MINI MCR-2-TC-UI 2902055 PHOENIX CONTACT Configurable temperature transducer with plug-in connection technol.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MINI MCR-2-TC-UI 2902055 PHOENIX CONTACT Configurable temperature transducer with plug-in connection technol..

MINI MCR-2-TC-UI

2902055

PHOENIX_CONTACT

Available

Ship on today

Configurable temperature transducer with plug-in connection technology for connecting thermocouples. Configurable via DIP switch or software. Screw connection technology, standard configuration

More details


* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$181.38
2+$176.76
3+$174.47
4+$173.00
5+$172.42
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Product description

Configurable, 3-way isolated temperature transducer with plug-in connection technology. The device is suitable for the connection of thermocouples. The measured values are converted into a linear and freely adjustable current or voltage signal. You can configure the device using one of the free software solutions. Default settings can also be made directly on the device by simply using the DIP switches (see configuration table). The measuring transducer supports fault monitoring and NFC communication.

Dimensions

Width6.2 mm
Height110.5 mm
Depth120.5 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Degree of protectionIP20

Input data

Configurable/programmableYes
Sensor types that can be used (TC)B, E, J, K, N, R, S, T, L, U, A-1, A-2, A-3, M, L
Temperature measuring range-250 °C ... 2500 °C (Range depends on sensor type, range can be set freely via software or in increments from -150°C to 1350°C via DIP switches)

Output data

Number of outputs1
Configurable/programmableYes
Voltage output signal0 V ... 5 V (via DIP switch)
1 V ... 5 V (via DIP switch)
0 V ... 10 V (via DIP switch)
10 V ... 0 V (via DIP switch)
0 V ... 10.5 V (Can be set via software)
Current output signal0 mA ... 20 mA (via DIP switch)
4 mA ... 20 mA (via DIP switch)
20 mA ... 0 mA (via DIP switch)
20 mA ... 4 mA (via DIP switch)
0 mA ... 21 mA (Can be set via software)
Max. output voltageapprox. 12.3 V
Max. output current24.6 mA
Short-circuit current< 31.5 mA
Load/output load voltage output≥ 10 kΩ
Load/output load current output≤ 600 Ω (at 20 mA)

Power supply

Supply voltage range9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
Typical current consumption32.7 mA (24 V DC)
66.8 mA (12 V DC)
Power consumption≤ 850 mW (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)

Connection data

Connection methodScrew connection
Single conductor/terminal point, solid, with ferrule, min.0.2 mm²
Single conductor/terminal point, solid, with ferrule, max.1.5 mm²
Single conductor/terminal point, solid, without ferrule, min.0.2 mm²
Single conductor/terminal point, solid, without ferrule, max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Min. AWG conductor cross section, flexible24
Max. AWG conductor cross section, flexible12
Stripping length10 mm
Screw threadM3

General

Maximum temperature coefficient≤ 0.01 %/K
Typical cold point errors2 K (2 K + (0,2 K * ΔT))
Protective circuitTransient protection
Electrical isolationReinforced insulation in accordance with IEC 61010-1
Overvoltage categoryII
Pollution degree2
Rated insulation voltage300 V (effective)
Test voltage, input/output/supply3 kV (50 Hz, 1 min.)
Electromagnetic compatibilityConformance with EMC Directive 2004/108/EC
Noise emissionEN 61000-6-4
Noise immunityEN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Housing materialPBT
Mounting positionany
Assembly instructionsThe T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
ConformanceCE-compliant
ATEXEx II 3 G Ex nA IIC T4 Gc X
UL, USA / CanadaUL 508 Listed
Class I, Div. 2, Groups A, B, C, D T6
Class I, Zone 2, Group IIC T6
Certificate of classificationDNV GL 14445-15HH

EMC data

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value0.06 %
DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value0.1 %
DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value0.05 %

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2902055-MINI MCR-2-TC-UIEnglish135 KbytesPHOENIX CONTACT-2902055-MINI MCR-2-TC-UI

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or