PHOENIX CONTACT  STEP-PS/ 1AC/24DC/1.75 2868648 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

STEP-PS/ 1AC/24DC/1.75 2868648 PHOENIX CONTACT Power supply unit

Reference: STEP-PS/ 1AC/24DC/1.75

Code: 2868648

Manufacturer: PHOENIX CONTACT

Description:

Power supply unit
STEP POWER Primary Switch-On Power Supply for Rail Mounting, Input: Single Phase, Output: 24 V DC/1.75 A
Primary-switched STEP POWER power supply for DIN rail mounting, input: 1-phase, output: 24 V DC/1.75 A

Categories:

  • Low-voltage industrial components > DC-power supply
  • PHOENIX CONTACT > Power Supplies (PS)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

Unit Price: 99,87 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 2-3 weeks.

  • These delivery times are an estimate any may vary when the item order has been processed.

LAST VIEWED

MORE INFO

Technical data

Input data
AC operation
Nominal input voltage range100 V AC ... 240 V AC
Input voltage range85 V AC ... 264 V AC
95 V DC ... 250 V DC
Input voltage range AC85 V AC ... 264 V AC
Input voltage range DC95 V DC ... 250 V DC
Voltage type of supply voltageAC/DC
Inrush current< 15 A (typical)
Inrush current integral (I2t)< 0.6 A2s
AC frequency range45 Hz ... 65 Hz
Frequency range DC0 Hz
Mains buffering timetyp. 25 ms (120 V AC)
typ. 150 ms (230 V AC)
Current consumption0.6 A (120 V AC)
0.3 A (230 V AC)
Nominal power consumption84.2 VA
Protective circuitTransient surge protection; Varistor
Power factor (cos phi)0.57
Typical response time< 0.5 s
Input fuse3.15 A (slow-blow, internal)
Recommended breaker for input protection6 A ... 16 A (Characteristics B, C, D, K)

Output data
Efficiency> 89 % (for 230 V AC and nominal values)
Output characteristicU/I
Nominal output voltage24 V DC
Setting range of the output voltage (USet)22.5 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted)
Output current Imax3.75 A
Nominal output current (IN)1.75 A (-25 °C ... 55 °C)
1.9 A (-25 °C ... 40 °C permanent)
Derating55 °C ... 70 °C (2.5 %/K)
Feedback voltage resistance≤ 35 V DC
Protection against overvoltage at the output (OVP)< 35 V DC
Control deviation< 1 % (change in load, static 10 % ... 90 %)
< 2 % (change in load, dynamic 10 % ... 90 %)
< 0.1 % (change in input voltage ±10 %)
Residual ripple< 60 mVPP(20 MHz)
Short-circuit-proofyes
Output power42 W
Peak switching voltages nominal load< 40 mVPP(20 MHz)
Maximum no-load power dissipation< 0.7 W
Power loss nominal load max.5 W
Rise time< 0.5 s (UOUT(10 % ... 90 %))
Connection in parallelyes, for redundancy and increased capacity
Connection in seriesyes

Connection data
Input
Connection methodScrew connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length6.5 mm
Screw threadM3
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm
Output
Connection methodScrew connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length6.5 mm
Screw threadM3
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

Signaling
Types of signalingLED
Operating voltage displayGreen LED
Signal output: LED status indicator
Status display"DC OK" LED green
Note on status displayUOUT> 21.5 V: LED lights up

Electrical properties
Number of phases1.00
Insulation voltage input/output4 kV AC (type test)
3.75 kV AC (routine test)
Insulation voltage output / PE500 V DC (routine test)
Insulation voltage input/output3.75 kV AC (routine test)
4 kV AC (type test)
Insulation voltage input / PE3.5 kV AC (type test)
2 kV AC (routine test)

Product properties
Product typePower supply
Product familySTEP POWER
MTBF (IEC 61709, SN 29500)> 1569000 h (40 °C)
Data management status
Article revision05
Insulation characteristics
Protection classII (in closed control cabinet)
Overvoltage categoryIII
Degree of pollution2

Dimensions
Dimensional drawingjjlzokwxrz.jpg
Width54 mm
Height90 mm
Depth Device depth (DIN rail mounting)55 mm (Device depth (DIN rail mounting))
Horizontal pitch3 Div.
Installation dimensions
Installation distance right/left0 mm / 0 mm
Installation distance top/bottom30 mm / 30 mm

Mounting
Mounting typeDIN rail mounting
Assembly notealignable: 0 mm horizontally, 30 mm vertically
Mounting positionhorizontal DIN rail NS 35, EN 60715
With protective coatingno

Material specifications
Housing materialPlastic
Housing materialPolycarbonate
Foot latch materialPOM (Polyoxymethylene)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 55° C derating : 2.5%/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Climatic class3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.
Temp codeT4A (70 °C)

