Product successfully added to your shopping cart
1SDA104363R1
ABB
1
E2.2H/E9 1250 Ekip Dip LSIG 4p FHR
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax"
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108471A0821 |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 40913f01-2895-4636-9124-028d367c4577 India |
| Simplified SCIP | 626fe1ba-7830-4fb3-8d78-e2d4302e0868 France |
| 42a32ec1-4223-418e-bafd-cf7db2268739 Poland | |
| f1e90dca-7563-468e-b95a-8aeaf4398a34 Czech Republic | |
| 00f9d66b-1919-401c-baa3-671fe25eb55d Croatia | |
| 1d19cfed-2123-4c55-a35a-738488d0dc9e Finland | |
| d41853a5-d7a4-4ee3-88ff-93b1c87b8f1f Belgium | |
| a0343eea-bcd7-4be0-84c5-fc008928dbe1 Hungary | |
| 3b7fe0cf-ac00-408f-af4c-d8cec0d9aeb0 Spain | |
| 909ed79c-621a-4357-85bb-92a75f52b0b7 France | |
| 0a31890d-ec10-4c56-a31f-39c002176761 Denmark | |
| 34ac542f-1333-4440-b508-77521ec69819 Germany | |
| c1719e11-6295-481a-982f-85df6f213409 Netherlands | |
| 53bc3d00-801c-41c2-af25-f4597c2b43b1 Hungary | |
| 4d2fba69-adf9-4df4-aca0-21db5ae87bbe Portugal | |
| b63ed36a-4ac7-41f0-8943-74510792e0da Germany | |
| 927250e7-166a-456f-9c83-c04e446592ff Sweden | |
| eedcadee-21b7-4a2f-a7eb-dfaca918d63b Germany | |
| 11dcb2bc-196a-47c2-bb84-b10c4f71c4f4 Sweden | |
| 624909b1-5649-4fc7-9cc5-6d0fe8e78827 Bulgaria | |
| 50f0a5be-03b8-48c5-a495-f264dcb06e18 Poland | |
| a57b6b0a-8df5-49fb-9fe4-4598808d42d1 Estonia | |
| 2ee58b59-16d7-40c3-828e-e01a6b9263ba Greece | |
| 148ba9c8-b96a-446c-97ad-b6fe6db45dbb Germany | |
| 66eb34af-4823-4912-946f-9e758cc6c695 Poland | |
| 970d6eb7-b37a-4cda-a03e-dce800787cd5 Belgium | |
| ab5d3438-c974-4b45-822c-ddbd776f243f Norway | |
| bcf19f03-3f58-40e7-89bd-b87e9c4a8edf Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | 9BHREHBC000A000000XX |
| EAN | 8015644064433 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 366 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 53 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 53 kg |
| Package Level 1 EAN | 8015644064433 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue = 900 V 2000 cycle |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 4P |
| Power Loss | 83 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 900 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (800 V AC) 65 kA |
| (900 V AC) 65 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 65 kA |
| for 3 s 65 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (800 V AC) 65 kA |
| (900 V AC) 65 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 900 V |
| Release | Ekip Dip LSIG |
| Release Type | EL |
| Remarks | E9 |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 900V |
| Terminal Connection Type | Rear flat Horizontal |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK107680A4888 |
| Instructions and Manuals | 1SDH001000R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| 1SDA104363R1 1SDA104363R1 EN_1SDA104363R1.pdf | 87 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.