XN-1CNT-24VDC 140069 4520644 EATON ELECTRIC Analog input card XI/ON, 24 V DC, 1AI (meter, 32Bit) View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

XN-1CNT-24VDC 140069 4520644 EATON ELECTRIC Analog input card XI/ON, 24 V DC, 1AI (meter, 32Bit)

XN-1CNT-24VDC

140069

4520644

EATON-MOELLER

Analog input card XI/ON, 24 V DC, 1AI (meter, 32Bit)

XION Module; 1 Quick counter entry

More details


Remote I / O Modules XION

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Go to successor article:

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



EL-Nummer (Norway)
4520644
Analog input card XI/ON, 24 V DC, 1AI (meter, 32Bit)
The XI/ON standard I/O system offers the right I/O solution for every application due to its great modularity and large variety of functions. Pluggable modules, hot-swapping of modules, wiring on the basic module screw or tension spring, modules' mechanical coding. The standard gateways support the CANopen bus systems, PROFIBUS-DP deviceNet and Ethernet.

Delivery program

Function
XI/ON technology modules
Function
XN Slice module
Short Description
1 Digital input/24 V DC
1 Digital outputs/24 V DC
Counting modes: infinite, once only or periodic count
Frequency, rotational speed or period count
Acquisition of signals from rotary encoders (track A/B)
For use with
XN-S4T-SBBS
XN-S4S-SBBS

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
0 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
0 °C
Operating ambient temperature max.
+55 °C
Degree of Protection
IP20
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

PLC's (EG000024) / Fieldbus, decentr. periphery - function-/technology module (EC001601)
Electric engineering, automation, process control engineering / Control / Field bus, decentralized peripheral / Field bus, decentralized peripheral - function-/technology module ([email protected] [BAA066014])
Supply voltage AC 50 Hz
0 - 0 V
Supply voltage AC 60 Hz
0 - 0 V
Supply voltage DC
11 - 30 V
Voltage type of supply voltage
DC
Number of functions
0
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of HW-interfaces Wireless
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
1
With optical interface
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
Yes
Supporting protocol for CAN
Yes
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for MODBUS
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Radio standard Bluetooth
No
Radio standard WLAN 802.11
No
Radio standard GPRS
No
Radio standard GSM
No
Radio standard UMTS
No
IO link master
No
System accessory
Yes
Suitable for counting
Yes
Suitable for weighting
No
Suitable for temperature control
No
Suitable for welding control
No
Suitable for pressure control
No
Suitable for NC
No
Function electronic positioning available
Yes
Suitable for CNC
No
Suitable for SSI
No
Suitable for incremental data detection
Yes
Suitable for detection absolute value
Yes
Flux controller possible
No
Suitable for flux measurement
No
Suitable for path controller
No
Suitable for cam controller
No
Suitable for flying saw
No
Suitable for multi-axis control
No
Single-axis controller possible
Yes
Suitable for multi-axis positioning
No
Single-axis positioning possible
Yes
Function block restart blockage
No
Function block automatic reset
No
Contactor control function block
No
Function block emergency stop
No
Function block contactless working protection installation
No
Function block affirm pushbutton
No
Function block 2-hand switching
No
Function block operating mode selection
Yes
Function block access control
No
Degree of protection (IP)
IP20
Degree of protection (NEMA)
Fieldbus connection over separate bus coupler possible
Yes
Frequency measurement
Yes
Rail mounting possible
No
Wall mounting/direct mounting
No
Front build in possible
No
Rack-assembly possible
No
Suitable for safety functions
No
Category according to EN 954-1
SIL according to IEC 61508
None
Performance level acc. EN ISO 13849-1
None
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Explosion safety category for gas
None
Explosion safety category for dust
None
Width
50.6 mm
Height
114.8 mm
Depth
74.4 mm

Approvals

Product Standards
UL 508; CSA-C22.2 No. 142; IEC/EN 6113-2; CE marking
UL File No.
E205091
UL Category Control No.
NRAQ, NRAQ7
CSA File No.
UL report applies to both US and Canada
CSA Class No.
2252-01, 2252-81
North America Certification
UL recognized, certified by UL for use in Canada
Specially designed for North America
No
Current Limiting Circuit-Breaker
No
Degree of Protection
IEC: IP20, UL/CSA Type: -

Dimensions

2725DIM-3
Link to sheet catalogue

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.