ABB 1SAM360000R1007 1SAM360000R1007 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

1SAM360000R1007 ABB MO132-2.5 Manual Motor Starter Magnetic Only

Reference: 1SAM360000R1007

Manufacturer: ABB

Description:

MO132-2.5 Manual Motor Starter Magnetic Only
MO132-2.5 SINGLE MAGNETIC 2.5 MOTOR GUARD
MO132-2.5 Manual Motor Starter Magnetic Only 2.5 A

Categories:

  • Low-voltage industrial components > Motor protection circuit-breaker
  • ABB > Electronic motor protection relays > Electronic motor protection relays Mx116 and Mx132

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

Unit Price: 46,61 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 7-8 days.

  • These delivery times are an estimate any may vary when the item order has been processed.

LAST VIEWED

MORE INFO

Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85362010
Popular Downloads
Data Sheet, Technical Information2CDC131035D0202
Instructions and Manuals2CDC131034M6801
Instructions and Manuals (Part 2)2CDC131060M0202
Time-Current Characteristic Curve1SAM300515F0105
I²t Characteristic1SAM300507F0001
1SAM300507F0003
Cut-off Current Characteristic1SAM300508F0001
1SAM300508F0003
CAD Dimensional Drawing2CDC001079B0201
Dimension Diagram1SAM300402F0001
Dimensions
Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length86.75 mm
Product Net Weight0.265 kg
Technical
Rated Service Short-Circuit Breaking Capacity (Ics)(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(690 V AC) 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(690 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)31.3 A
Setting RangeNone
Rated Operational Power AC-3 (Pe)(400 V) Three Phase 0.75 kW
Rated Operational Power AC-3e (Pe)(400 V) Three Phase 0.75 kW
Rated Operational VoltageMain Circuit 690 V AC
Rated Operational Current (Ie)2.5 A
Rated Operational Current AC-3 (Ie)2.5 A
Rated Operational Current AC-3e (Ie)2.5 A
Rated Frequency (f)Main Circuit 50 Hz
Main Circuit 60 Hz
Operating Frequency (fsw)0 ... 400 Hz
Rated Impulse Withstand Voltage (Uimp)Main Circuit 6 kV
Rated Insulation Voltage (Ui)690 V
Power Lossat Rated Operating Conditions per Pole 1.7 W
Number of Poles3P
Conventional Free-air Thermal Current (Ith)Main Circuit 2.5 A
Degree of ProtectionHousing IP20
Main Circuit Terminals IP10
Pollution Degree3
Electrical Durability50000 cycle
Mechanical DurabilityNr. Operations 100000 cycle
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Tightening TorqueMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Recommended Screw DriverPozidriv 2
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Actuator TypeRotary Handle
Contact Position IndicationON / OFF / TRIP
StandardsIEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
RemarksFor overload protection of the motors, an appropriate thermal or electronic overload relays must be used
Technical UL/CSA
Short-Circuit Current Rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 47 kA
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Horsepower Rating UL/CSA(200 V AC) Three Phase 0.5 Hp
(208 V AC) Three Phase 0.5 Hp
(220 ... 240 V AC) Three Phase 0.5 Hp
(440 ... 480 V AC) Three Phase 1 Hp
(550 ... 600 V AC) Three Phase 1.5 Hp
Full Load Amps Motor Use(200 V AC) Three Phase 2.5 A
(208 V AC) Three Phase 2.5 A
(220 ... 240 V AC) Three Phase 2.5 A
(440 ... 480 V AC) Three Phase 2.5 A
(550 ... 600 V AC) Three Phase 2.5 A
Locked Rotor Amps(200 V AC) Three Phase 15 A
(208 V AC) Three Phase 15 A
(220 ... 240 V AC) Three Phase 15 A
(440 ... 480 V AC) Three Phase 15 A
(550 ... 600 V AC) Three Phase 15 A
General Use Rating UL/CSA(600 V AC) 2.5 A
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Tightening Torque UL/CSAMain Circuit 10 in·lb
Environmental
Ambient Air TemperatureAround the Enclosure 0 ... +40 °C
Operation -25 ... +60 °C
Storage -50 ... +80 °C
Ambient Air Temperature CompensationNo
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 25g
Resistance to Vibrations5g 3 ... 150 Hz
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SAA963005-4502
RoHS Declaration1SAA963006-4501
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006539
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
End Of Life Disassembling Instructions1SAC200332H0001
Environmental Product Declaration - EPD1SAC200360H0001
Certificates and Declarations
A2L Certificate – IEC1SAA963000-4601
ABS Certificate1SAA963001-0101
BV Certificate1SAA963001-0202
CB Certificate1SAA963002-2002
1SAA963007-2002
CCC Certificate2024010307654702
2024010307658958
CQC CertificateCQC2010010307387700
CQC2019010307243864
Cut-off Current Characteristic1SAM300508F0001
1SAM300508F0003
Declaration of Conformity - CCC2020980307003526
2020980307003041
Declaration of Conformity - CE1SAD101100-3403
Declaration of Conformity - UKCA1SAD201100-3403
DNV GL Certificate1SAA963001-0304
EAC Certificate1SAA963000-2701
KC Certificate1SAA963002-1502
LR Certificate1SAA963001-0502
RINA Certificate1SAA963002-0802
RMRS Certificate1SAA918000-0704
UL CertificateE137861-20090225
E345003-20090225
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width92 mm
Package Level 1 Depth / Length95 mm
Package Level 1 Height50 mm
Package Level 1 Gross Weight0.28 kg
Package Level 1 EAN4013614400223
Package Level 2 Unitscarton 40 piece
Package Level 2 Width280 mm
Package Level 2 Depth / Length395 mm
Package Level 2 Height210 mm
Package Level 2 Gross Weight11.586 kg
Package Level 2 EAN4013614443671
External Classifications and Standards
Object Classification CodeF
ETIM 9EC000074 - Motor protection circuit-breaker
ETIM 10EC000074 - Motor protection circuit-breaker
eClassV11.0 : 27370401
UNSPSC39121521
IDEA Granular Category Code (IGCC)4731 >> Manual Starters
E-Number (Finland)3705885
E-Number (Norway)4364091
E-Number (Sweden)3110035

