XTMF/PI/NZM3/800/350-DF 192832 EATON ELECTRIC DISJ, 3P EL,PROT MOTOR + CHARIOT

XTMF/PI/NZM3/800/350-DF

192832

EATON-MOELLER

DISJ, 3P EL,PROT MOTOR + CHARIOT

Matériel xEnergy

Plus de détails


Coffrets et armoires industriels

* Produit neuf dans son emballage d'origine avec toutes les garanties et les certifications émises par EATON-MOELLER

Prix total: $223.95
Prix unitaire: $223.95

Quantité Prix
1+$223.95
2+$217.93
*Ce prix est par unité et montre la valeur nette (excluant les taxes indirectes le cas échéant) .

Si notre prix n'est pas le meilleur, demandez-nous un devis. Demander un devis

Les plus vendus

En savoir plus



Circuit-breaker, 350 A, 3-pole, with electronic release for motor protection, withdrawable
Circuit-breaker NZM3, 3 pole, Rated current = rated uninterrupted current( In = Iu ): 350 A, Installation type: Withdrawable, Screw connection, Standard/Approval: IEC, Protective function: Motor protection
[

Delivery program

Product range
Circuit-breaker
Protective function
Motor protection
Standard/Approval
IEC
Installation type
Withdrawable
Release system
Electronic release
Construction size
NZM3
Description
IEC/EN 60947-4-1, IEC/EN 60947-2

The circuit-breaker fulfills all requirements for AC-3 switching category.


R.m.s. value measurement and “thermal memory”
Adjustable time delay setting to overcome current peaks tr at 6 x Ir also infinity (without overload releases)
All AC-3 rating data applies to direct switching by the circuit-breaker under normal operating conditions. If, for example, a contactor takes over AC-3 switching under normal operating conditions, the full rated uninterrupted current applies to the circuit-breaker, In = Iu.
Number of poles
3 pole
Standard equipment
Screw connection
Switching capacity
400/415 V 50 Hz [Icu]
70 kA
Rated current = rated uninterrupted current [In= Iu]
350 A
Setting range
Overload trip[Ir]
175 - 350 A
Short-circuit releases [Irm]Non-delayed [Ii= Inx …]
2 - 14
,

Technical data

General
Standards
IEC/EN 60947
Protection against direct contact
Finger and back of hand proof to VDE 0106 Part 100
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperatureAmbient temperature, storage
- 40 - + 70 °C
Ambient temperatureOperation
-25 - +70 °C
Mechanical shock resistance (10 ms half-sinusoidal shock) according to IEC 60068-2-27
20 (half-sinusoidal shock 20 ms) g
Safe isolation to EN 61140Between auxiliary contacts and main contacts
500 V AC
Safe isolation to EN 61140between the auxiliary contacts
300 V AC
Mounting position
Vertical and 90° in all directions
With XFI earth-fault release:
- NZM1, N1, NZM2, N2: vertical and 90° in all directions
with plug-in unit
- NZM1, N1, NZM2, N2: vertical, 90° right/left
with withdrawable unit:
- NZM3, N3: vertical, 90° right/left
- NZM4, N4: vertical
with remote operator:
- NZM2, N(S)2, NZM3, N(S)3, NZM4, N(S)4: vertical and 90° in all directions

