Product successfully added to your shopping cart
1SDA104364R1
ABB
1
E2.2H/E9 1250 Ekip Touch LSIG 4p FHR
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax"
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108471A0821 |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 7585aced-0d51-4d89-8d8f-26c46f5be803 Italy |
| Simplified SCIP | 180c4b44-28d5-4956-a219-b4230e3bba96 Sweden |
| 5e02811d-f9a9-46a8-a736-ebf3e05c3786 Spain | |
| 4625b290-5d9e-4890-852a-338340a6ef65 Belgium | |
| bd0b0d82-ad90-4699-a31d-da3d4f5467a8 Poland | |
| 97e88def-d6e9-480f-b1f2-a826df050d52 France | |
| adb8357a-0706-4d6b-955c-bfd87ef4c7ab Germany | |
| f42b557a-2b13-4d5c-b581-38cec9ee2374 Norway | |
| f6986916-c17c-4528-ac20-acffcddb937a Poland | |
| 771fa4d0-aed2-4764-bdcb-5d436906d02d Hungary | |
| 5c730db2-101c-4fdb-a798-4a85407f7e42 France | |
| 52c923be-235b-4af8-ae53-0d9345934819 Germany | |
| b4706159-8729-4505-bc32-2a68f758c5cb Sweden | |
| f078a485-d0a5-4af2-83a7-6f568d498a57 Netherlands | |
| 495904d6-27bd-48e9-8d2a-1c3a4377e808 Poland | |
| 4264c093-a073-4375-8ee2-233592fa4cb2 Bulgaria | |
| 08464fbb-9dbc-4cd5-989c-2b06bb17f5ae Greece | |
| 58aef178-0636-4e80-b3de-ab3356061fb2 Croatia | |
| f83e2068-31c6-4793-b28d-2d538b2349c6 Portugal | |
| 8707ead1-283b-4f3d-832f-c73c32fb40d0 Czech Republic | |
| 8f2f86c9-be01-412b-9c99-efddacd0a88c Germany | |
| a9635884-7366-4dc6-8014-d0334e36119e Finland | |
| af02e10d-2bff-4936-be55-3ba53f019b8e Belgium | |
| ff8a80a7-21d1-4cbf-bb95-b834d1471ad1 Denmark | |
| 9c5c33c7-9b9d-48c5-b48d-d1799a7ff83c Germany | |
| 3ca55ca3-9e1c-4b7a-ab00-f583ffabc7b8 Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | 9BHREHBF000A000000XX |
| EAN | 8015644064440 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 366 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 53 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 53 kg |
| Package Level 1 EAN | 8015644064440 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue = 900 V 2000 cycle |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 4P |
| Power Loss | 83 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 900 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (800 V AC) 65 kA |
| (900 V AC) 65 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 65 kA |
| for 3 s 65 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (800 V AC) 65 kA |
| (900 V AC) 65 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 900 V |
| Release | Ekip Touch LSIG |
| Release Type | EL |
| Remarks | E9 |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 900V |
| Terminal Connection Type | Rear flat Horizontal |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK107680A4888 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| 1SDA104364R1 1SDA104364R1 EN_1SDA104364R1.pdf | 87 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.