Product successfully added to your shopping cart
1SDA121138R1
ABB
1
E4.2H/E12 2500 Ekip Dip LSI 3p WMP
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax"
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2363 |
| Environmental Product Declaration - EPD | 9AKK108471A0821 |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 006d9d6e-07d7-4733-bc0a-e9dc46be367f China |
| Simplified SCIP | 1d40c801-d202-4301-b3e3-7ecfb058215d Portugal |
| f917fc7a-9b1d-4f56-8ce4-b03137d43659 France | |
| 5306d68a-5515-42b5-bcba-3b55489cc4db Germany | |
| bf2750ff-ccca-4641-9d5c-02041270887b Germany | |
| ce62b81f-636a-4243-bb15-6199b8fbab64 Belgium | |
| 3a0f83a2-78aa-4860-b778-8dec25c914bd Finland | |
| 810986c0-519b-4cbe-8be5-c1f63ec3563c Sweden | |
| 9ec5cf1e-8394-4356-836e-cd2be195d3ad Germany | |
| 54239f5c-8d3c-46b9-934f-0c527825958e Bulgaria | |
| 3afb0aa0-4985-4ff9-b91f-683a43270a1a Estonia | |
| 2b9b11c1-6c06-4efb-8b5b-dfd2239a6c55 Poland | |
| bca8d8f6-f509-46dd-85ec-83134aa398d5 Hungary | |
| 410fb0b4-99ba-438e-9585-57b880cd9979 Croatia | |
| 7131ca3b-ad96-4ea1-9799-025addabf88f Norway | |
| bb7507b0-c1af-4559-8ed0-72b71686146f Hungary | |
| 9c7e8220-d766-44c0-b39f-b0ea47c19545 Greece | |
| cb0c0e2f-2d95-425b-a561-838da558a86a Germany | |
| f2d82b22-435c-4dff-b33a-01ad4f6ee65a Belgium | |
| 74c1cf24-5188-4fa4-9f65-c1951966a2d9 Poland | |
| 8ba75e50-fa50-4c2e-ac91-f2db141f7c62 France | |
| edf126dd-96b8-4b8d-bc77-d12d9a88717c Spain | |
| f95ad676-173b-4915-a980-6d91e7fd023e Sweden | |
| 54bb07d4-c2dc-4354-8f15-5e1084b99732 Czech Republic | |
| e1737fa1-5bcf-48b5-8a31-c10a34af8a3f Germany | |
| eccd5ffc-71cd-4ead-a98b-e5463a5291c1 Poland | |
| d610a955-b14d-4ee6-bc75-eb75caffc719 Netherlands | |
| e4f1f4c9-70e8-4aa7-9dd9-475a3f36db43 Denmark | |
| Environmental | |
| Environmental Information | 1SDL000197R0003 |
| 9AKK108467A6707 | |
| Ordering | |
| EAN | 8056221157308 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 425 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 60 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 95 kg |
| Package Level 1 EAN | 8056221157308 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue = 1200 V 1000 cycle |
| 10 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 743 W |
| Rated Current (In) | 2500 A |
| Rated Impulse Withstand Voltage (Uimp) | 15 kV |
| Rated Insulation Voltage (Ui) | 1500 V |
| Rated Operational Voltage | 1200 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (1000 V AC) 85 kA |
| (1150 V AC) 65 kA | |
| (1200 V AC) 50 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 85 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (1000 V AC) 85 kA |
| (1150 V AC) 65 kA | |
| (1200 V AC) 65 kA | |
| Rated Uninterrupted Current (Iu) | 2500 A |
| Rated Voltage (Ur) | 1200 V |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Remarks | E12 |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E4.2 |
| Suitable for IT Networks | No |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200074B0201 |
| 1SDC200023D0209 | |
| Declaration of Conformity - CE | 9AKK107680A4889 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Instructions and Manuals | 1SDH001000R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| 1SDA121138R1 EN_1SDA121138R1.pdf | 91 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.