Description:

Selected parameters FUNCTION Input/Output unit for Eos-Array, antitheft compability MOUNTING DIN-rail OUTPUT INPUT PORT Digital input, Relay output COMMUNICATION None Others RANGE None DISPLAY None VIARIABLES None NUMBER OF INPUTS 3 NUMBER OF OUTPUTS 1 POWER SUPPLY None
I/O Unit For Antitheft Application

Categories:

  • CARLO GAVAZZI

Brand new product in its original packaging covered by the warranties and certifications provided by CARLO GAVAZZI

  • More Info
  • Reviews
Guarantee, repair and return.

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

  • These delivery times are an estimate any may vary when the item order has been processed.

MORE INFO

Energy Management
Control solution for solar PV applications
Type Eos-Array
• Modular local control system for PV plants
• Up to 17 DIN modules configuration equivalent to 280mm width
• Eos-ArraySoft freeware software for easy product configuration
• Eos-Array can be formed by maximum 17 units
• Eos-Array can manage in addition to VMU-M master unit up to:
- 1 VMU-P unit
- max 15 VMU-S units
- max 7 VMU-O units
- max 1 VMU-1.
VMU-M, master module and data logger
• Master communication capability
• RS485 communication port (Modbus)
• Local communication bus management up to 15 mixed
VMU-S, VMU-P and VMU-O units
• Two digital inputs
• Two temperature inputs: Pt100 or Pt1000
• Single virtual or real alarm set-point connectable to any available variable
• Data and event stamping system
• Display readout: 6 DGTs
• 12 to 28 VDC power supply
• Dimensions: 1-DIN module
• Protection degree (front): IP40
Product Description
How to orderVMU-M4 A S1 T2 X
Eos-Array isa combination of moduleswhichperforms a complete control of a pho- tovoltaic plant. The core unit isVMU-Mwhichperforms thelocalbusmanagement of VMU-S, VMU-P both measuring units and VMU-O I/Ounit.VMU-M assigns the proper local unit address automatically (up to 15 units) and gathers all the local measurements comingfrom VMU-S and VMU-P measur- ingunits.VMU-Mcanpro-
vide by means of VMU-O modulestworelay outputs so to manage alarms or/and external loads (like a lighting system,a modulewashing system and so on) and two temperature inputs. These latter two measuring inputs can become, according to the programmed function, also two digital inputs. Housing for DIN-rail mount- ing, IP40 (front) protection degree.
Model Function Power supply
Communication
Inputs
Option
Type Selection
Function
4: Data storage
4Mbyte (*)
Option
Power supply
A:From 12 to 28VDC
(*)
Communication
S1: RS485 Modbus (*)
Inputs
T2:two temperature inputs or two digital inputs for free of voltage reading contacts (*)
(*) as standard.
X:none
Specifications are subject to change without notice Eos-Array DS 250214 1

DATASHEET - PDF

Title
Size
Type

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.