Direction of incoming supply
as required
Degree of protectionDevice
In the operating controls area: IP20 (basic degree of protection)
Degree of protectionEnclosures
With insulating surround: IP40
With door coupling rotary handle: IP66
Degree of protectionTerminations
Tunnel terminal: IP10
Phase isolator and strip terminal: IP00
Other technical data (sheet catalogue)
Temperature dependency, Derating
Circuit-breakers
Rated current = rated uninterrupted current [In= Iu]
350 A
Rated surge voltage invariability [Uimp]Main contacts
8000 V
Rated surge voltage invariability [Uimp]Auxiliary contacts
6000 V
Rated operational voltage [Ue]
690 V AC
Overvoltage category/pollution degree
III/3
Rated insulation voltage [Ui]
1000 V
Use in unearthed supply systems
≦ 690 V
Switching capacity
Rated short-circuit making capacity [Icm]240 V [Icm]
220 kA
Rated short-circuit making capacity [Icm]400/415 V [Icm]
154 kA
Rated short-circuit making capacity [Icm]440 V 50/60 Hz [Icm]
143 kA
Rated short-circuit making capacity [Icm]525 V 50/60 Hz [Icm]
80 kA
Rated short-circuit making capacity [Icm]690 V 50/60 H [Ic]
50 kA
Rated short-circuit breaking capacity Icn[Icn]Icu to IEC/EN 60947 test cycle O-t-CO [Icu]240 V 50/60 Hz [Icu]
100 kA
Rated short-circuit breaking capacity Icn[Icn]Icu to IEC/EN 60947 test cycle O-t-CO [Icu]400/415 V 50/60 Hz [Icu]
70 kA
Rated short-circuit breaking capacity Icn[Icn]Icu to IEC/EN 60947 test cycle O-t-CO [Icu]440 V 50/60 Hz [Icu]
65 kA
Rated short-circuit breaking capacity Icn[Icn]Icu to IEC/EN 60947 test cycle O-t-CO [Icu]525 V 50/60 Hz [Icu]
36 kA
Rated short-circuit breaking capacity Icn[Icn]Icu to IEC/EN 60947 test cycle O-t-CO [Icu]690 V 50/60 Hz [Icu]
25 kA
Rated short-circuit breaking capacity Icn[Icn]Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]240 V 50/60 Hz [Ics]
100 kA
Rated short-circuit breaking capacity Icn[Icn]Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]400/415 V 50/60 Hz [Ics]
70 kA
Rated short-circuit breaking capacity Icn[Icn]Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]440 V 50/60 Hz [Ics]
65 kA
Rated short-circuit breaking capacity Icn[Icn]Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]525 V 50/60 Hz [Ics]
18 kA
Rated short-circuit breaking capacity Icn[Icn]Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]690 V 50/60 Hz [Ics]
6 kA
Rated short-circuit breaking capacity Icn[Icn]
Maximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit-breaker.
Rated short-time withstand currentt = 0.3 s [Icw]
3.3 kA
Rated short-time withstand currentt = 1 s [Icw]
3.3 kA
Utilization category to IEC/EN 60947-2
A
Lifespan, mechanical(of which max. 50 % trip by shunt/undervoltage release) [Operations]
15000
Lifespan, electricalAC-1400 V 50/60 Hz [Operations]
5000
Lifespan, electricalAC-1415 V 50/60 Hz [Operations]
5000
Lifespan, electricalAC-1690 V 50/60 Hz [Operations]
3000
Lifespan, electricalAC--3400 V 50/60 Hz [Operations]
2000
Lifespan, electricalAC--3415 V 50/60 Hz [Operations]
2000
Lifespan, electricalAC--3690 V 50/60 Hz [Operations]
2000
Lifespan, electricalMax. operating frequency
60 Ops/h
Total break time at short-circuit
< 10 ms
Terminal capacity
Standard equipment
Screw connection
Accessories required
NZM3-XAVS
Optional accessories
Box terminal
Tunnel terminal
connection on rear
Round copper conductorBox terminalSolid
2 x 16 mm2
Round copper conductorBox terminalStranded
1 x (35 - 240)
2 x (25-120) mm2
Round copper conductorTunnel terminalSolid
1 x 16 mm2
Round copper conductorTunnel terminalStranded1-hole
1 x (16 - 185) mm2
Round copper conductorBolt terminal and rear-side connectionDirect on the switchSolid
1 x 16
2 x 16 mm2
Round copper conductorBolt terminal and rear-side connectionDirect on the switchStranded
1 x (25 - 240)
2 x (25 - 240) mm2
Round copper conductorBolt terminal and rear-side connectionConnection width extensionConnection width extension
2 x 300 mm2
Al circular conductorTunnel terminalSolid
1 x 16 mm2
Al circular conductorTunnel terminalStrandedStranded
1 x (25 - 185)2)mm2
Al circular conductorTunnel terminalStrandedDouble hole
1 x (50 - 240)
2 x (50 - 240) mm2
Al circular conductorTunnel terminalStranded
2)Up to 240 mm² can be connected depending on the cable manufacturer.
Cu strip (number of segments x width x segment thickness)Box terminal [min.]
6 x 16 x 0.8 mm
Cu strip (number of segments x width x segment thickness)Box terminal [max.]
10 x 24 x 1.0
+ 5 x 24 x 1.0
(2 x) 8 x 24 x 1.0 mm
Cu strip (number of segments x width x segment thickness)Bolt terminal and rear-side connectionFlat copper strip, with holes [min.]
6 x 16 x 0.8 mm
Cu strip (number of segments x width x segment thickness)Bolt terminal and rear-side connectionFlat copper strip, with holes [max.]
10 x 32 x 1.0 + 5 x 32 x 1.0 mm
Cu strip (number of segments x width x segment thickness)Bolt terminal and rear-side connectionConnection width extension
(2 x) 10 x 50 x 1.0 mm
Copper busbar (width x thickness) [mm]Bolt terminal and rear-side connectionScrew connection
M10
Copper busbar (width x thickness) [mm]Bolt terminal and rear-side connectionDirect on the switch [min.]
20 x 5 mm
Copper busbar (width x thickness) [mm]Bolt terminal and rear-side connectionDirect on the switch [max.]
30 x 10
+ 30 x 5 mm
Copper busbar (width x thickness) [mm]Bolt terminal and rear-side connectionConnection width extensionConnection width extension [max.]
2 x (10 x 50) mm
Control cables
1 x (0.75 - 2.5)
2 x (0.75 - 1.5) mm2
,

