Product name
Eaton Moeller® series EASY I/O expansion
Product Length/Depth
58 millimetre
Product height
90 millimetre
Product width
36 millimetre
Product weight
0.125 kilogram
Compliances
Contact Manufacturer
Certifications
CULus per UL 61010
IEC 60068-2-27
IEC/EN 61000-6-3
IEC/EN 61131-2
CSA-C22.2 No. 61010
EN 61010
IEC 60068-2-30
IEC/EN 61000-4-2
EN 50178
IEC/EN 61000-6-2
IEC 60068-2-6
UL File No.: E205091
DNV GL
UL Listed
CE
UL Category Control No.: NRAQ, NRAQ7
UL hazardous location division 2
UL hazardous location group B (hydrogen)
UL hazardous location group D (propane)
UL hazardous location group C (ethylene)
UL hazardous location class I
UL hazardous location group A (acetylene)
Product Type
I/O expansion
Catalog Notes
fitted with two controlled relays
Features
Expandable
Expansion device
Indication
LCD-display base unit used as status indication of Digital inputs 12 V DC
LCD-display base unit used as status indication of Digital inputs 24 V DC
Input frequency
50/60 Hz (Digital inputs, at 24 V DC)
Insulation resistance
According to EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201
Lifespan, electrical
25,000 Operations (Filament bulb load at 500 W, 115/120 V AC)
25,000 Operations (Fluorescent lamp load 10 x 58 W at 230/240 V AC, uncompensated)
25,000 Operations (Fluorescent lamp load 1 x 58 W at 230/240 V AC, conventional, compensated)
25,000 Operations (Fluorescent lamp load 10 x 58 W at 230/240 V AC, with upstream electrical device)
25,000 Operations (Filament bulb load at 1000 W, 230/240 V AC)
Lifespan, mechanical
10,000,000 Operations
Mounting method
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Rail mounting possible
Screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Wall mounting/direct mounting
Front build in possible
Product category
Control relays easyE4
Protection
B16 circuit breaker or 8 A (T) fuse, Protection of an Output relay
Rated impulse withstand voltage (Uimp)
6 kV (contact-coil)
Software
EASYSOFT-SWLIC/easySoft7
Switching frequency
2 Hz, Resistive load/lamp load, Relay outputs
10 Hz, Relay outputs
0.5 Hz, Inductive load, Relay outputs
Utilization category
B 300 Light Pilot Duty, UL/CSA Control Circuit Rating Codes AC
R 300 Light Pilot Duty, UL/CSA Control Circuit Rating Codes DC
Ambient conditions, mechanical
Drop and topple
50 mm Drop height, Drop to IEC/EN 60068-2-31
Height of fall (IEC/EN 60068-2-32) - max
0.3 m
Mounting position
Vertical
Horizontal
Shock resistance
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 18 Impacts
Vibration resistance
According to IEC/EN 60068-2-6
10 - 57 Hz, 0.15 mm constant amplitude
57 - 150 Hz, 2 g constant acceleration
Climatic environmental conditions
Air pressure
795 - 1080 hPa (operation)
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
55 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
70 °C
Environmental conditions
Condensation: prevent with appropriate measures
Clearance in air and creepage distances according to EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201
Relative humidity
5 - 95 % (IEC 60068-2-30, IEC 60068-2-78)
Electro magnetic compatibility
Burst impulse
2 kV, Signal cable
2 kV, Supply cable
According to IEC/EN 61000-4-4
Electromagnetic fields
1 V/m at 2.0 - 2.7 GHz (according to IEC EN 61000-4-3)
3 V/m at 1.4 - 2 GHz (according to IEC EN 61000-4-3)
10 V/m at 0.8 - 1.0 GHz (according to IEC EN 61000-4-3)
Immunity to line-conducted interference
10 V (according to IEC/EN 61000-4-6)
Radio interference class
Class B (EN 61000-6-3)
Surge rating
2 kV, Supply cables, asymmetrical, power pulses (Surge), EMC
1 kV, Supply cables, symmetrical, power pulses (Surge), EMC
According to IEC/EN 61000-4-5, power pulses (Surge), EMC
Voltage dips
≤ 1 ms from rated voltage (12 V DC)
10 ms
Terminal capacity
0.2 - 4 mm² (AWG 22 - 12), solid
0.2 - 2.5 mm² (22 - 12 AWG), flexible with ferrule
Screwdriver size
3.5 x 0.8 mm, Terminal screw
