AXL F DI16/1 1H 2688310 PHOENIX CONTACT Axioline digital input module, 16 inputs, 24 V DC, single-wire conne.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

AXL F DI16/1 1H 2688310 PHOENIX CONTACT Axioline digital input module, 16 inputs, 24 V DC, single-wire conne..

AXL F DI16/1 1H

2688310

PHOENIX_CONTACT

Available

Ship on today

Axioline digital input module, 16 inputs, 24 V DC, single-wire connection method (including bus base module and plugs)

More details


AUTOMATION Industrial Automation - PHOENIX CONTACT

I/O systems - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width35 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth is valid when a TH 35-7.5 DIN rail is used (according to EN 60715).

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

Connection data

DesignationAxioline F connector
Connection methodPush-in connection
Note on connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

General

Mounting typeDIN rail
Net weight190.1 g
Note on weight specificationswith connectors and bus base module
Diagnostics messagesI/O supply failure Yes

Interfaces

Fieldbus systemLokalbus
DesignationAxioline F local bus
Connection methodBus base module
Transmission speed100 MBit/s

Axioline potentials

Communications power UBus5 V DC (via bus base module)
Current consumption from UBusmax. 120 mA
Supply of digital input modules UI24 V DC
Current consumption from UI20 mA

Digital inputs

Input nameDigital inputs
Description of the inputEN 61131-2 types 1 and 3
Connection methodPush-in connection
1-wire
Number of inputs16
Protective circuitPolarity reversal protection of the inputs Parallel diode (30 V, 5 s)
Input filter time3000 µs (default)
Input voltage range "0" signal-3 V DC ... 5 V DC
Input voltage range "1" signal11 V DC ... 30 V DC
Nominal input current at UIN2.4 mA

Standards and Regulations

Conformity with EMC directivesNoise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V
Noise emission test according to EN 61000-6-3 Radio interference properties EN 55022 Class B
Test section5 V communications power (logic), 24 V supply (I/O) 500 V AC 50 Hz 1 min.
5 V supply (logic)/functional earth ground 500 V AC 50 Hz 1 min.
24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min.
Mechanical testsVibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g
Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Protection classIII, IEC 61140, EN 61140, VDE 0140-1

[email protected]

[email protected] 4.027240404
[email protected] 4.127240404
[email protected] 5.027242204
[email protected] 5.127242604
[email protected] 6.027242604
[email protected] 7.027242604
[email protected] 8.027242604
[email protected] 9.027242604

ETIM

ETIM 3.0EC001599
ETIM 4.0EC001599
ETIM 5.0EC001599

UNSPSC

UNSPSC 6.0143172015
UNSPSC 7.090143201404
UNSPSC 1139121311
UNSPSC 12.0139121311
UNSPSC 13.239121311

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2688310-AXL F DI16/1 1HEnglish164 KbytesPHOENIX CONTACT-2688310-AXL F DI16/1 1H

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or