a-4b32-97c3-653fe6dcf78c Croatia | |
| 79db7504-a28b-43ab-b03f-83676a35a324 Germany | |
| 663031ba-b4f4-4003-adfc-ffff7ed3f6a2 Denmark | |
| d230d43a-a0b0-45ba-8989-f0f90d103f8a Germany | |
| 6b253f73-1563-49b3-9255-fb9469f8b959 Norway | |
| 81733e1f-8819-464e-82ea-72ad3ed15ce9 Belgium | |
| 528225c9-6fb9-439b-bb6e-348b7a97e7a7 Belgium | |
| f26b2164-0f0f-407d-afcf-53071e59e052 Bulgaria | |
| 79db7504-a28b-43ab-b03f-83676a35a324 Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZACREHAF000A000000XX |
| EAN | 8015644766665 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 348 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 20 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 23 kg |
| Package Level 1 EAN | 8015644766665 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0065 |
| Technical | |
| Connecting Capacity | 1000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 244 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 1250 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 50 kA |
| Overload release current setting (EF002336) | 1250 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 12500 A |
| Adjustment range undelayed short-circuit release (EF007131) | 1875.0 A |
| Integrated earth fault protection (EF007296) | Yes |
| Type of electrical connection of main circuit (EF006819) | Connection at separate chassis part |
| Device construction (EF008240) | Built-in device slide-in technique (withdrawable) |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 4 |
| Position of connection for main current circuit (EF006671) | Connection at separate chassis part |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E1.2C 1250 Ekip Touch LSIG 4p WMP - ABB - E1.2C1250 - 1SDA072816R1 | 96 Kbytes |
![]() |
| E1.2C1250 1SDA072816R1 ABB E1.2C 1250 Ekip Touch LSIG 4p WMP | 76 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.