PHOENIX CONTACT  FB-2SP 2316051 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

FB-2SP 2316051 PHOENIX CONTACT Device coupler

Reference: FB-2SP

Code: 2316051

Manufacturer: PHOENIX CONTACT

Description:

Device coupler
Device coupler for Foundation Fieldbus and PROFIBUS-PA expansions with connections for 2 splice taps with fieldbus devices

Categories:

  • PHOENIX CONTACT > Safety

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT

  • More Info
  • PDF
  • Reviews
Guarantee, repair and return.

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

  • These delivery times are an estimate any may vary when the item order has been processed.

MORE INFO

Key Commercial Data

Orderkey2316051
Packing unit1 pc
Catalog pagePage 425 (C-8-2015)
GTIN4046356466158
Weight per Piece (excluding packing)99.760 g
Custom tariff number85369095
Country of originUS (United States)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Dimensional drawing
Width17.5 mm
Height89.7 mm
Depth70.4 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 85 °C (depending on set rated current)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Degree of protectionIP20

General

Mounting positionOn horizontal DIN rail NS 35 in acc. with EN 60715
Net weight99.76 g
Housing materialPA 6.6-FR
Colorgreen
ConformanceCE-compliant, additionally EN 61326
Fieldbus FoundationFF-846

Power supply

Supply voltage range10.3 V DC ... 32 V DC (input on trunk line side)
Typical current consumption6 mA

Serial interface

Interface 1Foundation Fieldbus and PROFIBUS PA Segment
No. of ports2
Connection methodPluggable COMBICON screw connection for each spur
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Output nominal voltage≤ 32 V (each spur)
Output current15 mA (each spur, adjustable via selector switch, -40 ... 85°C)
25 mA (each spur, adjustable via selector switch, -40...80°C)
35 mA (each spur, adjustable via selector switch, -40...75°C)
45 mA (each spur, adjustable via selector switch, -40...70°C)
Maximum output current22 mA (each spur, adjustable via selector switch, -40 ... 85°C)
33 mA (each spur, adjustable via selector switch, -40...80°C)
45 mA (each spur, adjustable via selector switch, -40...75°C)
57 mA (each spur, adjustable via selector switch, -40...70°C)
Inductance Li4 µH
Max. output voltage UoUi

Safety data

Max. output voltage UoUi
Max. output current Io48 mA
Max. output power Po1.536 W
GroupIIB
Max. external capacity Co100 nF
GroupIIB
Max. external inductivity Lo325 µH
ATEXSira 08ATEX4303X: II 3(3)G
Ex nA [Ic Gc] IIB T4 Gc, FISCO Ic spurs
Ex nA [nL Gc] IIB T4 Gc, FNICO spurs
IECExIECEx SIR 08.0110X: II 3(3)G
Ex nA [Ic Gc] IIB T4 Gc, FISCO Ic spurs
Ex nA [nL Gc] IIB T4 Gc, FNICO spurs
CSA, USA/CanadaClass I, Div. 2, Groups C, D
Ex nA [nL] IIB T4, FNICO/Entity
Class I, Zone 2, AEx nA [nL] IIB T4, FNICO/Entity

Standards and Regulations

Type of testCorrosive resistance in acc. to ANSI-ISA 71.04-1985 - Severity level G3
DesignationStandards/regulations
Standards/regulationsRing wave noise immunidty in acc. with IEC 61000-4-12
DesignationStandards/regulations
Standards/regulationsDry heat in acc. with IEC 61131-2
DesignationStandards/regulations
Standards/regulationsDamp heat in acc. with IEC 61131-2
DesignationStandards/regulations
Standards/regulationsShock and vibration in acc. with EN 61131-2 and EN 50178
IEC 61158-2
IEC 60529, IEC 61158-2
NE21
EN 61326, EN 60068-2-27, EN 60068-2-6
FF-846
Shock15g, 11 ms
Vibration (operation)1g, 10 Hz ... 150 Hz
ConformanceCE-compliant, additionally EN 61326
Fieldbus FoundationFF-846
GroupIIB
IIB
ATEXSira 08ATEX4303X: II 3(3)G
Ex nA [Ic Gc] IIB T4 Gc, FISCO Ic spurs
Ex nA [nL Gc] IIB T4 Gc, FNICO spurs
IECExIECEx SIR 08.0110X: II 3(3)G
Ex nA [Ic Gc] IIB T4 Gc, FISCO Ic spurs
Ex nA [nL Gc] IIB T4 Gc, FNICO spurs
CSA, USA/CanadaClass I, Div. 2, Groups C, D
Ex nA [nL] IIB T4, FNICO/Entity
Class I, Zone 2, AEx nA [nL] IIB T4, FNICO/Entity

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

DATASHEET - PDF

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.