NZMH2-A100-SVE 113332 EATON MOELLER Circuit-breaker, 3p, 100A, plug-in module View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

NZMH2-A100-SVE 113332 EATON MOELLER Circuit-breaker, 3p, 100A, plug-in module

NZMH2-A100-SVE

113332

EATON - MOELLER

Available

Ship on today

Product on demand only, returns will not be accepted.

Circuit-breaker, 3p, 100A, plug-in module

More details


Circuit Breakers Electrical Power

Circuit-breakers NZM - EATON - MOELLER

NZM2 - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$491.65
2+$491.16
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  Circuit-breaker
Protective function
  System and cable protection
Standard/Approval
  IEC
Installation type
  Plug-in units
Release system
  Thermomagnetic release
Construction size
  NZM2
Number of poles
  3 pole
Standard equipment
  Screw connection
Switching capacity
   
400/415 V 50 Hz
IcukA150
Rated current = rated uninterrupted current
   
Rated current = rated uninterrupted current
In = IuA100
Setting range
   
Overload trip
   
IrA 80 - 100
Short-circuit releases
   
Non-delayed
Ii = In x … 6 - 10
Technical data
General
Standards
  IEC/EN 60947
Protection against direct contact
  Finger and back of hand proof to VDE 0106 Part 100
Climatic proofing
  Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
   
Ambient temperature, storage
 °C- 25 - + 70
Operation
 °C-25 - +70
Mechanical shock resistance (10 ms half-sinusoidal shock) according to IEC 60068-2-27
 g20 (half-sinusoidal shock 20 ms)
Safe isolation to EN 61140
   
Between auxiliary contacts and main contacts
 V AC500
between the auxiliary contacts
 V AC300
Min. ambient temperature, storage
 °C- 25
Weight
 kg2.345
Mounting position
  
Vertical and 90° in all directions
 With residual-current release XFI:
- NZM1, N1, NZM2, N2: vertical and 90° in all directions
with plug-in adapter elements
- NZM1, N1, NZM2, N2: vertical, 90° right/left
with withdrawable unit:
- NZM3, N3: vertical, 90 ° left
- NZM4, N4: vertical
with remote operator:
- NZM2, N(S)2, NZM3, N(S)3, NZM4, N(S)4: vertical and 90° in all directions

Direction of incoming supply
  as required
Degree of protection
   
Device
  In the operating controls area: IP20 (basic degree of protection)
Enclosures
  With insulating surround: IP40
With door coupling rotary handle: IP66
Terminations
  Tunnel terminal: IP10
Phase isolator and strip terminal: IP00
Other technical data (sheet catalogue)
  

Circuit-breakers
Rated current = rated uninterrupted current
In = IuA100
Rated surge voltage invariability
Uimp  
Main contacts
 V8000
Auxiliary contacts
 V6000
Rated operational voltage
UeV AC690
 
  

1) Details apply for 3 pole system protection circuit-breaker with thermomagnetic release NZMN(H)1(2)(3)-A... to 500 A.

For rated operating voltage switching via 3 contacts:

DC correction factor for instantaneous release response value: NZM1: 1.25, NZM2: 1.35, NZM3: 1.45

Set value for Ii at DC = set value Ii AC/correction factor DC

Switching of one pole via two series contacts Switching of one pole via three series contacts
   
Overvoltage category/pollution degree
  III/3
Rated insulation voltage
UiV1000
Use in unearthed supply systems
 V 690
Switching capacity
Rated short-circuit making capacity
Icm  
240 V
IcmkA330
400/415 V
IcmkA330
440 V 50/60 Hz
IcmkA286
525 V 50/60 Hz
IcmkA105
690 V 50/60 H
IckA40
Rated short-circuit breaking capacity Icn
Icn  
Icu to IEC/EN 60947 test cycle O-t-CO
IcukA 
240 V 50/60 Hz
IcukA150
400/415 V 50/60 Hz
IcukA150
440 V 50/60 Hz
IcukA130
525 V 50/60 Hz
IcukA50
690 V 50/60 Hz
IcukA20
750 V DC
IcukA999999
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO
IcskA 
240 V 50/60 Hz
IcskA150
400/415 V 50/60 Hz
IcskA150
440 V 50/60 Hz
IcskA130
525 V 50/60 Hz
IcskA37.5
690 V 50/60 Hz
IcskA5
 
  Maximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit-breaker.
Rated short-time withstand current
   
t = 0.3 s
IcwkA1.9
t = 1 s
IcwkA1.9
Utilization category to IEC/EN 60947-2
  A
Rated making and breaking capacity
   
Rated operational current
IeA 
AC-1
   
380 V 400 V
IeA100
415 V
IeA100
690 V
IeA100
AC--3
   
380 V 400 V
IeA100
415 V
IeA100
660 V 690 V
IeA100
Lifespan, mechanical(of which max. 50 % trip by shunt/undervoltage release)
Operations 20000
Lifespan, electrical
   
AC-1
   
400 V 50/60 Hz
Operations 10000
415 V 50/60 Hz
Operations 10000
690 V 50/60 Hz
Operations 7500
AC--3
   
400 V 50/60 Hz
Operations 6500
415 V 50/60 Hz
Operations 6500
690 V 50/60 Hz
Operations 5000
Max. operating frequency
 Ops/h120
Total downtime in a short-circuit
 ms< 10
Terminal capacity
Standard equipment
  Screw connection
Round copper conductor
   
Box terminal
   
Solid
 mm21 x (10 - 16)
2 x (6-16)
Stranded
 mm21 x (25 - 185)
2 x (25 - 70)
Tunnel terminal
   
Solid
 mm21 x 16
Stranded
 mm2 
Stranded
 mm21 x (25 - 185)
Bolt terminal and rear-side connection
   
Direct on the switch
   
Solid
 mm21 x (10 - 16)
2 x (6 - 16)
Stranded
 mm21 x (25 - 185)
2 x (25 - 70)
Al conductors, Cu cable
   
 
   
Solid
 mm21 x 16
Bolt terminal and rear-side connection
   
Flat copper strip, with holes
min.mm2 x 16 x 0.8
Flat copper strip, with holes
max.mm10 x 24 x 0.8
Cu strip (number of segments x width x segment thickness)
   
Box terminal
   
 
min.mm2 x 9 x 0.8
 
max.mm10 x 16 x 0.8
(2x) 8 x 15.5 x 0,8
Bolt terminal and rear-side connection
   
Flat copper strip, with holes
min.mm2 x 16 x 0.8
Flat copper strip, with holes
max.mm10 x 24 x 0.8
Copper busbar (width x thickness)
mm  
Bolt terminal and rear-side connection
   
Screw connection
  M8
Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Rated operational current for specified heat dissipation
InA100
Equipment heat dissipation, current-dependent
PvidW25.65
Operating ambient temperature min.
 °C-25
Operating ambient temperature max.
 °C70
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Meets the product standard's requirements.
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 6.0
Low-voltage industrial components (EG000017) / Power circuit-breaker for trafo/generator/installation prot. (EC000228)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Circuit breaker for power transformer, generator and system protection ([email protected] [AJZ716010])
Rated permanent current Iu
 A100
Rated voltage
 V690 - 690
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
 kA150
Overload release current setting
 A80 - 100
Adjustment range short-term delayed short-circuit release
 A0 - 0
Adjustment range undelayed short-circuit release
 A600 - 1000
Integrated earth fault protection
  No
Type of electrical connection of main circuit
  Screw connection
Device construction
  Built-in device plug-in technique
Suitable for DIN rail (top hat rail) mounting
  No
DIN rail (top hat rail) mounting optional
  Yes
Number of auxiliary contacts as normally closed contact
  0
Number of auxiliary contacts as normally open contact
  0
Number of auxiliary contacts as change-over contact
  0
Switched-off indicator available
  No
With under voltage release
  No
Number of poles
  3
Position of connection for main current circuit
  Front side
Type of control element
  Rocker lever
Complete device with protection unit
  Yes
Motor drive integrated
  No
Motor drive optional
  Yes
Degree of protection (IP)
  IP20
Characteristics

Datasheet - PDF

Title:Language:Size:Type:
Datasheet 1: 113332 - NZMH2-A100-SVEEnglish219 KbytesDatasheet 1: 113332 - NZMH2-A100-SVE
Complete catalogue 1: 113332 - NZMH2-A100-SVEEnglish40 MbytesDatasheet 1: 113332 - NZMH2-A100-SVE

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or