1SDA104609R1
ABB
1
E6.2H/E9 5000 Ekip Touch LSI 3p FHR
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax"
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2364 |
| Environmental Product Declaration - EPD | 9AKK108471A0821 |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 3ec50516-b17b-477f-92da-648d9fc855d9 Italy |
| Simplified SCIP | 52a523c5-d76e-46dd-917f-d030eccd6a1d Poland |
| d6244f6f-b18a-4715-8fff-83d448bd54d1 Croatia | |
| c4b4fc78-8fa2-4baf-8059-89840a9f9ab3 Germany | |
| 3e15ca43-18c8-4d94-b641-663574b3a9b3 Poland | |
| 884de41e-126b-4e01-8769-21de11013c0e Belgium | |
| 706af7e9-914d-494c-9f07-6a3e8a559021 Denmark | |
| fcf94b1b-c9b2-4827-896b-2d1ba3e73dbb Germany | |
| 413f1db7-1c76-4981-8d56-ba1feec14514 Belgium | |
| 70725b84-a8d3-4867-86f9-c63fb222d3b6 Germany | |
| 36c2799a-2ea2-4c35-a254-9a5fbf1cbdbc Hungary | |
| d79cfd68-8808-4b14-8d6f-28ccf525e45f Spain | |
| 422225be-4b62-4d61-a3d2-dd033f983231 France | |
| 3496d41d-bbda-4626-9fb5-f24dae02ac5f Germany | |
| 572cc768-8b67-4ed2-8131-4a3e0e473ac8 Sweden | |
| 40a9dc45-679d-44aa-ab65-271ea4516e1c Finland | |
| e0cd9324-11f1-41c7-87f1-36a0c6736093 Norway | |
| beed054e-3942-42b5-b599-21ac190a4a3d Germany | |
| 44686899-6d72-4ee3-a850-32cebd1a660c Poland | |
| 584f9880-bff2-46a5-85c7-b999bf3081a7 Hungary | |
| 2082a825-457d-48e0-b04b-56437fdc040d Netherlands | |
| e549ed80-4166-459e-96e2-bd80286ee805 Estonia | |
| c6789186-6c67-4c8c-8a5b-742359058a59 Greece | |
| 5c85cb02-3590-49d1-8dff-a33cf90d25bd Portugal | |
| 5732149e-dcc7-4a34-8ddb-28709429f766 Bulgaria | |
| 0b49ac8c-fa68-46a7-98e7-3c6176ed5c35 Sweden | |
| 0fcbc2a9-ea97-41dd-9d15-935a33541b58 Czech Republic | |
| 672ed50b-e4af-4295-af08-92157f190e01 France | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | 96HXESBE000A000000XX |
| EAN | 8015644066895 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 762 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 109 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 1000 mm |
| Package Level 1 Gross Weight | 129 kg |
| Package Level 1 EAN | 8015644066895 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue = 900 V 1000 cycle |
| 10 cycles per hour | |
| Mechanical Durability | 12000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 483 W |
| Rated Current (In) | 5000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 900 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (800 V AC) 90 kA |
| (900 V AC) 75 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 75 kA |
| for 3 s 66 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (800 V AC) 90 kA |
| (900 V AC) 75 kA | |
| Rated Uninterrupted Current (Iu) | 5000 A |
| Rated Voltage (Ur) | 900 V |
| Release | Ekip Touch LSI |
| Release Type | EL |
| Remarks | E9 |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E6.2 |
| Suitable for IT Networks | No |
| Terminal Connection Type | Rear flat Horizontal |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK107680A4890 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| 1SDA104609R1 1SDA104609R1 EN_1SDA104609R1.pdf | 93 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.