Product successfully added to your shopping cart
1SDA104465R1
ABB
1
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax"
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108471A0821 |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 149700c6-cb7b-4680-9a9b-399dc7d71944 Italy |
| Simplified SCIP | 73a64c4b-9f9d-468c-a09b-0f2d1a7891b8 Czech Republic |
| a92d4ab3-2568-4a82-842f-891892eb4214 Netherlands | |
| 90b22909-78e3-41d8-91a9-f9016255395b Poland | |
| 6fc298fb-23cc-43bd-ae54-fda9ebde00c9 Belgium | |
| d38547c2-9faf-4717-bc9c-8b9e1dfc196b Hungary | |
| 40ee5748-f5ac-42f1-a5e2-f412a0184260 France | |
| 19b0118b-a70e-485a-b36e-539656b6137f Sweden | |
| 4df79a63-639c-40c3-b6a5-16fd9cfb01a8 Germany | |
| b35d7fdd-6028-4610-ab44-2a7ad7e3e8ce Germany | |
| c7a52a14-19b8-4799-8792-8512aea227ad France | |
| 3ef0ee5d-c30f-4beb-92b3-466eae37eacf Germany | |
| 44e97cc1-d644-4b80-87d2-f083bbad2b8d Norway | |
| fb8130ff-93e9-4040-9b5b-e29290a58f4c Poland | |
| 2844d050-0027-4666-8761-b4a86b4247f4 Spain | |
| f99c40fd-cfb5-4c1c-9561-957ea80e482e Poland | |
| 26a910c7-d4b2-41a7-b65c-6d8a27169dc9 Sweden | |
| a6c934d4-1c53-431a-9867-d34054680f0f Finland | |
| 43e66443-151d-401f-a667-dab5b02e15c6 Belgium | |
| dc8a151a-a6c5-4e9f-bf14-6f8d03d6930d Germany | |
| 7c496acd-ade3-45d6-a00c-b38569174ceb Germany | |
| b6e79e68-0154-4ada-a430-c0b3bbd7ccf1 Denmark | |
| 7535655d-ff8f-4b05-be28-03651a834b6f Portugal | |
| 8f9e7f1b-305b-4c62-9256-97ec91140629 Croatia | |
| a3628979-9a3e-4b66-a62e-c0b4aa7502ed Greece | |
| 82489985-bee2-446f-bc24-c80d0ef89a85 Bulgaria | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | 9BSUELAK200A000000XX |
| EAN | 8015644065454 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 407 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 55 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 64 kg |
| Package Level 1 EAN | 8015644065454 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue = 900 V 2000 cycle |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 4P |
| Power Loss | 550 W |
| Rated Current (In) | 2500 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 900 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (800 V AC) 50 kA |
| (900 V AC) 50 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kA |
| for 3 s 50 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (800 V AC) 50 kA |
| (900 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 2500 A |
| Rated Voltage (Ur) | 900 V |
| Release | Ekip Hi-Touch LSIG |
| Release Type | EL |
| Remarks | E9 |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 900V |
| Terminal Connection Type | Rear flat Horizontal |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK107680A4888 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 2500 A |
| Rated voltage (EF003977) | 900 V |
| Overload release current setting (EF002336) | 1000.0 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 1500.0 A |
| Adjustment range undelayed short-circuit release (EF007131) | 3750.0 A |
| Integrated earth fault protection (EF007296) | Yes |
| Type of electrical connection of main circuit (EF006819) | Connection at separate chassis part |
| Device construction (EF008240) | Built-in device slide-in technique (withdrawable) |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 4 |
| Position of connection for main current circuit (EF006671) | Connection at separate chassis part |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| 1SDA104465R1 1SDA104465R1 EN_1SDA104465R1.pdf | 88 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.