OBO BETTERMANN FRD 110 5098557 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

FRD 110 5098557 OBO BETTERMANN Lightning barrier with decoupling resistance, 110V AC,

Reference: FRD 110

Code: 5098557

Manufacturer: OBO BETTERMANN

Description:

Lightning barrier with decoupling resistance, 110V AC,
Medium and fine protection FRD for two-core systems 110 V. Surge protection for use in measurement and control technology • Medium and fine protection • Standard design for double core systems • Two-stage protection circuit • With installation-friendly, screwless connection terminals • In space-saving 17.5 mm grid • With ohmic decoupling in the longitudinal branchApplication: Universal use on any 35 mm DIN profile rail in every commercially available distributor housing.

Categories:

  • Earthing, lightning and surge protection > Combined arrester for data networks/MCR-technology
  • OBO BETTERMANN > TBS Transient and lightning protection systems - OBO BETTERMANN > Surge protection, arrestor, type 3 - OBO BETTERMANN

Brand new product in its original packaging covered by the warranties and certifications provided by OBO BETTERMANN

  • More Info
  • PDF
  • Reviews
Guarantee, repair and return.

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

LAST VIEWED

MORE INFO

ApprovalsUL
Arrestor monitoringno
Capacity (wire-earth)<1 nF
Capacity (wire-wire)<10 nF
CO2 Footprint (GWP) Cradle-to-Gate0,1805 kg CO2e / 1 Piece
Connection cross-section, flexible, max.2,5 mm²
Connection cross-section, flexible, min.0,14 mm²
Connection cross-section, multi-wire, max.2,5 mm²
Connection cross-section, multi-wire, min.0,14 mm²
Connection cross-section, rigid, max.2,5 mm²
Connection cross-section, rigid, min.0,14 mm²
Cut-off frequency3,6 MHz
Dimension110V AC
Division unit TE (17.5 mm)1
Earthing via:Terminal
Explosion-tested versionno
Impulse durability wire-earthC2: 10 kV / 5 kA
Impulse durability wire-wireC2: 5 kV / 2,5 kA (8/20µs)
Insertion loss3 dB @ 3,6 MHz dB
Insulation resistance>100 MΩ
KategorieType 1+2+3 / D1+C2+C1
Lightning impulse current1,5 kA
Lightning protection zone LPZ0→3
Maximum continuous voltage AC86 V
Maximum continuous voltage DC122 V
Nominal discharge current (8/20 µs)5 kA
Nominal load current AC0,14 A
Nominal load current DC0,2 A
Nominal voltage110 V
Number of poles2
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Plug-in systemTerminal
Protection level wire-earth<600 V
Protection level wire-wire<300 V
Protection ratingIP20
Series resistance per wire15 Ω ± 10 %
Shielding connection availableno
SPD to IEC 61643-21Class I+II+III / D1+C2+C1
Telecommunications contactno
Testing standardIEC 61643-21
Total discharge current (10/350)D1: 3 kA
Total discharge current (8/20)10 kA

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.