Shunt release for NZM2/3, 1 early-make auxiliary contact, 2NO, 48AC/DC, Push-in terminals

Подробнее


Автоматические выключатели в литом корпусе NZM

* Новый продукт в оригинальной упаковке со всеми гарантиями и сертификатами EATON-MOELLER

Кол-во цена
1+$112.90
2+$101.81
*Эта цена за единицу и является чистая стоимость (не включая налоги, если это применимо).

Если наша цена не самая лучшая, попросите нас о цене бюджетный запрос

ПРОСМОТРЕННЫЕ ТОВАРЫ


Best sellers

Описание



Shunt release for NZM2/3, 1 early-make auxiliary contact, 2NO, 48AC/DC, Push-in terminals
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: Shunt releases with one early-make contact and push-in terminals. Switches are tripped by a voltage pulse or by the application of uninterrupted voltage. When the shunt release is live, contact with the circuit-breaker's main contacts on switching on is reliably prevented. Early-make of auxiliary contacts on switching on and off (manual operation): approx. 20 ms (NZM2/3) and 90 ms (NZM4) . Shunt release modules cannot be installed simultaneously with early-make contact NZM…-XHIV, untervoltage release NZM…-XU…, relais modules NZM...-X2A..., or remote operator NZM...-XR...

General specifications
Product name
Eaton Moeller series NZM - Molded Case Circuit Breaker
Part no.
NZM2/3-XAHIV48AC/DC-PI
EAN
4015081878079
Product Length/Depth
115 millimetre
Product height
65 millimetre
Product width
75 millimetre
Product weight
0.08 kilogram
Compliances
UL/CSA
IEC
RoHS conform
Product Tradename
NZM
Product Type
Molded Case Circuit Breaker
Product Sub Type
None
Delivery program
Type
AccessoryShunt release
Special features
When the shunt release is live, contact with the circuit-breaker's main contacts on switching on is reliably prevented.Early-make of auxiliary contacts on switching on and off (manual operation): approx. 20 ms (NZM2/3) and 90 ms (NZM4).Shunt release modules cannot be installed simultaneously with early-make contact NZM…-XHIV, untervoltage release NZM…-XU…, relais modules NZM...-X2A..., or remote operator NZM...-XR...
Frame
NZM2/3
Fitted with:
Early-make auxiliary contact
Suitable for
Motor safety switch
Off-load switch
Used with
NZM2(-4), N(S)2(-4)
NZM3(-4), N(S)3(-4)
Technical Data - Electrical
Voltage type
AC/DC
Rated control supply voltage
48 V AC/DC
Rated control supply voltage (Us) at AC, 50 Hz - min
48 V
Rated control supply voltage (Us) at AC, 50 Hz - max
48 V
Rated control supply voltage (Us) at AC, 60 Hz - min
48 V
Rated control supply voltage (Us) at AC, 60 Hz - max
48 V
Rated control supply voltage (Us) at DC - min
48 V
Rated control supply voltage (Us) at DC - max
48 V
Electric connection type
Spring clamp connection
Technical Data - Mechanical
Number of contacts (change-over contacts)
0
Number of contacts (normally closed contacts)
0
Number of contacts (normally open contacts)
1
Connection type
With push in terminal
Special features
When the shunt release is live, contact with the circuit-breaker's main contacts on switching on is reliably prevented.Early-make of auxiliary contacts on switching on and off (manual operation): approx. 20 ms (NZM2/3) and 90 ms (NZM4).Shunt release modules cannot be installed simultaneously with early-make contact NZM…-XHIV, untervoltage release NZM…-XU…, relais modules NZM...-X2A..., or remote operator NZM...-XR...
Design verification as per IEC/EN 61439
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 8.0

Low-voltage industrial components (EG000017) / Shunt release (for power circuit breaker) (EC001023)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Full load current trip ([email protected] [AKF016013])
Rated control supply voltage Us at AC 50HZ
48 - 48 V
Rated control supply voltage Us at AC 60HZ
48 - 48 V
Rated control supply voltage Us at DC
48 - 48 V
Voltage type for actuating
AC/DC
Initial value of the undelayed short-circuit release - setting range
0 A
End value adjustment range undelayed short-circuit release
0 A
Type of electric connection
Spring clamp connection
Number of contacts as normally open contact
1
Number of contacts as normally closed contact
0
Number of contacts as change-over contact
0
Suitable for power circuit breaker
No
Suitable for off-load switch
Yes
Suitable for motor safety switch
Yes
Suitable for overload relay
No

Datasheet - PDF

Заглавие: Размер: Тип:
PDF CATALOGUE EATON EN.pdf 51 Mbytes
NZM2/3-XAHIV48AC/DC-PI Y7-189812 189812 RU_189812.pdf 112 Kbytes   NZM2/3-XAHIV48AC/DC-PI Y7-189812 189812 RU_189812.pdf

Отзывы: (0)

Там нет Отзывы о товаре пока нет.

Добавить отзыв
скрыть форму
Рейтинг:
Имя:
Эл. адрес:
Предмет:
Текст:
  Captcha
  Добавить отзыв

Все оценки, которые мы получаем о артикулах, которые мы предлагаем, являются реальными и проверенными. Маленький жест, но очень ценный. Вот почему мы благодарим Вас за ту минуту, которую Вы инвестируете в то, чтобы оставить нам свое мнение о продуктах, это помогает нам продолжать совершенствоваться и предлагать Вам услугу еще более высокого качества.