ELR W3- 24DC/500AC- 2I 2297031 PHOENIX CONTACT "4 in 1" three-phase semiconductor reversing contactor with 2.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

ELR W3- 24DC/500AC- 2I 2297031 PHOENIX CONTACT "4 in 1" three-phase semiconductor reversing contactor with 2..

ELR W3- 24DC/500AC- 2I

2297031

PHOENIX_CONTACT

Available

Ship on today

"4 in 1" three-phase semiconductor reversing contactor with 24 V DC input, 2 A output current, emergency stop function, and adjustable overload shutdown.

More details


Programmable Logic Controllers Plcs

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$155.28
2+$151.15
3+$149.11
4+$147.80
6+$146.62
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Input data

Input nameDevice supply
Rated control circuit supply voltage US24 V DC
Voltage range with reference to US0.8 ... 1.25
Rated control supply current IS40 mA
Rated actuating voltage UC24 V DC
Voltage range with reference to UC0.8 ... 1.25
Rated actuating current IC5 mA
Protective circuitProtection against polarity reversal Parallel polarity protection diode
Surge protection
Typical response time< 35 ms
Typical turn-off time< 40 ms
Operating voltage displayGreen LED
Status displayYellow LED
IndicationRed LED
Input nameControl input right/left
Switching threshold9.6 V (“0” signal)
19.2 V (“1” signal)

Output data load output

Nominal output voltage500 V AC
Nominal output voltage range42 V AC ... 550 V AC
Load current range180 mA ... 2.4 A (see to derating)
Rated operating current at AC-512.4 A
Rated operating current at AC-53a2.4 A
Leakage current0 mA
Residual voltage< 0.3 V
Surge current100 A (t = 10 ms)
Protective circuitSurge protection

Output data reply output

NoteConfirmation 01: Floating PDT contact

Measuring technology and signaling contact

Measuring viaCurrent transformer for line current on L1 and L3

Connection data, control circuit

Connection nameControl circuits
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14

General

Test voltage input/output4 kVrms
Mounting positionVertical (horizontal DIN rail)
Assembly instructionsCan be aligned with spacing = 20 mm
Operating mode100% operating factor
DesignationStandards/regulations
Standards/regulationsDIN EN 50178
EN 60947
DesignationPower station requirements
Standards/regulationsDWR 1300 / ZXX01/DD/7080.8d
DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 50178
Insulationsafe isolation
Pollution degree2
Overvoltage categoryIII
Reversing frequency≤ 2 Hz

Dimensions

Width22.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Degree of protectionIP20

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2297031-ELR W3- 24DC/500AC- 2IEnglish146 KbytesPHOENIX CONTACT-2297031-ELR W3- 24DC/500AC- 2I

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or