Residual Current Circuit Breaker with Overcurrent Protection DS203NC - 3P+N - 30 mA - 32 A - K - Type A

More details


Circuit breakers and fuses > Earth leakage circuit breaker

Tertiary / Industrial

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $193.15
Unit price: $193.15
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



ABB EcoSolutions
ABB EcoSolutionsYes
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 83.26 %
Sustainable Material Content in Packaging (wt. %)Recycled Paper - 00 %
Recycled Cardboard - 92 %
Recycled Paper - 00 %
Extended Product LifetimeProduct Durability
End Of Life Disassembling Instructions9AKK108469A7475
Environmental Product Declaration - EPD9AKK108469A9830
Technical
Type of Residual CurrentType A
Rated Ultimate Short-Circuit Breaking Capacity (Icu)10 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics)6 kA
Power Supply ConnectionArbitrary
Energy Limiting Class3
Electrical Endurance10000 cycle
Mechanical Endurance20000 cycle
Number of Protected Poles3
Number of Poles3P+N
Operating CharacteristicInstantaneous
Position of Neutral TerminalsRight
Earthing Switch TypeUndelayed
Options ProvidedNone
Accessories AvailableYes
Connecting CapacityBusbar 10 mm²
Rigid 25 ... 25 mm²
Flexible 25 ... 25 mm²
Rated Cross-Section1 - Solid-Core 25 … 25 mm²
4 - Multi-Wired 1 … 25 mm²
Electrical
Tripping CharacteristicK
Rated Operational Voltageacc. to IEC 60898-1 415 V
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 500 V
Rated Impulse Withstand Voltage (Uimp)4 kV
Input Voltage TypeAC
Rated Current (In)32 A
Rated Residual Current30 mA
Rated Short-Circuit Capacity6 kA
Rated Conditional Short-Circuit Current (Inc)10 kA
Rated Frequency (f)50/60 Hz
Power Loss15.1 W
Overvoltage CategoryIII
Material Compliance
RoHS Declaration9AKK106713A5597
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Date20211115
REACH Declaration9AKK108467A9482
REACH InformationTrue - contains substances > 0.1 mass percentage
REACH Date20240429
Conflict Minerals Reporting Template (CMRT)9AKK108468A3363
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2BBusiness To Consumer
Environmental
Ambient Air TemperatureOperation -25 … 55 °C
Degree of ProtectionIP2X
Pollution Degree2
Environmental Informationrefer to RoHS information
Dimensions
Width in Number of Modular Spacings4
Product Net Width71 mm
Product Net Height85 mm
Product Net Depth / Length69 mm
Product Net Weight480 g
Built-In Depth (t2)69 mm
Engineering
EPLAN Data9AAC181438_EPLAN
Ordering
Package Level 1 Unitsbox 1 piece
Package Level 1 Gross Weight0.530 kg
E-Number (Norway)1683629
E-Number (Sweden)2160045
Certificates and Declarations
CCC Certificate2021980307001650
Declaration of Conformity - CE9AKK106713A5597
Installation
Instructions and Manuals9AKK106713A8790
Popular Downloads
Data Sheet, Technical Information2CSC423030B0201
External Classifications and Standards
ETIM 9EC000905 - Earth leakage circuit breaker
ETIM 10EC000905 - Earth leakage circuit breaker
UNSPSC39121601
eClassV11.0 : 27142207
IDEA Granular Category Code (IGCC)4875 >> Residual current circuit breaker (RCCB)
Object Classification CodeF
StandardsIEC 61009-1
IEC 61009-2-1
EN 61009-1
EN 61009-2-1

ETIM for 2CSR256140R1327 Circuit breakers and fuses (EC000905)
Feature Name Feature Value
Number of poles (total) (EF008618) 4
Number of protected poles (EF005548) 3
Rated voltage (EF000228) 415 V
Rated insulation voltage Ui (EF001366) 500 V
Rated impulse withstand voltage Uimp (EF011980) 4 kV
Rated current (EF000227) 32 A
Rated fault current (EF002358) 0.03 A
Leakage current type (EF002560) A
Current limiting class (EF002568) 3
Rated short-circuit breaking capacity according to EN 61009 (EF012628) 6 kA
Rated short-circuit breaking capacity according to IEC 60947-2 (EF006065) 10 kA
Rated short-circuit breaking capacity Icn according to EN 61009-1 (EF011981) 6 kA
Disconnection characteristic (EF012587) Undelayed
Voltage type (EF000187) AC
Frequency (EF005455) 50/60 Hz
Release characteristic (EF000889) K
Concurrently switching neutral conductor (EF005997) Yes
With interlocking device (EF007385) Yes
Over voltage category (EF002569) 3
Pollution degree (EF002570) 2
Ambient temperature during operating (EF007515) -25 °C
Width in number of modular spacings (EF002950) 4
Built-in depth (EF000218) 69 mm
Anti-nuisance tripping version (EF009497) No
Degree of protection (IP) (EF005474) IP2X
Connectable conductor cross section solid-core (EF007337) 25 mm²
Connectable conductor cross section multi-wired (EF007343) 25 mm²

Datasheet - PDF

Title: Size: Type:
PDF MINIATURE CIRCUIT BREAKERS EN .pdf 37 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.