GST00-160-40-60-AOU 224550 EATON ELECTRIC 224550 GST00-160-40-60-AOU View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

GST00-160-40-60-AOU 224550 EATON ELECTRIC 224550 GST00-160-40-60-AOU

GST00-160-40-60-AOU

224550

EATON-MOELLER

Fuse disconnector, 160A, 500V/160A, 690V/160A, size 00

More details


Industrial Fuse Bases

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Fuse disconnector, 160A, 500V/160A, 690V/160A, size 00
Fuse disconnectors, rated operational current 160A, max. fuse-link 500V/160A, max. fuse-link 690V/160A, size NH00
[

Delivery program

Product range
60 mm system
Subrange
NH fuse switch-disconnectors
Description
Without hand guard
Mounting without holes
Function
For surface mounting on busbars
Number of poles
3 pole
Connection
Box terminal 1.5…70 mm2
top or bottom
Interval between busbar centres
40
50
60 mm
Rated operational current [Ie]
160 A
Max. fuse
500 V
160 A
690 V
100 A
Frame size
NH00
For use with
20 x 5/10
25 x 5/10
30 x 5/10
For use with
Double T profile
,

Technical data

General
Standards
Type tested low-voltage switchgear and controlgear assemblies (TTA); IEC/EN 60439-1, VDE 0660 Part 500
Type tested low-voltage switchgear and controlgear assemblies that are accessible for operations by unskilled persons (distribution board); IEC/EN 60439-3, VDE 0660 part 504
Standards
IEC/EN 60947-3
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
-25 - +55 °C
Ambient temperature
-25 - +55
Altitude
Max. 2000 m
Interval between busbar centres
40
50
60 mm
Mounting position
Vertical or horizontal
Overvoltage category/pollution degree
III/3
Protection type
IP20 (Operating state)
IP10 (Front cover open)
Degree of protection, from the frontOperational state
IP20
Degree of protection, from the frontFront cover open
IP10
Direction of incoming supply
as required
Lifespan, mechanical [Operations]
1700
Weight
0.93 kg
Contacts
Rated operational voltage [Ue]
690 V AC
Rated operational voltage [Ue]
440 V DC
Rated operational current [Ie]
160 A
Rated frequency [f]
40 - 60 Hz
Rated conditional short-circuit current AC [Iq]
50 kAeff
Rated conditional short-circuit current, DC [Iq]
25 kArms
Utilization category AC­22BRated making capacity
300 A
Utilization category AC­22BRated breaking capacity
300 A
Utilization category DC­21BRated making capacity
150 A
Utilization category DC­21BRated breaking capacity
150 A
Lifespan, electrical [Operations]
300
Electrical
≧ 300 Operations
Lifespan, mechanical [Operations]
1700
Heat dissipation at IthAC, without NH-SE
2.7 W
Heat dissipation at IthDC, without NH-SE
1.8 W
Rated insulation voltage [Ui]
750 V AC
Rated impulse withstand voltage [Uimp]
8 kV
Rated insulation voltage [Ui]
750 V
Max. fuse
Frame size
NH00
Max. rated current, gL/gG
160 A
Max. admissible heat dissipation NH-SE [Pv]
12 W
Terminal capacity
Box terminalStranded
1.5 - 70 mm2
Box terminalCopper strip [Number of segments x width x thickness]
6 x 9 x 0.8 mm
Box terminalTightening torque
2.6 Nm
Box terminalCopper band [Number of segments x width x thickness ]
6 x 9 x 0.8 mm
Notes

Fuse-link

,

Design verification as per IEC/EN 61439

Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+55 °C
,

Technical data ETIM 6.0

Low-voltage industrial components (EG000017) / Fuse switch disconnector (EC001040)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Fuse switch disconnector ([email protected] [AKF058010])
Version as main switch
No
Version as safety switch
No
Max. rated operation voltage Ue AC
690 V
Rated permanent current Iu
160 A
Rated operation power at AC-23, 400 V
64 kW
Conditioned rated short-circuit current Iq
50 kA
Rated short-time withstand current lcw
50 kA
Suitable for fuses
NH00
Number of poles
3
With error protection
No
Type of electrical connection of main circuit
Screw connection
Suitable for ground mounting
No
Suitable for front mounting 4-hole
No
Suitable for busbar mounting
Yes
Type of control element
Rocker lever
Position control element
Front side
Motor drive optional
No
Motor drive integrated
No
Version as emergency stop installation
No
Degree of protection (IP), front side
IP20
,

Dimensions

Drilling dimensions
]

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.