Product successfully added to your shopping cart
1SDA072212R1
ABB
1
E1.2B 1600 Ekip Dip LSI 3p WMP
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax" > E1.2
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 76c46619-ce70-40db-8216-015055ae0737 Italy |
| Simplified SCIP | e3f314f1-a49c-44b9-a0f8-07b83ca65df0 Hungary |
| 6665d440-4bd0-48a2-96f1-61440f3d2cef Germany | |
| 7a080780-0912-4f1f-b294-2dfa75b4b780 Germany | |
| d51c8b39-1b6f-4747-bc8f-07953c4f490f Bulgaria | |
| 8615d38f-b558-462c-987a-3e50f694c1c5 Portugal | |
| e3f314f1-a49c-44b9-a0f8-07b83ca65df0 Hungary | |
| 62c4a5b3-6fbb-4814-aa0d-a1ab4e1300e8 Croatia | |
| a64d7302-d339-449a-8eb9-e159dbb64179 Sweden | |
| 422b49a8-f244-4908-9021-ee99fac55def Czech Republic | |
| 51c91b53-33b9-4951-bce1-9c3f194fef10 Norway | |
| 6edc935e-4b1c-4fae-b5a4-cb928b4da2c7 France | |
| 422b49a8-f244-4908-9021-ee99fac55def Czech Republic | |
| 516b67a9-3ae3-4304-a011-4a8d79006ac9 Finland | |
| 318fba27-0e1e-47de-b714-c39f9d187ebf France | |
| e000a2dc-33d5-42f6-9602-a842904a1aec Hungary | |
| 7a80bcc2-ffbb-4bad-8559-29eb2d1ea951 Spain | |
| 55850459-c539-4289-9e66-79992e747e39 Belgium | |
| 11c37535-1dcc-4678-a704-a2832dc696f8 Denmark | |
| 5ed9c6a5-7772-4c77-bc9e-0b0e085af61c Germany | |
| 2faeb605-1a5f-46e5-9f6e-04b5ed933d56 Sweden | |
| 516b67a9-3ae3-4304-a011-4a8d79006ac9 Finland | |
| 8615d38f-b558-462c-987a-3e50f694c1c5 Portugal | |
| 51c91b53-33b9-4951-bce1-9c3f194fef10 Norway | |
| c833cc95-df64-4654-b0e5-839bac8eed4e Germany | |
| d51c8b39-1b6f-4747-bc8f-07953c4f490f Bulgaria | |
| 0ffbe236-dd8e-46d4-8f29-232971677a76 Estonia | |
| 04e1f526-d429-4b39-9701-e826184ba1e2 Poland | |
| 5bd5969e-bbf5-41e8-9abd-5972b2e0add3 Greece | |
| 318fba27-0e1e-47de-b714-c39f9d187ebf France | |
| e000a2dc-33d5-42f6-9602-a842904a1aec Hungary | |
| b6554562-cee8-4cc2-897d-bda9876c7a94 Netherlands | |
| 0ffbe236-dd8e-46d4-8f29-232971677a76 Estonia | |
| 7a80bcc2-ffbb-4bad-8559-29eb2d1ea951 Spain | |
| 2faeb605-1a5f-46e5-9f6e-04b5ed933d56 Sweden | |
| 734d3f50-4f6b-45a3-9f51-e0aa7a423b76 Germany | |
| bbf539fa-aa6e-464f-833c-291ed8760246 Poland | |
| 6edc935e-4b1c-4fae-b5a4-cb928b4da2c7 France | |
| a64d7302-d339-449a-8eb9-e159dbb64179 Sweden | |
| 6665d440-4bd0-48a2-96f1-61440f3d2cef Germany | |
| 7a080780-0912-4f1f-b294-2dfa75b4b780 Germany | |
| 04e1f526-d429-4b39-9701-e826184ba1e2 Poland | |
| b6554562-cee8-4cc2-897d-bda9876c7a94 Netherlands | |
| 42ef1353-9a10-4a2b-be0a-a1f89ccbbcae Poland | |
| bbf539fa-aa6e-464f-833c-291ed8760246 Poland | |
| c833cc95-df64-4654-b0e5-839bac8eed4e Germany | |
| 42ef1353-9a10-4a2b-be0a-a1f89ccbbcae Poland | |
| e9c073b6-6bdb-4b1e-8cad-3650bfc09e84 Belgium | |
| 62c4a5b3-6fbb-4814-aa0d-a1ab4e1300e8 Croatia | |
| 5bd5969e-bbf5-41e8-9abd-5972b2e0add3 Greece | |
| 11c37535-1dcc-4678-a704-a2832dc696f8 Denmark | |
| 734d3f50-4f6b-45a3-9f51-e0aa7a423b76 Germany | |
| 5ed9c6a5-7772-4c77-bc9e-0b0e085af61c Germany | |
| 55850459-c539-4289-9e66-79992e747e39 Belgium | |
| e9c073b6-6bdb-4b1e-8cad-3650bfc09e84 Belgium | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1BSEJAB000A000000XX |
| EAN | 8015644760625 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 278 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 18 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8015644760625 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0024 |
| Technical | |
| Connecting Capacity | 1200 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 3000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 400 W |
| Rated Current (In) | 1600 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1600 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 1600 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 42 kA |
| Overload release current setting (EF002336) | 1600 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 16000 A |
| Adjustment range undelayed short-circuit release (EF007131) | 2400.0 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Connection at separate chassis part |
| Device construction (EF008240) | Built-in device slide-in technique (withdrawable) |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Connection at separate chassis part |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E1.2B 1600 Ekip Dip LSI 3p WMP - ABB - E1.2B1600 - 1SDA072212R1 | 89 Kbytes |
![]() |
| E1.2B1600 1SDA072212R1 ABB E1.2B 1600 Ekip Dip LSI 3p WMP | 72 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.