PA18CLR30TOM6 CARLO GAVAZZI Selected parameters SYSTEM Retro-reflective HOUSING M18 SENSING RANGE 1 ... 5 m .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PA18CLR30TOM6 CARLO GAVAZZI Selected parameters SYSTEM Retro-reflective HOUSING M18 SENSING RANGE 1 ... 5 m ..

PA18CLR30TOM6

PA18CLR30TOM6

CARLO GAVAZZI

Available

Ship on today

Selected parameters SYSTEM Retro-reflective HOUSING M18 SENSING RANGE 1 ... 5 m CONNECTION M12 Plug AC OUTPUT AC SCR MATERIAL Plastic Others SENSING RANGE 3 m HOUSING M18 x 83,5 mm MATERIAL PBTP

More details


Photocells Photoelectric Sensors Detectors

Sensors

Photoelectric Sensors

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+$60.98
4+$57.26
7+$56.15
10+$55.53
14+$55.07
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Photoelectrics
Retro-reflective
Type PA18CLR30T, AC, PBTP housing
• Range: 3 m
• Modulated infrared light
• Supply voltage: 20 to 250 VAC
• Output: 500 mA SCR
• Make and break switching functions
• LED output indication
• High immunity to ambient light
• Cable and plug versions
Product Description
Ordering Key
PA18CLR30TOM6
The PA18CLR.. is a family of inexpensive general purpose Retro-reflective sensors in industrial standard 18 mm cylindrical PBTP housing. They are useful for simple applications where a basic
sensor provides adequate sensing performance. The sensors are simple to use and no adjustment are nec- essary. The output is a 2- wire NO or NC thyristor (SCR) output.
Type
Housing style Housing size Housing material Housing length Detection principle Sensing distance Output type
Output configuration
Connection type
Type Selection
Housing Rated Ordering no. Ordering no. Ordering no. Ordering no. diameter operating SCR/Cable SCR/Plug SCR/Cable SCR/Plug
dist. (Sn) Make switching Make switching Break switching Break switching
M18 3 m PA18CLR30TO PA18CLR30TOM6 PA18CLR30TC PA18CLR30TCM6
Note: Plugs and reflectors to be ordered separately
Specifications
Rated operating dist. (Sn) Up to 3 m
Ref. reflector type ER4,
Æ 84 mm
Temperature drift 0.4%/K
Hysteresis (H)
(Differential travel) 3 to 20%
Rated operational volt. (UB) 20 to 250 VAC,
45 to 65 Hz
Output current (AC 12, AC 140)
Continuous (Ie) £ 500 mA
Short-time (I) £ 3 A, max. 20 ms
Min. operational current (Im) 10 mA
OFF-state current (Ir) < 5 mA, typ. 2.6 mA Voltage drop (Ud) £ 10 VAC, typ. 7 VAC Protection Transients
Transient voltage 1 kV/0.5 J
Light source GaAlAs LED, 880 nm Light type Infrared, modulated Optical angle ± 2.2°
Light spot size 150 mm at 2 m
Ambient light Max. 10,000 lux
Operating frequency (f) Max. 20 Hz, light/dark ratio 1:2
Response time
OFF-ON (tON) £ 20 ms
ON-OFF (tOFF) £ 30 ms
Power ON delay (tv) Typ. 100 ms
Indication function Dark (NC) or light (NO) switching
Output ON LED, yellow
Environment
Overvoltage category III (IEC 60664/60664A 60947-1) Pollution degree 3 (IEC 60664/60664A 60947-1) Degree of protection IP 67 (IEC 60529 60947-1)
Temperature
Operating -20° to +60°C (-4° to 140°F) Storage -30° to + 70°C (-22° to 158°F)
Vibration 10 to 150 Hz, 0.5 mm/-
7.5 g (IEC 60068-2-6)
Shock 2 x 1 m 100 x 0.5 m
(IEC 60068-2-32)
Dielectric voltage 1600 V (IEC 60364-4-41)
Specifications are subject to change without notice (05.05.2008) 1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters SYSTEM Retro-reflective HOUSING M18 SENSING RANGE 1 ... 5 m CO - CARLO GAVAZZEnglish142 Kbytespdf1-mostradoSelected parameters SYSTEM Retro-reflective HOUSING M18 SENSING RANGE 1 ... 5 m CO - CARLO GAVAZZ
pdf1-Selected parameters SYSTEM Retro-reflective HOUSING M18 SENSING RANGE 1 ... 5 m CO - CARLO GAVAEnglish12 Mbytespdf1-mostradoSelected parameters SYSTEM Retro-reflective HOUSING M18 SENSING RANGE 1 ... 5 m CO - CARLO GAVAZZ
pdf2-mostradoSelected parameters SYSTEM Retro-reflective HOUSING M18 SENSING RANGE 1 ... 5 m CO - CARLO GAVAZZEnglish402 Kbytespdf1-mostradoSelected parameters SYSTEM Retro-reflective HOUSING M18 SENSING RANGE 1 ... 5 m CO - CARLO GAVAZZ

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or