Product successfully added to your shopping cart
1SDA121103R1
ABB
1
E4.2S/E12 2500 Ekip Dip LSIG 3p FHR
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax"
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2363 |
| Environmental Product Declaration - EPD | 9AKK108471A0821 |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | cd2aa1c9-febd-40ab-806d-1b680b935701 China |
| Simplified SCIP | 724015cc-52fd-434b-bf81-e20f69094f94 Poland |
| 6edb2493-e20c-4b78-9e9d-9e14665916be Sweden | |
| 75f79b92-3c32-480e-84a6-556866155f27 France | |
| 4a908741-26a1-422f-acdf-b43f6bdc7f7f Portugal | |
| a0f3ef79-aa50-495b-bd47-cdfe9af87f50 Germany | |
| 21859b5f-eb62-4803-9e8f-d91d71ac57f8 Hungary | |
| 27cb4d76-98b9-4a5e-bffe-441ad1e89bfd Estonia | |
| 7bc92111-8ca1-46f5-af48-ae96ba2f4f94 Poland | |
| 798f0d45-e385-4e30-83f7-5cf02ba24190 Bulgaria | |
| ee841c5a-d93f-49cb-af8e-4efe244c2e72 Belgium | |
| fb269673-f4e3-400f-b9fa-dfdd1cd54de2 Germany | |
| 480aeaf6-07ec-4434-8206-d9f0d37860cc Spain | |
| 10004a12-877c-439b-832b-2c1e5e1389f4 Hungary | |
| a427bb35-4e12-486f-9c24-8045600cedc6 Croatia | |
| 09354de9-2901-45ff-b5ed-058c1028e7a8 Poland | |
| 5eaef8b8-b7fa-42d9-af80-10e404920758 Netherlands | |
| fe47f5be-cb54-482b-adad-61d8aa979512 Czech Republic | |
| 193524dc-042c-4bbb-9344-a11f3caa536d Belgium | |
| 469885d5-26fe-4bef-9bf5-8098905343ec Germany | |
| cbf19a9e-3b2e-4351-95f3-2918a45f980a France | |
| ec4b643e-f1a4-46d6-b4f7-71ff846bfaec Finland | |
| 4ce9f459-5831-4ad8-8754-38d83ffbdd48 Germany | |
| cb44efb6-45b7-4216-8790-b6b8023ed884 Greece | |
| a6640dc1-f9d8-43db-870c-e85e1735d015 Denmark | |
| cbe9a5bd-ffa2-4b32-9088-1d1590ce0ab8 Norway | |
| 13156c64-1a61-4957-9794-56b01def4763 Sweden | |
| 31617fde-013b-4c7e-9f0a-f33be6e06f2e Germany | |
| Environmental | |
| Environmental Information | 1SDL000197R0003 |
| 9AKK108467A6707 | |
| Ordering | |
| EAN | 8056221156950 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 384 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 56 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 785 mm |
| Package Level 1 Gross Weight | 95 kg |
| Package Level 1 EAN | 8056221156950 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue = 1200 V 1000 cycle |
| 10 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 425 W |
| Rated Current (In) | 2500 A |
| Rated Impulse Withstand Voltage (Uimp) | 15 kV |
| Rated Insulation Voltage (Ui) | 1500 V |
| Rated Operational Voltage | 1200 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (1000 V AC) 65 kA |
| (1150 V AC) 50 kA | |
| (1200 V AC) 50 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 65 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (1000 V AC) 65 kA |
| (1150 V AC) 50 kA | |
| (1200 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 2500 A |
| Rated Voltage (Ur) | 1200 V |
| Release | Ekip Dip LSIG |
| Release Type | EL |
| Remarks | E12 |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E4.2 |
| Suitable for IT Networks | Yes, 800V |
| Terminal Connection Type | Rear flat Horizontal |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200074B0201 |
| 1SDC200023D0209 | |
| Declaration of Conformity - CE | 9AKK107680A4889 |
| Instructions and Manuals | 1SDH001000R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| 1SDA121103R1 EN_1SDA121103R1.pdf | 108 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.