Product successfully added to your shopping cart
1SDA072171R1
ABB
1
E1.2B 1250 Ekip Dip LI 3p WMP
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax" > E1.2
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 2bee3ec7-c989-4dc8-80c8-96ab0db027ad Italy |
| Simplified SCIP | 2c746bc2-7d2b-4d59-af8d-8fc6b52b2b4e Poland |
| 5e542c73-3ce3-4796-a0ce-d9f55df6bb9e Sweden | |
| d15a9308-c6d3-4478-9764-1e0fe5645b20 France | |
| 0cf35209-7460-4b61-8d27-43216107b80c France | |
| c11f59b4-18d6-4631-9287-acf559c7c813 Germany | |
| 58157a7d-3a78-4859-ae3e-af78a96903b7 Hungary | |
| 58157a7d-3a78-4859-ae3e-af78a96903b7 Hungary | |
| 669d8465-cdc9-46c5-becc-64d509cae21e Estonia | |
| dfcde86e-660b-486a-8d19-ef81082adda8 Netherlands | |
| 45fc0917-1074-42f2-9dac-2a41dd735280 Spain | |
| 851a918c-d425-4110-bc71-34743dfcabf5 Greece | |
| 851a918c-d425-4110-bc71-34743dfcabf5 Greece | |
| 0cf35209-7460-4b61-8d27-43216107b80c France | |
| 8c0d0d7c-6282-40a0-a511-35754b9a16b7 Sweden | |
| 669d8465-cdc9-46c5-becc-64d509cae21e Estonia | |
| 412a286d-129b-43bc-842c-21e31a44e724 Portugal | |
| 3648d075-bcdb-458a-b20b-e07a36f121a0 Poland | |
| cdd08f37-a605-4a27-b23c-597a138b65e1 Belgium | |
| f922ffc5-7f78-486b-8c1a-a49384be98f7 Belgium | |
| 21ab8eab-69db-4404-9fd5-533e0286f592 Poland | |
| dfcde86e-660b-486a-8d19-ef81082adda8 Netherlands | |
| fc8c3dae-7567-4763-8fcf-508f5dbe02b4 Croatia | |
| 1ae6d7c1-e98a-48df-84e4-da9e5c053e0f Denmark | |
| a45849e7-892e-4b4e-9b03-37d501ff5448 Germany | |
| 84e3e4b8-6c23-4d70-a7ac-88a12bc96ac5 Norway | |
| 84e3e4b8-6c23-4d70-a7ac-88a12bc96ac5 Norway | |
| 3648d075-bcdb-458a-b20b-e07a36f121a0 Poland | |
| fc8c3dae-7567-4763-8fcf-508f5dbe02b4 Croatia | |
| f922ffc5-7f78-486b-8c1a-a49384be98f7 Belgium | |
| 8d8b0261-4e9a-483d-9c08-fbad7cbc7344 Germany | |
| bf2e1ac7-9e97-40fc-992b-d4c0166040bc Germany | |
| 2c746bc2-7d2b-4d59-af8d-8fc6b52b2b4e Poland | |
| a45849e7-892e-4b4e-9b03-37d501ff5448 Germany | |
| 21ab8eab-69db-4404-9fd5-533e0286f592 Poland | |
| 35c0e482-e1ef-4402-bec8-387c6a65f8f8 Germany | |
| 8c0d0d7c-6282-40a0-a511-35754b9a16b7 Sweden | |
| 4b732c55-ff30-4fa1-bd82-de88bbbc9d84 Finland | |
| bf2e1ac7-9e97-40fc-992b-d4c0166040bc Germany | |
| 1ae6d7c1-e98a-48df-84e4-da9e5c053e0f Denmark | |
| 45fc0917-1074-42f2-9dac-2a41dd735280 Spain | |
| cdd08f37-a605-4a27-b23c-597a138b65e1 Belgium | |
| c11f59b4-18d6-4631-9287-acf559c7c813 Germany | |
| 6b0a895a-317f-4616-85f4-db71ad9dcd72 Hungary | |
| 6b0a895a-317f-4616-85f4-db71ad9dcd72 Hungary | |
| 4b732c55-ff30-4fa1-bd82-de88bbbc9d84 Finland | |
| 9368b068-d2f5-4195-88e1-5c1005b91637 Czech Republic | |
| d15a9308-c6d3-4478-9764-1e0fe5645b20 France | |
| 412a286d-129b-43bc-842c-21e31a44e724 Portugal | |
| 35c0e482-e1ef-4402-bec8-387c6a65f8f8 Germany | |
| db74e2de-185f-4eda-a34e-be7d157cedb5 Bulgaria | |
| 8d8b0261-4e9a-483d-9c08-fbad7cbc7344 Germany | |
| 9368b068-d2f5-4195-88e1-5c1005b91637 Czech Republic | |
| db74e2de-185f-4eda-a34e-be7d157cedb5 Bulgaria | |
| 5e542c73-3ce3-4796-a0ce-d9f55df6bb9e Sweden | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1BREHAA000A000000XX |
| EAN | 8015644760212 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 278 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 18 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8015644760212 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0024 |
| Technical | |
| Connecting Capacity | 1000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 244 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LI |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 1250 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 42 kA |
| Overload release current setting (EF002336) | 1250 A |
| Adjustment range undelayed short-circuit release (EF007131) | 1875.0 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Connection at separate chassis part |
| Device construction (EF008240) | Built-in device slide-in technique (withdrawable) |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Connection at separate chassis part |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E1.2B 1250 Ekip Dip LI 3p WMP - ABB - E1.2B1250 - 1SDA072171R1 | 89 Kbytes |
![]() |
| E1.2B1250 1SDA072171R1 ABB E1.2B 1250 Ekip Dip LI 3p WMP | 72 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.