ANUNCIAR
M22-L-G-LED230-BVP 132600 Y7-132600 EATON ELECTRIC Indicatori luminosi, apparecchio completo Visualizza ingrandito
Le immagini sono solo per fini illustrativi. Si prega di fare riferimento alla scheda tecnica p...

M22-L-G-LED230-BVP 132600 Y7-132600 EATON ELECTRIC Indicatori luminosi, apparecchio completo

M22-L-G-LED230-BVP

132600

Y7-132600

EATON-MOELLER

Indicatori luminosi, apparecchio completo

Indicatore luminoso pieno 22 mm Verde 230 V AC Blister

Eaton Moeller® series M22 Indicator light, complete device M22-L-G-LED230-BVP, Blister pack for hanging

Spia di controllo, Gamma prodotti: RMQ-Titan, Descrizione: Blister da appendere., Soluzione pratica completa., Ordinabile con un solo codice articolo, Collegamento a SmartWire-DT: no

Maggiori dettagli


Apparecchi elettrici a bassa tensione > Lampada da quadro

Ausili di controllo e segnalazione

Prodotto nuovo nel suo imballaggio d'origine con tutte le garanzie e certificazioni de EATON-MOELLER

Prezzo totale: $24.38
Prezzo unitario: $24.38
Questo prezzo è per unità e mostra il valore netto ( escluse le imposte indirette se applicabile ).

Se il nostro prezzo non è il migliore, chiedici un preventivo Richiedi un preventivo

Related products

Comprati di solito insieme

Più venduti

Dettagli



General specifications

Product Name
Eaton Moeller® series M22 Indicator light
Catalog Number
132600
EAN
4015081295357
Product Length/Depth
30 mm
Product Height
210 mm
Product Width
130 mm
Product Weight
0.03 kg
Compliances
CE
Model Code
M22-L-G-LED230-BVP

Features & Functions

Bezel color
Chrome
Bezel material
Other
Lens color
Green

General

Degree of protection
NEMA 4X, 13
Degree of protection (front side)
IP67/IP69K
Opening diameter
22.5 mm
Overvoltage category
III
Pollution degree
3
Product category
RMQ-Titan
Rated impulse withstand voltage (Uimp)
4000 V AC
Size
Front diameter: 29.7 mm
Type
Indicator lights

Ambient conditions, mechanical

Mounting position
As required

Climatic environmental conditions

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
70 °C
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78

Electrical rating

Rated insulation voltage (Ui)
250 V

Contacts

Force for positive opening - min
0 N

Design verification

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Please enquire
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 132600 Apparecchi elettrici a bassa tensione (EC000223)
Caratteristica Valore
numero di segnalatori luminosi installabili (EF006669) 1
colore della lente (EF000207) verde
tipo di lente (EF006253) tondo
diametro del foro (EF000079) 22.5 mm
larghezza dell'apertura (EF004565) 0 mm
altezza dell'apertura (EF004778) 22.5 mm
con anello frontale (EF006014) No
materiale dell'anello frontale (EF005972) altro
colore dell'anello frontale (EF002429) cromo
versione della lente (EF008343) piatto
grado di protezione (IP), lato frontale (EF003118) IP67/IP69K
indice di protezione (NEMA) (EF011959) 4X, 13

Datasheet - PDF

Recensioni: (0)

Nessun commento per il momento.

Inserisci recensione
nascondi form
Valutazione:
Nome:
Email:
Titolo:
Testo:
  Captcha
  Inserisci recensione

Tutti i feedback che riceviamo dagli elementi che offriamo sono reali e verificati. Un piccolo gesto, ma di grande valore. Quindi grazie per quel minuto si spende in noi lasciare il vostro parere e punteggio sui prodotti, perché ci aiuta a continuare a migliorare e di offrire ancora maggiore qualità del servizio.