IBS IL 24 BK-LK/45-PAC 2862165 PHOENIX CONTACT Bus coupler

Reference: IBS IL 24 BK-LK/45-PAC

Code: 2862165

Manufacturer: PHOENIX CONTACT

Description:

Bus coupler
Inline, Bus coupler, INTERBUS, F-SMA connector, 45° inclined fibre optic cable connection, local bus transmission rate:500 kBit/s, protection rating: IP20, including Inline connector and marking surface

Categories:

  • PHOENIX CONTACT > I/O

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT

  • More Info
  • PDF
  • Reviews
Guarantee, repair and return.

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

LAST VIEWED

MORE INFO

Key Commercial Data

Orderkey2862165
Packing unit1 pc
Catalog pagePage 131 (C-6-2017)
GTIN4017918894658
Weight per Piece (excluding packing)210.000 g
Custom tariff number85389091
Country of originDE (Germany)

Note

Utilization restriction1

Dimensions

Dimensional drawing
Width85 mm
Height119.8 mm
Depth71.5 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)75 % ... 85 %
Permissible humidity (storage/transport)75 % ... 85 %
Air pressure (operation)80 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

General

Mounting typeDIN rail
Net weight210 g
Note on weight specificationswithout plug

Interfaces

DesignationINTERBUS
No. of channels2
Connection methodF-SMA connector
Note on the connection methodslanted
Transmission speed500 kbps
Transmission physicsFO
DesignationInline local bus
Connection methodInline data jumper
Transmission speed500 kbps

System limits of the bus coupler

Number of local bus devices that can be connectedmax. 63
Number of devices with parameter channel62
Number of supported branch terminals with remote bus branchmax. 15

Inline potentials

DesignationBus coupler supply UBC; Communications power UL(7.5 V) and the analog supply UANA(24 V) are generated from the bus coupler supply.
Supply voltage24 V DC (via Inline connector)
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumptiontyp. 90 mA (without connected Inline I/O terminals)
max. 1.25 A (with max. number of connected I/O terminal blocks)
DesignationCommunications power (UL)
Supply voltage7.5 V DC ±5 %
Power supply unitmax. 2 A DC (observe derating)
DesignationSupply of analog modules (UANA)
Supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Power supply unitmax. 0.5 A DC (observe derating)

Electrical isolation

Test section7.5 V communications power, 24 V analog supply, 24 V bus coupler supply/functional earth ground 500 V AC 50 Hz 1 min.

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.