ANUNCIAR
1SDA071375R1 ABB E1.2B 800 Ekip Touch LSI 4p F F View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SDA071375R1 ABB E1.2B 800 Ekip Touch LSI 4p F F

1SDA071375R1

ABB

E1.2B 800 Ekip Touch LSI 4p F F

More details


Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection

Rack "Megamax-Emax" > E1.2

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $4,066.55
Unit price: $4,066.55
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions9AKK108468A2360
Environmental Product Declaration - EPD9AKK108468A1900
9AKK108468A3028
Extended Product LifetimeLifetime Extension Services are Offered
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 76.4 %
Material Compliance
REACH Declaration9AKK108466A1425
RoHS Declaration9AKK108466A1424
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
Toxic Substances Control Act - TSCA9AKK108467A8326
SCIPa63af0ea-68a0-4313-850d-57141423b5c0 China
Simplified SCIP36d7b247-873a-4f56-962b-a005d0204909 Germany
726f32df-0314-489d-be29-1f4eb1a926de Finland
ddee9c9b-d192-4a85-9dcf-03eac3b1dfdf Denmark
6e6879b8-2c19-432c-b594-7f4063c1a31c Germany
47b096cc-fa95-4812-8d33-3d98e1595e5d Sweden
ee5b35e1-a9d1-461c-9ee3-4b239b8b3689 France
8194b505-2330-46c0-a09c-74b899be94e8 Poland
12185189-f363-445e-bd41-71e909fd5a07 Poland
59699957-cf5d-4f0c-8f68-6fed02af0c24 Estonia
e29c09f7-e459-4047-ab71-5249e8abaded Hungary
7319d4f1-9d4d-4825-a76a-957289b3a0f0 Portugal
6443ce8c-6ec4-4b08-87f2-b46e9eee0507 Spain
93b51cee-bc5a-4e99-8e1f-c37ad202a510 Norway
749dd5a2-af58-42fe-a0d1-d58916bfe272 Greece
7b5ac94a-5bf5-42fc-8a75-78963b8fa621 Belgium
415159f1-0d13-4ec3-9057-8691529ddee0 Hungary
502264cd-2754-425a-8343-737ccd75d623 Croatia
2e188413-5bb3-42d8-80ba-f8487146a831 Germany
53b9fbbe-73c6-445b-a00d-e2670d3ade6d Bulgaria
952f900b-baa2-4e80-9387-b98a360b26e1 Sweden
358debf7-dcfa-4567-9d32-2cf90a023fff Czech Republic
b0cc899b-6cf4-4f7e-8369-94eba66c5d87 Poland
b5fd9bd5-a7da-4367-befe-ef4004eca8dc Netherlands
40263e75-731f-4458-80bd-8ab6bfa2c0cc Germany
e6fe3863-517b-4b9c-bff4-787ed7f38e3a Germany
6c5f03be-76ab-444c-824b-407e31d7f424 France
c139c99c-e99b-4df8-923a-5f576b4243bf Belgium
Environmental
Environmental Information9AKK108467A6707
Ordering
Order Code US and CanadaZABPEFBE000A000000XX
EAN8015644752255
Minimum Order Quantity1 piece
Customs Tariff Number85362090
Dimensions
Product Net Width280 mm
Product Net Height296 mm
Product Net Depth / Length183 mm
Product Net Weight16 kg
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width350 mm
Package Level 1 Height350 mm
Package Level 1 Depth / Length330 mm
Package Level 1 Gross Weight18 kg
Package Level 1 EAN8015644752255
Additional Information
Product Main TypeSACE Emax 2
Product NameAir Circuit Breaker
Product TypeAir Circuit Breaker
VersionF
CAD Dimensional Drawing1SDH001252R0042
Technical
Connecting Capacity500 mm²
Current TypeAC
Electrical DurabilityUe =< 440 V 8000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Mechanical Durability20000 cycle
60 cycles per hour
Neutral Pole Current ([%Iu])100 %
Number of Poles4P
Power Loss50 W
Rated Current (In)800 A
Rated Impulse Withstand Voltage (Uimp)acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui)AC 1000 V
Rated Operational Voltage690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 42 kA
(230 V AC) 42 kA
(380 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(660 V AC) 42 kA
(690 V AC) 42 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics)100 %
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 42 kA
for 3 s 24 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
Rated Uninterrupted Current (Iu)800 A
Rated Voltage (Ur)690 V
Recommended Screw DriverM12
ReleaseEkip Touch LSI
Release TypeEL
Short-Circuit Performance LevelB
StandardsIEC
Sub-typeE1.2
Suitable for IT NetworksYes, 690V
Terminal Connection TypeFront
Terminal TypeBolt
Tightening Torque45 N·m
Certificates and Declarations
ATEX CertificateNo certification needed
CSA CertificateNo certification needed
CSA Certificate (Intrinsic Safe)No certification needed
Data Sheet, Technical Information1SDC200023D0209
Declaration of Conformity - CE9AKK106713A5546
EU Data Act Compliance Declaration1SDH002560A1001
UL CertificateNo certification needed
VDE CertificateNo certification needed
Mechanical Drawings1SDH000999R0101
Wiring Diagram1SDM000091R0001
Instructions and Manuals1SDH000999R0002
Instructions and Manuals (Part 2)1SDH001316R1002
External Classifications and Standards
ETIM 9EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)4926 >> Air circuit breakers
Object Classification CodeQ
UNSPSC39121615
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
eClassV11.1 : 27370409

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.