PHOENIX CONTACT  TRIO-DIODE/12-24DC/2X10/1X20 2866514 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

TRIO-DIODE/12-24DC/2X10/1X20 2866514 PHOENIX CONTACT Redundancy module

Reference: TRIO-DIODE/12-24DC/2X10/1X20

Code: 2866514

Manufacturer: PHOENIX CONTACT

Description:

Redundancy module
Redundancy module with functional monitoring, 12 ... 24 V DC, 2x 10 A, 1x 20 A
Redundancy module with function monitoring, 12 ... 24 V DC, 2x 10 A, 1x 20 A

Categories:

  • Low-voltage industrial components > Surge protection module
  • PHOENIX CONTACT > Power Supplies (PS)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

Unit Price: 84,43 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 2-3 weeks.

  • These delivery times are an estimate any may vary when the item order has been processed.

LAST VIEWED

MORE INFO

Technical data

Input data
DC operation
Nominal input voltage range12 V DC ... 24 V DC
Input voltage range10 V DC ... 30 V DC
Input voltage range DC10 V DC ... 30 V DC
Voltage type of supply voltageDC
Reverse polarity protection< yes60 V
Nominal input current (IN)2x 10 A (-25 °C ... 55 °C)
1x 20 A (-25 °C ... 55 °C)
Maximum current Imax2x 15 A (-25 °C ... 40 °C)
1x 30 A (-25 °C ... 40 °C)
Transient surge protectionVaristor
Voltage drop, input/output0.5 V

Output data
Efficiency> 97 %
Nominal output voltageUIn- 0,5 V
Nominal output current (IN)20 A (Increasing power)
10 A (Redundancy)
Derating55 °C ... 70 °C (2.5 %/K)
Power loss nominal load max.7 W (IOUT= 10 A)
Connection in seriesno
Signal: Floating redundancy OK
Output descriptionContact closed when UIN1& UIN2> 8 V
Maximum switching voltagemax. 60 V DC
Maximum inrush current≤ 100 mA (short-circuit-proof)

Connection data
Input
Connection methodScrew connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length9 mm
Screw threadM2,5
Tightening torque, min0.4 Nm
Tightening torque max0.5 Nm
Output
Connection methodScrew connection
Conductor cross section, rigid min.0.5 mm²
Conductor cross section, rigid max.6 mm²
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.4 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.10
Stripping length14 mm
Screw threadM3
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm
Signal
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Screw threadM2,5
Tightening torque, min0.4 Nm
Tightening torque max0.5 Nm

Signaling
Types of signalingLED
Relay contact
Signal output: Floating redundancy OK
Status displayLED redundancy OK
Note on status displayUIN1& UIN2> 8 V: LED lights up green

Electrical properties
Insulation voltage input, output / housing500 V

Product properties
Product typeRedundancy module
Product familyTRIO DIODE
MTBF (IEC 61709, SN 29500)> 10000000 h (40 °C)
LEDyes
Data management status
Article revision03
Insulation characteristics
Protection classIII
Degree of pollution2

Dimensions
Width32 mm
Height130 mm
Depth115 mm
Horizontal pitch1.8 Div.
Installation dimensions
Installation distance right/left0 mm / 0 mm
Installation distance top/bottom50 mm / 50 mm

Mounting
Mounting typeDIN rail mounting
Assembly notealignable: horizontally 0 mm, vertically 50 mm
Mounting positionhorizontal DIN rail NS 35, EN 60715

Material specifications
Housing materialMetal
Housing materialSteel sheet, zinc-plated
Type of housingSteel sheet, zinc-plated
Side element versionAluminum

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 55° C derating : 2.5%/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Climatic class3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock15g in all directions in acc. with IEC 60068-2-27
Vibration (operation)
15 Hz ... 150 Hz, 2.3g tv= 90 min.

Standards and regulations
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard - Electrical safetyEN 60950-1/VDE 0805 (SELV)
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipmentEN 50178
Standard – Safety extra-low voltageIEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard - Safe isolationDIN VDE 0100-410

Approvals
UL approvalsUL/C-UL listed UL 508
UL/C-UL Recognized UL 60950-1

EMC data
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emissionEN 61000-6-3
EN 61000-6-4
EMC requirements for noise immunityEN 61000-6-1
EN 61000-6-2
Electrostatic discharge
Standards/regulationsEN 61000-4-2
HousingLevel 3
Electrostatic discharge
Contact discharge6 kV (Contact discharge)
Discharge in air8 kV (Air discharge)
CommentsCriterion B
Electromagnetic HF field
Standards/regulationsEN 61000-4-3
Electromagnetic HF field
Frequency range80 MHz ... 3 GHz
Test field strength10 V/m
CommentsCriterion A
Fast transients (burst)
Standards/regulationsEN 61000-4-4
Fast transients (burst)
Input2 kV (level 3 - asymmetrical: conductor to ground)
Output2 kV (level 3 - asymmetrical: conductor to ground)
CommentsCriterion B
Surge voltage load (surge)
Standards/regulationsEN 61000-4-5
Surge voltage load (surge)
Input2 kV (level 3 - asymmetrical: conductor to ground)
1 kV (Level 2 - symmetrical: Conductor to conductor)
Output2 kV (level 3 - asymmetrical: conductor to ground)
1 kV (Level 2 - symmetrical: Conductor to conductor)
CommentsCriterion B
Conducted interference
Standards/regulationsEN 61000-4-6
Conducted interference
Input/OutputLevel 3
Frequency range150 kHz ... 80 MHz
CommentsCriterion A
Voltage10 V
Emitted interference
Standards/regulationsEN 61000-6-3
Radio interference voltage in acc. with EN 55011EN 55011 (EN 55022) Class B, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011EN 55011 (EN 55022) Class B, area of application: Industry and residential

ETIM for 2866514 Low-voltage industrial controls and switchgear (EC000683)

Feature nameFunction (EF000030)
Feature valueOther
Feature nameVoltage type (operating voltage) (EF005294)
Feature valueDC
Feature nameOperating voltage DC (EF008208)
Feature value12 V
Feature nameWith LED indication (EF005950)
Feature valueYes

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.