Product successfully added to your shopping cart
1SDA104284R1
ABB
1
E1.2N/E9 1250 Ekip Dip LSI 4p F F
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax"
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108471A0820 |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 96bdbbb6-ccee-4afc-bdb9-8c97eb0d5c96 Italy |
| Simplified SCIP | 4b57fce5-5ba1-4fa1-b5b2-5e89bce39dd2 Belgium |
| 36f8ebb2-3953-4bc3-9f1f-c72e97eb7921 Norway | |
| dcda9528-684b-4e61-a2e4-d6502b8ce4be Belgium | |
| 25dc184f-9f67-468c-bd92-b2052e7677af Denmark | |
| e271e5f4-2ce2-442b-9e6b-051ee6e56b0a Bulgaria | |
| ce5a2a3e-6a2e-43c4-bcba-0441b39fff36 Finland | |
| e6ccaeb9-7205-46b3-a127-d957d1e343c6 Sweden | |
| f7c08a3b-d10a-408e-96d3-b3055d4269e5 Germany | |
| 00277b06-b943-421c-9039-485b77afa06a Estonia | |
| afc92a13-3b34-451b-822a-5a40874e16a1 Poland | |
| f0551e51-d447-4881-887c-e3a8846b1650 Germany | |
| 7b7feea6-e022-4847-9259-5e5fcc57e846 Poland | |
| d852c96c-221b-4a97-affe-af899b9d3224 Poland | |
| 5243503a-19eb-4bc1-9b44-d89ed4f0d335 Hungary | |
| 25dc184f-9f67-468c-bd92-b2052e7677af Denmark | |
| 7e01fc25-ab03-4ac4-88a6-ca0377505c63 Greece | |
| 4b57fce5-5ba1-4fa1-b5b2-5e89bce39dd2 Belgium | |
| 89b0efa7-13d8-4864-8c05-0297585521d7 Croatia | |
| 1f7965f2-6891-4101-ab4a-de48b120f7c7 Germany | |
| 1f7965f2-6891-4101-ab4a-de48b120f7c7 Germany | |
| ce5a2a3e-6a2e-43c4-bcba-0441b39fff36 Finland | |
| df69e78d-60bd-49d7-bfc3-99f3ddb190d1 Portugal | |
| b56e87e5-7892-4c4d-b932-982929f1525c Czech Republic | |
| f7c08a3b-d10a-408e-96d3-b3055d4269e5 Germany | |
| 0e272d5f-26a9-4e66-8002-dc0438cf457f France | |
| f0551e51-d447-4881-887c-e3a8846b1650 Germany | |
| 36f8ebb2-3953-4bc3-9f1f-c72e97eb7921 Norway | |
| e271e5f4-2ce2-442b-9e6b-051ee6e56b0a Bulgaria | |
| c2278937-a627-42a4-9890-23a27cf194ce Germany | |
| b84f715e-a634-4cfd-ac06-f0f644e00317 Sweden | |
| da9c31db-d0e6-4436-8b7a-7ce5c4abd755 Netherlands | |
| 89b0efa7-13d8-4864-8c05-0297585521d7 Croatia | |
| a74999df-d91c-4c81-8850-81caa66edbb3 Hungary | |
| ea654527-ba2d-4514-93ef-0fa02f2e1243 Germany | |
| df69e78d-60bd-49d7-bfc3-99f3ddb190d1 Portugal | |
| afc92a13-3b34-451b-822a-5a40874e16a1 Poland | |
| 7e01fc25-ab03-4ac4-88a6-ca0377505c63 Greece | |
| da9c31db-d0e6-4436-8b7a-7ce5c4abd755 Netherlands | |
| d852c96c-221b-4a97-affe-af899b9d3224 Poland | |
| dcda9528-684b-4e61-a2e4-d6502b8ce4be Belgium | |
| 44fdc62a-0921-4c2a-a4e5-96af2a6a8076 Spain | |
| 5243503a-19eb-4bc1-9b44-d89ed4f0d335 Hungary | |
| c21a7262-bf18-41bf-a184-194ad5436406 France | |
| e6ccaeb9-7205-46b3-a127-d957d1e343c6 Sweden | |
| 44fdc62a-0921-4c2a-a4e5-96af2a6a8076 Spain | |
| 00277b06-b943-421c-9039-485b77afa06a Estonia | |
| 7b7feea6-e022-4847-9259-5e5fcc57e846 Poland | |
| c2278937-a627-42a4-9890-23a27cf194ce Germany | |
| ea654527-ba2d-4514-93ef-0fa02f2e1243 Germany | |
| b84f715e-a634-4cfd-ac06-f0f644e00317 Sweden | |
| 0e272d5f-26a9-4e66-8002-dc0438cf457f France | |
| a74999df-d91c-4c81-8850-81caa66edbb3 Hungary | |
| b56e87e5-7892-4c4d-b932-982929f1525c Czech Republic | |
| c21a7262-bf18-41bf-a184-194ad5436406 France | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | 9ANREHBB000A000000XX |
| EAN | 8056221026079 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 16 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8056221026079 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue = 800 V 500 cycle |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 4P |
| Power Loss | 122 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 800 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (800 V AC) 44 kA |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 44 kA |
| for 3 s 30 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (800 V AC) 50 kA |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 800 V |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Remarks | E9 |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 800V |
| Terminal Connection Type | Rear flat Horizontal |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK108468A2366 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 1250 A |
| Rated voltage (EF003977) | 800 V |
| Overload release current setting (EF002336) | 1250 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 12500 A |
| Adjustment range undelayed short-circuit release (EF007131) | 1875.0 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 4 |
| Position of connection for main current circuit (EF006671) | Back |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.