Produkt wurde in den Korb gelegt
11BG0031A048
BG0031A048
LOVATO ELECTRIC
1
Eigenschaften 48VAC, 3S und 1Ö
Hilfs-Minikontaktor 10A 3 NA 1 NC Spule 48V AC
STEUERRELAIS MIT STEUERKREIS: AC UND DC, TYP BG00, AC-SPULE 50/60HZ, 48VAC, 3NO UND 1NC
Schütze - LOVATO ELECTRIC
* Neues Produkt in der Originalverpackung mit allen Garantien und Zertifizierungen von LOVATO ELECTRIC
Danke für Ihr Interesse an unseren Produkten, wir hoffen die Lieferzeit ist ok.
Während der Bestellung können Sie den für Sie bestmöglichen Versand wählen: Express 24h, Standard 48h/72h, etc.
Bestellnummer | 11BG0031A048 |
Gewicht [g] | 177 |
Produktpaketmenge | 1 |
Sammelpackung Bestellmenge | 1 |
Produktpaketmaße [mm] | 060X045X060 |
Volumen [cm³] | 162 |
Barcode [EAN13] | 8013975081778 |
HS Code | 85365080 |
Product designation | Auxiliary contactor | |||
Product type designation | BG00 | |||
Contact characteristics | ||||
Number of poles | nr. | 4 | ||
Rated insulation voltage Ui IEC/EN | V | 690 | ||
Rated impulse withstand voltage Uimp | kV | 6 | ||
Operational frequency | ||||
min | Hz | 25 | ||
max | Hz | 400 | ||
IEC Conventional free air thermal current Ith | A | 10 | ||
Operational current Ie | ||||
AC-1 (≤40°C) | A | 160 | ||
Short-time allowable current for 10s (IEC/EN60947-1) | A | 0 | ||
Protection fuse | ||||
gG (IEC) | A | 16 | ||
Tightening torque for terminals | ||||
min | Nm | 0.8 | ||
max | Nm | 1 | ||
min | Ibin | 0.59 | ||
max | Ibin | 0.74 | ||
Tightening torque for coil terminal | ||||
min | Nm | 0.8 | ||
max | Nm | 1 | ||
min | Ibft | 0.8 | ||
max | Ibft | 0.74 | ||
Max number of wires simultaneously connectable | nr. | 2 | ||
Conductor section | ||||
Flexible w/o lug conductor section | ||||
min | mm² | 0.75 | ||
max | mm² | 2.5 | ||
Flexible c/w lug conductor section | ||||
min | mm² | 1.5 | ||
max | mm² | 2.5 | ||
Flexible with insulated spade lug conductor section | ||||
min | mm² | 1.5 | ||
max | mm² | 2.5 | ||
Power terminal protection according to IEC/EN 60529 | IP20 when wired | |||
Mechanical features | ||||
Operating position | ||||
normal | vertical plan | |||
allowable | ±30° | |||
Fixing | Screw / DIN rail 35mm | |||
Weight | g | 177 | ||
Auxiliary contact characteristics | ||||
Type of contact | 3 NO + 1 NC | |||
Thermal current Ith | A | 10 | ||
IEC/EN 60947-5-1 designation | A600 - Q600 | |||
Operating current AC15 | ||||
230V | A | 3 | ||
400V | A | 1.9 | ||
500V | A | 1.4 | ||
Operating current DC12 | ||||
110V | A | 2.9 | ||
Operating current DC13 | ||||
24V | A | 2.9 | ||
48V | A | 1.4 | ||
60V | A | 1.2 | ||
110V | A | 0.6 | ||
125V | A | 0.55 | ||
220V | A | 0.3 | ||
600V | A | 0.1 | ||
Operations | ||||
Mechanical life | cycles | 20000000 | ||
Safety related data | ||||
Performance level B10d according to EN/ISO 13489-1 | ||||
mechanical load | cycles | 20000000 | ||
Mirror contats according to IEC/EN 609474-4-1 | true | |||
EMC compatibility | Yes | |||
AC coil operating | ||||
Rated AC voltage at 50/60Hz | V | 48 | ||
AC operating voltage | ||||
of 50/60Hz coil powered at 50Hz | ||||
pick-up | ||||
min | %Us | 75 | ||
max | %Us | 115 | ||
drop-out | ||||
min | %Us | 20 | ||
max | %Us | 55 | ||
of 50/60Hz coil powered at 60Hz | ||||
pick-up | ||||
min | %Us | 80 | ||
max | %Us | 115 | ||
drop-out | ||||
min | %Us | 20 | ||
max | %Us | 55 | ||
AC average coil consumption at 20°C | ||||
of 50/60Hz coil powered at 50Hz | ||||
in-rush | VA | 30 | ||
holding | VA | 4 | ||
of 50/60Hz coil powered at 60Hz | ||||
in-rush | VA | 25 | ||
holding | VA | 3 | ||
of 60Hz coil powered at 60Hz | ||||
in-rush | VA | 30 | ||
holding | VA | 4 | ||
Dissipation at holding ≤20°C 50Hz | W | 0.95 | ||
Max cycles frequency | ||||
Mechanical operation | cycles/h | 3600 | ||
Operating times | ||||
Average time for Us control | ||||
in AC | ||||
Closing NO | ||||
min | ms | 12 | ||
max | ms | 21 | ||
Opening NO | ||||
min | ms | 9 | ||
max | ms | 18 | ||
Closing NC | ||||
min | ms | 17 | ||
max | ms | 26 | ||
Opening NC | ||||
min | ms | 7 | ||
max | ms | 17 | ||
in DC | ||||
Closing NO | ||||
min | ms | 18 | ||
max | ms | 25 | ||
Opening NO | ||||
min | ms | 2 | ||
max | ms | 3 | ||
Closing NC | ||||
min | ms | 3 | ||
max | ms | 5 | ||
Opening NC | ||||
min | ms | 11 | ||
max | ms | 17 | ||
UL technical data | ||||
General USE | ||||
Contactor | ||||
AC current | A | 160 | ||
Contact rating of auxiliary contacts according to UL | A600 - Q600 | |||
Ambient conditions | ||||
Temperature | ||||
Operating temperature | ||||
min | °C | -50 | ||
max | °C | +70 | ||
Storage temperature | ||||
min | °C | -60 | ||
max | °C | +80 | ||
Max altitude | m | 3000 | ||
Resistance & Protection | ||||
Pollution degree | 3 | |||
ETIM classification | ||||
ETIM 8.0 | EC000196 - Contactor relay |
Titel: | Größe: | Typ: |
---|---|---|
11BG0031A048 BG0031A048 02-Sch_tze-02-Januar-2018_DE.pdf | 6 Mbytes |
Es gibt keine Produktbewertungenvor.
Wertung: | |
Name: | |
E-Mail : | |
Betreff: | |
Text: | |
Haben Sie dieses Produkt empfehlen zu kaufen? | |
Bewertung abgeben |
Alle Bewertungen wir von den Einzelteilen erhalten wir anbieten, sind real und verifiziert. Eine kleine Geste, aber sehr wertvoll. Also danke für die Minute, die Sie in, dass Sie uns Ihre Meinung und Bewertung von Produkten ausgeben, weil es mir hilft, weiter zu verbessern und noch mehr Servicequalität zu bieten.