Standards and regulations
Rail applicationsEN 50121-4
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Standard - Electrical safetyIEC 62368-1 (SELV)
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipmentEN 50178
Standard – Safety extra-low voltageIEC 62368-1 (SELV) und EN 60204-1 (PELV)
Standard - Safe isolationDIN VDE 0100-410
Standard - Safety of transformersEN 61558-2-16

Approvals
CSACSA-C22.2 No. 107.1-01
Shipbuilding approvalDNV GL (EMC B) ABS, NK
UL approvalsUL/C-UL listed UL 508
UL/C-UL Recognized UL 60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4A (Hazardous Location)
NEC Class 2 as per UL 1310
Conformity/Approvals
SIL in accordance with IEC 615080

EMC data
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emissionEN 61000-6-3
EN 61000-6-4
EMC requirements for noise immunityEN 61000-6-1
EN 61000-6-2
Electrostatic discharge
Standards/regulationsEN 61000-4-2
Electrostatic discharge
Contact discharge6 kV (Test Level 3)
Discharge in air8 kV (Test Level 3)
CommentsCriterion A
Electromagnetic HF field
Standards/regulationsEN 61000-4-3
Electromagnetic HF field
Frequency range80 MHz ... 1 GHz
Test field strength10 V/m
Frequency range1 GHz ... 2 GHz
Test field strength10 V/m
Frequency range2 GHz ... 3 GHz
Test field strength10 V/m
CommentsCriterion A
Fast transients (burst)
Standards/regulationsEN 61000-4-4
Fast transients (burst)
Input4 kV (Test Level 4 - asymmetrical)
Output2 kV (Test Level 3 - asymmetrical)
CommentsCriterion A
Surge voltage load (surge)
Standards/regulationsEN 61000-4-5
Surge voltage load (surge)
Input1 kV (Test Level 2 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Output0.5 kV (Test Level 1 - symmetrical)
0.5 kV (Test Level 1 - asymmetrical)
CommentsCriterion B
Conducted interference
Standards/regulationsEN 61000-4-6
Conducted interference
Frequency range10 kHz ... 15 kHz
10 kHz ... 15 kHz
CommentsCriterion A
Criterion A
Voltage3 V (Test Level 2)
3 V (Test Level 2)
Conducted interference
Frequency range10 kHz ... 15 kHz
10 kHz ... 15 kHz
CommentsCriterion A
Criterion A
Voltage3 V (Test Level 2)
3 V (Test Level 2)
Voltage dips
Standards/regulationsEN 61000-4-11
Emitted interference
Standards/regulationsEN 61000-6-3
Radio interference voltage in acc. with EN 55011EN 55011 (EN 55022) class B used in industry and residential area / EMC 1
Emitted radio interference in acc. with EN 55011EN 55011 (EN 55022) class B used in industry and residential area / EMC 1

ETIM for 2868648 Low-voltage industrial controls and switchgear (EC002540)

Feature nameVoltage type (supply voltage) (EF002991)
Feature valueAC/DC
Feature name1st secondary output voltage (EF006792)
Feature value22.5 V
Feature nameMax. output current 1 (EF008284)
Feature value1.75 A
Feature nameSecondary voltage adjustable (EF007002)
Feature valueYes
Feature nameNominal value output voltage 1 (EF009393)
Feature value24 V
Feature nameNominal value output current 1 (EF009396)
Feature value1.75 A
Feature nameShort-circuit-proof (EF007332)
Feature valueYes
Feature nameRated supply voltage AC 50 Hz (EF007076)
Feature value85 V
Feature nameRated supply voltage AC 60 Hz (EF007077)
Feature value100 V
Feature nameRated supply voltage DC (EF007078)
Feature value95 V
Feature nameOutput voltage stabilized (EF003092)
Feature valueYes
Feature namePower consumption (EF000346)
Feature value84.2 VA
Feature namePower output (EF003034)
Feature value42 W
Feature nameStabilized (EF005302)
Feature valueYes
Feature nameType of electric connection (EF003961)
Feature valueScrew connection
Feature nameSuitable for rail mounting (EF003972)
Feature valueYes
Feature nameWall mounting possible (EF003973)
Feature valueYes
Feature nameModular version (EF001126)
Feature valueYes
Feature nameWidth in number of modular spacings (EF002950)
Feature value3
Feature nameBuilt-in height (EF000332)
Feature value90 mm
Feature nameDirect mounting possible (EF005689)
Feature valueYes
Feature nameWidth (EF000008)
Feature value54 mm
Feature nameHeight (EF000040)
Feature value90 mm
Feature nameDepth (EF000049)
Feature value61 mm
Feature nameSuitable for safety functions (EF001597)
Feature valueYes
Feature nameSIL according to IEC 61508 (EF009889)
Feature valueNone
Feature namePerformance level according to EN ISO 13849-1 (EF007399)
Feature valueNone
Feature nameDegree of protection (IP) (EF005474)
Feature valueIP20
Feature nameDegree of protection (NEMA) (EF011959)
Feature valueOther

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.