Design verification as per IEC/EN 61439

Caractéristiques techniques pour la vérification de la conception
Courant assigné d'emploi pour indication de la puissance dissipée [In]
350 A
Puissance dissipée du matériel, fonction du courant [Pvid]
36.75 W
Température d’emploi min.
-25 °C
Température d’emploi max.
+70 °C
Certificat d'homologation IEC/EN 61439
10.2 Résistance des matériaux et des pièces10.2.2 Résistance à la corrosion
Les exigences de la norme produit sont respectées.
10.2 Résistance des matériaux et des pièces10.2.3.1 Résistance à la chaleur de l'enveloppe
Les exigences de la norme produit sont respectées.
10.2 Résistance des matériaux et des pièces10.2.3.2 Résistance Matières isolantes Chaleur normale
Les exigences de la norme produit sont respectées.
10.2 Résistance des matériaux et des pièces10.2.3.3 Résistance Matières isolantes Chaleur exceptionnelle
Les exigences de la norme produit sont respectées.
10.2 Résistance des matériaux et des pièces10.2.4 Résistance aux UV
Les exigences de la norme produit sont respectées.
10.2 Résistance des matériaux et des pièces10.2.5 Elevation
Sans objet du fait que l'ensemble de l'appareillage doit être évalué.
10.2 Résistance des matériaux et des pièces10.2.6 Essai de choc
Sans objet du fait que l'ensemble de l'appareillage doit être évalué.
10.2 Résistance des matériaux et des pièces10.2.7 Inscriptions
Les exigences de la norme produit sont respectées.
10.3 Degré de protection des enveloppes
Sans objet du fait que l'ensemble de l'appareillage doit être évalué.
10.4 Distances d'isolement et lignes de fuite
Les exigences de la norme produit sont respectées.
10.5 Protection contre les chocs électriques
Sans objet du fait que l'ensemble de l'appareillage doit être évalué.
10.6 Montage de matériel
Sans objet du fait que l'ensemble de l'appareillage doit être évalué.
10.7 Circuits électriques et raccordements internes
Sous la responsabilité du tableautier.
10.8 Raccordements pour conducteurs passés de l'extérieur
Sous la responsabilité du tableautier.
10.9 Propriétés d'isolement10.9.2 Tension de tenue à fréquence industrielle
Sous la responsabilité du tableautier.
10.9 Propriétés d'isolement10.9.3 Tension de tenue aux chocs
Sous la responsabilité du tableautier.
10.9 Propriétés d'isolement10.9.4 Test d'enveloppes en matière isolante
Sous la responsabilité du tableautier.
10.10 Echauffement
Le calcul de l'échauffement est sous la responsabilité du tableautier. Eaton fournit les données de puissance dissipée des appareils.
10.11 Tenue aux courts-circuits
Sous la responsabilité du tableautier. Les spécifications des appareils doivent être respectées.
10.12 Compatibilité électromagnétique
Sous la responsabilité du tableautier. Les spécifications des appareils doivent être respectées.
10.13 Fonctionnement mécanique
Au niveau de l'appareil, les conditions requises sont remplies dans la mesure où les instructions de la notice de montage (IL) sont prises en compte.
,

Technical data ETIM 7.0

Commutateurs basse tension (EG000017) / Disjoncteur pour protection de transformateur, de générateur et d'installation (EC000228)
Electricité, Electronique, Automatisation et Commande / Technique de commutation basse tension / Interrupteur de puissance (BT, < 1 kV) / Interrupteur de puissance de protection de transformateur, générateur et système ([email protected] [AJZ716013])
courant permanent nominal (Iu)
350 A
tension assignée (Ue)
690 - 690 V
courant de commutation de court-circuit limite nominal Icu à 400 V, 50 Hz
150 kA
réglage de courant du déclencheur de surcharge
175 - 350 A
plage de réglage du déclencheur de court-circuit retardé de courte durée
0 - 0 A
plage de réglage du déclencheur de court-circuit non retardé
700 - 4900 A
protection intégrée contre les mises à la terre accidentelles
non
type de raccordement du circuit principal
borne à vis
type de construction de l'appareil
technique de tiroir pour appareil encastré
adapté à un montage de profilés chapeaux
non
montage de profilés chapeaux en option
non
nombre de contacts auxiliaires à ouverture
0
nombre de contacts auxiliaires à fermeture
0
nombre de contacts auxiliaires à deux directions
0
relais de signalisation de déclenchement disponible
non
avec déclencheur à sous-tension
non
nombre de pôles
3
position du raccordement de circuit principal
arrière
position du raccordement de circuit principal
arrière
finition de l'élément d'actionnement
levier
appareil complet avec unité de protection
oui
commande motorisée intégrée
non
commande motorisée en option
oui
indice de protection (IP)
IP20
,

Characteristics

Characteristic curve
,

Dimensions

① Blow out area, minimum clearance to adjacent parts
② Minimum clearance to adjacent parts
]

Datasheet - PDF

Commentaires: (0)

Aucun commentaire sur le produit encore.

Écrire commentaire
Sous forme de peau
Score:
Nom:
Email:
Titre:
Commentaire:
  Captcha
  Écrire commentaire

Toutes les évaluations que nous recevons des articles que nous proposons sont réels et vérifiés. Un petit geste, mais très précieux. Je vous remercie pour cette minute que vous passez à nous laisser votre avis et note sur les produits, car il nous aide à continuer à améliorer et à offrir encore plus la qualité de service.