ETIM for 1SAM360000R1007 Low-voltage industrial controls and switchgear (EC000074)

Feature nameOverload release current setting (EF002336)
Feature value2.5 A
Feature nameAdjustment range undelayed short-circuit release (EF007131)
Feature value31.3 A
Feature nameWith thermal overload protection (EF006233)
Feature valueNo
Feature namePhase failure sensitive (EF007400)
Feature valueNo
Feature nameSwitch off technique (EF007007)
Feature valueMagnetic
Feature nameRated operating voltage (EF001435)
Feature value690 V
Feature nameRated permanent current Iu (EF001389)
Feature value2.5 A
Feature nameRated operation power at AC-3, 230 V (EF007025)
Feature value0.75 kW
Feature nameRated operation power at AC-3, 400 V (EF001364)
Feature value0.75 kW
Feature namePower loss (EF005387)
Feature value5.1 W
Feature nameType of electrical connection of main circuit (EF006819)
Feature valueScrew connection
Feature nameType of control element (EF006976)
Feature valueOther
Feature nameDevice construction (EF008240)
Feature valueComplete device in housing
Feature nameWith integrated auxiliary switch (EF001387)
Feature valueNo
Feature nameWith integrated under voltage release (EF001390)
Feature valueNo
Feature nameNumber of poles (EF001391)
Feature value3
Feature nameRated short-circuit breaking capacity Icu at 400 V, AC (EF007049)
Feature value100 kA
Feature nameDegree of protection (IP) (EF005474)
Feature valueIP20
Feature nameHeight (EF000040)
Feature value90 mm
Feature nameWidth (EF000008)
Feature value45 mm
Feature nameDepth (EF000049)
Feature value86.75 mm

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.