Tightening torque
0.6 Nm, Screw terminals
Conventional thermal current ith of auxiliary contacts (1-pole, open)
8 A
Rated breaking capacity
300000 Operations at AC-15, 250 V AC, 3 A (600 Ops./h)
200000 Operations at DC-13, 24 V DC, 1 A (500 Ops./h)
Rated insulation voltage (Ui)
240 V
Rated operational voltage
Max. 300 V AC
24 V AC (digital inputs)
12/24 V DC (-15 %/+ 20 % - power supply)
Max. 300 V DC
10.2 - 28.8 V DC
240 V AC
24 V DC (digital inputs)
24 V AC (-15 %/+10 % - power supply)
12 V DC (digital inputs)
20.4 - 26.4 V AC
Supply frequency
50/60 Hz (± 5%)
Supply voltage at AC, 50 Hz - min
85
Supply voltage at AC, 50 Hz - max
264
Supply voltage at DC - min
10.2
Supply voltage at DC - max
28.8
Uninterrupted current
8 A DC, at 24 V DC (UL/CSA)
10 A AC, at 240 V AC (UL/CSA)
1 A DC, at R 300 (UL/CSA)
5 A AC, max. thermal continuous current cos ϕ = 1 at B 300 (UL/CSA)
Short-circuit protection
≥ 1A (T), Fuse, Power supply
Connection type
Screw terminal
Cable length
100 m, unscreened, Digital inputs 24 V AC
100 m, unscreened, Digital inputs 24 V DC
100 m, unscreened, Digital inputs 12 V DC
40 m (max. per input), Digital inputs 24 V DC
Delay time
25 ms typ., Digital Inputs 24 V AC 50 Hz (I1 - I4), Delay time from 0 to 1, Debounce OFF
0.015 ms typ., Digital inputs 12 V DC (I1 - I8), Delay time from 0 to 1, Debounce OFF
0.015 ms typ., Digital inputs 12 V DC (I1 - I8), Delay time from 1 to 0, Debounce OFF
20 ms, Digital Inputs 12 V DC, Delay time from 1 to 0, Debounce ON
0.1 ms typ., Digital inputs 24 V DC (I1 - I4), Delay time from 0 to 1, Debounce OFF
25 ms typ., Digital Inputs 24 V AC 50 Hz (I1 - I4), Delay time from 1 to 0, Debounce OFF
21 ms typ., Digital Inputs 24 V AC 60 Hz (I1 - I4), Delay time from 0 to 1, Debounce OFF
21 ms typ., Digital Inputs 24 V AC 60 Hz (I1 - I4), Delay time from 1 to 0, Debounce OFF
20 ms, Digital Inputs 12 V DC, Delay time from 0 to 1, Debounce ON
0.2 ms typ., Digital inputs 24 V DC (I1 - I4), Delay time from 1 to 0, Debounce OFF
Input current
3.3 mA (I1 - I4, at 24 V DC, at signal 1)
80 mA
Input voltage
Signal 0: ≤ 5 V DC (I1 - I4, Digital inputs, 12 V DC)
Signal 1: ≥ 15 V DC (I1 - I4, Digital inputs, 24 V DC)
At signal 0: ≤ 5 V (I1 - I8, sinusoidal, Digital inputs, 24 V DC)
Signal 0: ≤ 5 V DC (I1 - I4, Digital inputs, 24 V DC)
At signal 1: ≥ 15 V (I1 - I8, sinusoidal, Digital inputs, 24 V DC)
Status 0: ≤ 15 V DC (I1 - I4, Digital inputs, 24 V DC)
Making/breaking capacity
28/28 VA (DC, at R 300)
3600/360 VA (AC, at B 300)
Number of inputs (analog)
0
Number of inputs (digital)
4
Number of outputs (analog)
0
Number of outputs (digital)
4
Output
Relay outputs in groups of 1
4 Relay Outputs
> 500 mA (Relay outputs, Recommended for load: 12 V AC/DC)
Voltage
Current
Parallel switching
Not permitted
Explosion safety category for gas
None
Potential isolation
Between Relay outputs: yes
Between Relay outputs and expansion devices: yes
Between Digital inputs 24 V DC and Outputs: yes
Between Digital inputs 12 V DC and expansion devices: yes
Between Digital inputs 24 V AC and expansion devices: yes
Between Digital inputs 24 V AC and base unit: yes
Between Digital inputs 12 V DC and base unit: yes
Between Digital inputs 24 V DC and expansion devices: yes
Safe isolation according to EN 50178: 300 V AC (Relay outputs)
Between Relay outputs and Power supply: yes
Between Digital inputs 12 V DC and Outputs: yes
Between Digital inputs 24 V AC and Outputs: yes
Between Digital inputs 24 V DC and base unit: yes
Between Relay outputs and Inputs: yes
Basic isolation: 600 V AC (Relay outputs)
Protection against polarity reversal
Yes, for supply voltage (Siemens MPI optional)
Explosion safety category for dust
None
Safe isolation
300 V AC, Between coil and contact, According to EN 50178
300 V AC, Between two contacts, According to EN 50178
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
2 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.