Product successfully added to your shopping cart
1SDA121106R1
ABB
1
E4.2S/E12 3200 Ekip Dip LSIG 3p FHR
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax"
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2363 |
| Environmental Product Declaration - EPD | 9AKK108471A0821 |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 586dff72-1caa-40f1-ba36-8464de7f9c9c China |
| Simplified SCIP | a3d8ea3a-6b5d-4f49-a701-51b078880ce2 France |
| e4fa9851-07ca-4cae-b38e-3292a6033b88 Sweden | |
| b1730a9b-cee1-4ac8-ba85-d4d6b73a22bc Poland | |
| 397b1872-2ba7-4053-a9f9-5ce0869b9010 Sweden | |
| 46c84c84-6112-45b6-826f-a0569560a800 Germany | |
| c790cf50-4e25-4903-b5fb-212652795917 Germany | |
| 5419ac49-83cb-49e7-be54-706feddd6ef1 Belgium | |
| 46332fd3-1931-4d77-a38a-02fc8a270b95 Finland | |
| 62eec89a-3a2b-4c3a-84b2-80d7e9a81b25 Germany | |
| 0d09ac1b-1635-4112-be7d-9dc2434a005d France | |
| 03393bc1-cd42-40a0-88c2-f726ed735db7 Hungary | |
| af5cf496-6a8f-4316-ae73-684ed90a8837 Estonia | |
| db6103d9-7ccc-4881-86ad-72eceacea685 Poland | |
| b291189e-72d1-4e4d-b9c1-8bdc15e03695 Bulgaria | |
| 880e99f9-c969-402a-83e6-85ab313fbc5f Germany | |
| b498be01-0598-4175-a38d-ae2229a85032 Portugal | |
| 5988e6b7-05ad-499e-a601-bde8aae701ac Greece | |
| 2bfa2730-4d71-445c-87ef-4a4409bb1058 Croatia | |
| f73a0382-6db5-4e4f-a469-0c1afa73f73d Hungary | |
| 36616b38-34e2-4651-b686-f4bb35647c47 Denmark | |
| 7e41ff16-915e-44f1-9082-ad0e23a51bd2 Norway | |
| 427da06e-720a-43d9-ab5f-23bf7d87811a Spain | |
| eabb6c4a-e9f5-442b-b7fd-9472a883b56d Belgium | |
| 70758294-e605-43cc-9a7d-dd6ec4eebeec Germany | |
| ad36f82f-a82b-4d73-9759-215ec647cbda Czech Republic | |
| d0c16b8a-3628-4257-85a5-b16c25465cf0 Poland | |
| 99847216-de6c-4e45-821b-4fff4555cca8 Netherlands | |
| Environmental | |
| Environmental Information | 1SDL000197R0003 |
| 9AKK108467A6707 | |
| Ordering | |
| EAN | 8056221156981 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 384 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 56 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 785 mm |
| Package Level 1 Gross Weight | 95 kg |
| Package Level 1 EAN | 8056221156981 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue = 1200 V 1000 cycle |
| 10 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 425 W |
| Rated Current (In) | 3200 A |
| Rated Impulse Withstand Voltage (Uimp) | 15 kV |
| Rated Insulation Voltage (Ui) | 1500 V |
| Rated Operational Voltage | 1200 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (1000 V AC) 65 kA |
| (1150 V AC) 50 kA | |
| (1200 V AC) 50 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 65 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (1000 V AC) 65 kA |
| (1150 V AC) 50 kA | |
| (1200 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 3200 A |
| Rated Voltage (Ur) | 1200 V |
| Release | Ekip Dip LSIG |
| Release Type | EL |
| Remarks | E12 |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E4.2 |
| Suitable for IT Networks | Yes, 800V |
| Terminal Connection Type | Rear flat Horizontal |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200074B0201 |
| 1SDC200023D0209 | |
| Declaration of Conformity - CE | 9AKK107680A4889 |
| Instructions and Manuals | 1SDH001000R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| 1SDA121106R1 EN_1SDA121106R1.pdf | 108 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.