Product successfully added to your shopping cart
QUINT-UPS/ 1AC/ 1AC/500VA
2320270
PHOENIX_CONTACT
1
Uninterruptible power supply
Power Supplies (PS)
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2320270 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 280 (C-4-2017) |
GTIN | 4046356560078 |
Weight per Piece (excluding packing) | 2,201.000 g |
Custom tariff number | 85371091 |
Country of origin | DE (Germany) |
Degree of protection | IP20 |
---|---|
Ambient temperature (operation) | -25 °C ... 70 °C (> 50 °C Derating: 2.5 %/K) |
Ambient temperature (start-up type tested) | -40 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Max. permissible relative humidity (operation) | ≤ 95 % (25 °C, non-condensing) |
Climatic class | 3K3 (in acc. with EN 60721) |
Nominal input voltage | 240 V AC |
---|---|
100 V AC | |
120 V AC -20 % / +15 % | |
230 V AC -20 % / +15 % | |
100 V AC ... 240 V AC | |
Input voltage range | 184 V AC ... 264 V AC |
96 V AC ... 138 V AC | |
96 V AC ... 264 V AC | |
AC frequency range | 45 Hz ... 65 Hz |
Buffer period | 1 h (38 AH) |
Permissible backup fuse | B16 230 V AC |
Power factor (cos phi) | 0.8 |
Nominal output voltage | 120 V AC |
---|---|
230 V AC | |
Nominal output current (IN) | 4.3 A (120 V AC, -25°C ... 50°C) |
2.2 A (230 V AC, -25°C ... 40°C) | |
POWER BOOST (IBoost) | 5.2 A (120 V AC, -25°C ... 40°C) |
2.7 A (230 V AC, -25°C ... 40°C) | |
Derating | > 50 °C ... 70 °C (2.5%/K) |
Connection in parallel | no |
Connection in series | No |
IQ technology | Yes |
---|---|
Net weight | 2.2 kg |
Efficiency | > 98 % (Mains operation) |
> 98 % | |
> 86 % | |
Protection class | I |
Degree of protection | IP20 |
MTBF (IEC 61709, SN 29500) | |
> (40 °C) | |
Mounting position | horizontal DIN rail NS 35, EN 60715 |
Assembly instructions | alignable: PN≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically alignable: PN<50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom |
Connection method | Screw connection |
---|---|
Conductor cross section solid min. | 1.5 mm² |
Conductor cross section solid max. | 6 mm² |
Conductor cross section flexible min. | 1.5 mm² |
Conductor cross section flexible max. | 4 mm² |
Conductor cross section AWG min. | 18 |
Conductor cross section AWG max. | 10 |
Stripping length | 8 mm |
Screw thread | M4 |
Connection method | Screw connection |
---|---|
Conductor cross section solid min. | 1.5 mm² |
Conductor cross section solid max. | 6 mm² |
Conductor cross section flexible min. | 1.5 mm² |
Conductor cross section flexible max. | 4 mm² |
Conductor cross section AWG min. | 18 |
Conductor cross section AWG max. | 10 |
Stripping length | 8 mm |
Screw thread | M4 |
Connection method | Screw connection |
---|---|
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 10 |
Stripping length | 8 mm |
Screw thread | M4 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
---|---|
Connection in acc. with standard | CUL |
Standards/regulations | EN 62040-2 |
Contact discharge | 4 kV (Test Level 2) |
Standards/regulations | EN 61000-4-3 |
Frequency range | 80 MHz ... 1 GHz |
Test field strength | 10 V/m |
Frequency range | 1.4 GHz ... 2 GHz |
Test field strength | 3 V/m |
Standards/regulations | EN 61000-4-4 |
Comments | Criterion B |
Standards/regulations | EN 62040-2 (Class C1) |
EN 61000-4-6 | |
Frequency range | 0.15 MHz ... 80 MHz |
Voltage | 10 V (Test Level 3) |
Standard – Limitation of mains harmonic currents | EN 61000-3-2 (Class A) |
UL approvals | UL/C-UL Recognized UL 1778 |
Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
Vibration (operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
15 Hz ... 150 Hz, 2.3g tv= 90 min. | |
Rail applications | EN 50121-4 |
China RoHS | Environmentally Friendly Use Period = 50 |
---|---|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX PROTECTION EN.pdf | 27 Mbytes | |
PHOENIX CONTACT-2320270-QUINT-UPS/ 1AC/ 1AC/500VA | 126 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.