SPX007A2-4A1B1 125260 EATON MOELLER Variable frequency drive SPX 3-/3-phase 480 V 5.5 kW dynamic vector co..

SPX007A2-4A1B1

125260

EATON - MOELLER

Available

Ship on today

Product on demand only, returns will not be accepted.

Variable frequency drive SPX 3-/3-phase 480 V 5.5 kW ; dynamic vector control; protection type IP54; integrated EMC filter and braking transistor

More details


Variable Adjustable Frequency Speed Drives Inverters Vfd Vvvf Voltage

Frequency inverters - EATON - MOELLER

Frequency inverters SVX-SPX - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  Variable frequency drives
Part group reference (e.g. DIL)
  SPX
Rated operational voltage
Ue 400 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Output voltage with Ve
U2 400 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Mains voltage (50/60Hz)
ULNV380 (-15%) - 500 (+10%)
Rated operational current
   
At 150% overload
IeA12
At 110% overload
IeA16
Note
  Overload cycle for 60 s every 600 s
Assigned motor rating
   
Note
  For AC motors with internal and external ventilation with 50 Hz / 60 Hz
Note
  Overload cycle for 60 s every 600 s
Note
  at 400 V, 50 Hz
150 % Overload
PkW5.5
110 % Overload
PkW7.5
150 % Overload
IMA11.3
110 % Overload
IMA15.2
Note
  at 440 - 480 V, 60 Hz
150 % Overload
PHP7.5
110 % Overload
PHP10
150 % Overload
IMA11
110 % Overload
IMA14
Degree of Protection
  IP54
Fitted with
  Radio interference suppression filter
Brake chopper
Frame size
  FR5
Connection to SmartWire-DT
  No
Technical data
General
Standards
  EMC: EN 61800-3:2004+A1-2012
Safety: EN 61800-5-1: 2003
Certifications
  CE, cUL, c-Tick
Production quality
  RoHS, ISO 9001
Climatic proofing
ρw%< 95% relative humidity, no condensation, no corrosion, no dripping water
Ambient temperature
   
operation (150 % overload)
ϑ°C-10 - +40
Storage
ϑ°C-40 - +70
Radio interference level
   
Radio interference class (EMC)
  C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Environment (EMC)
  1st and 2nd environments
Mounting position
  Vertical
Altitude
 m0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 3000 m
Degree of Protection
  IP54
Protection against direct contact
  BGV A3 (VBG4, finger- and back-of-hand proof)
Main circuit
Supply
   
Rated operational voltage
Ue 400 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Mains voltage (50/60Hz)
ULNV380 (-15%) - 500 (+10%)
System configuration
  AC supply systems with earthed center point
Supply frequency
fLNHz50/60
Frequency range
fLNHz45 - 66
Power section
   
Function
  Frequency inverter with internal DC link and IGBT inverter
Output voltage with Ve
U2 400 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Output Frequency
f2Hz0 - 320
Switching frequency
fPWMkHz10
adjustable 1 - 16
Operation Mode
  U/f control
sensorless vector control (SLV)
optional: Vector control with feedback (CLV)
Frequency resolution (setpoint value)
ΔfHz0.01
Rated operational current
   
At 150% overload
IeA12
At 110% overload
IeA16
Fitted with
  Radio interference suppression filter
Brake chopper
Frame size
  FR5
Motor feeder
   
Note
  For AC motors with internal and external ventilation with 50 Hz / 60 Hz
Note
  Overload cycle for 60 s every 600 s
Note
  at 400 V, 50 Hz
150 % Overload
PkW5.5
110 % Overload
PkW7.5
Note
  at 440 - 480 V, 60 Hz
150 % Overload
PHP7.5
110 % Overload
PHP10
Control section
External control voltage
UcV24 V DC (max. 250 mA)
Reference voltage
UsV10 V DC (max. 10 mA)
Analog inputs
  2, parameterizable, 0 - 10 V DC, 0/4 - 20 mA
Analog outputs
  1, parameterizable, 0/4 - 20 mA
Digital inputs
  6, parameterizable, max. 30 V DC
Digital outputs
  1, parameterizable, 48 V DC/50 mA
Relay outputs
  2, parameterizable, N/O, 8 A (24 V DC) / 8 A (250 V AC) / 0,4 A (125 V DC)
Assigned switching and protective elements
Power Wiring
   
150 % overload (CT/IH, at 50 °C)
  DX-LN3-016
Motor feeder
   
150 % overload (CT/IH, at 50 °C)
  DX-LM3-016
110 % overload (VT/IL, at 40 °C)
  DX-LM3-016
150 % overload (CT/IH, at 50 °C)
  DX-SIN3-016
Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Rated operational current for specified heat dissipation
InA12
Equipment heat dissipation, current-dependent
PvidW138
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Meets the product standard's requirements.
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Approvals
Product Standards  UL 508C; CSA-C22.2 No. 14; IEC/EN61800-3; IEC/EN61800-5; CE marking
UL File No.  E134360
UL Category Control No.  NMMS, NMMS2, NMMS7. NMMS8
CSA File No.  UL report applies to both US and Canada
CSA Class No.  3211-06
North America Certification  UL listed, certified by UL for use in Canada
Specially designed for North America  No
Suitable for  Branch circuits
Max. Voltage Rating  3~ 480 V AC IEC: TN-S UL/CSA: Y (Solidly Grounded Wey)
Degree of Protection  IEC: IP54
Dimensions
>

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or