Product successfully added to your shopping cart
1SDA104349R1
ABB
1
E2.2H/E9 1250 Ekip Touch LSIG 3p FHR
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax"
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108471A0821 |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 1554dce9-9ce2-4905-a027-b5222fb039b7 Italy |
| Simplified SCIP | 91c03837-7ab5-46cc-9413-aec5bf77f59b Germany |
| 88f7d5f1-540f-4341-8a8d-1314c34333ac France | |
| b854a336-bd67-443a-a0eb-c60acfc89d4e Portugal | |
| 6e5e213e-f81c-4b55-aaeb-b5f9444ef6a4 Greece | |
| 75056d60-f93f-416e-a416-926410c29835 Croatia | |
| 3bdd57b7-ff49-4a18-8020-f53f836536d3 Sweden | |
| c8f84f77-f902-42d5-aeb0-4199966c7ef3 Bulgaria | |
| 7c26a6f3-1015-435c-bbc6-331d2f495a0b Netherlands | |
| 03097683-7677-4169-b02b-e9e634d9519f Spain | |
| 2de50a77-0543-4130-baf1-613d2139b52e Belgium | |
| 04496049-5492-4120-8fb9-50d806f2e7bd Hungary | |
| 1afb59d1-8dd5-42a4-9258-248b36162bfd France | |
| a0e0eb74-a8bc-498c-9aa0-d6ed98822b06 Finland | |
| 553f8a61-ef7e-4d5b-ae73-98ef1d7d4d1a Poland | |
| ff2a5ce7-246d-4efe-a639-05c2bfd8fc0d Hungary | |
| cdf5266f-bc81-47e0-8f7c-e60b84a2cd90 Norway | |
| e5dcb942-30c3-4cc5-b3d2-36a369a11667 Estonia | |
| 652c7282-1c23-408f-9961-e5a9ec5f5e2e Germany | |
| 4c27d9d8-b77b-43fb-9a4d-39a64e745dcb Denmark | |
| c62b5fde-2ffe-47c8-9064-ce8de885daa7 Germany | |
| bfbff277-8247-46dd-ae93-99e3bc34048a Germany | |
| dc744007-e52d-45c2-a4da-3b35f1c3fe8b Germany | |
| ba4a9f79-3af9-48de-8e62-3103a6836d92 Belgium | |
| 1785a378-349f-4e47-8308-1fbd56f5cd9f Sweden | |
| b276ff84-88ab-4c86-817d-a6c5c9a2c7a6 Poland | |
| 275df0bb-d5da-48e6-a951-45ac8a12bd86 Czech Republic | |
| 0ec5f7bf-b093-4b73-afb2-5547854b0b22 Poland | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | 92HREHBF000A000000XX |
| EAN | 8015644064297 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 276 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 41 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 53 kg |
| Package Level 1 EAN | 8015644064297 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue = 900 V 2000 cycle |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 83 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 900 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (800 V AC) 65 kA |
| (900 V AC) 65 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 65 kA |
| for 3 s 65 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (800 V AC) 65 kA |
| (900 V AC) 65 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 900 V |
| Release | Ekip Touch LSIG |
| Release Type | EL |
| Remarks | E9 |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 900V |
| Terminal Connection Type | Rear flat Horizontal |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK107680A4888 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| 1SDA104349R1 1SDA104349R1 EN_1SDA104349R1.pdf | 88 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.