ANUNCIAR
XN-322-4AIO-U2 183181 Y7-183181 EATON ELECTRIC Analog I/O module, 2 analog inputs and 2 analog outputs, +/-1.. Agrandir l'image
Les images sont à titre illustratif. Svp, révisez la fiche technique.

XN-322-4AIO-U2 183181 Y7-183181 EATON ELECTRIC Analog I/O module, 2 analog inputs and 2 analog outputs, +/-1..

XN-322-4AIO-U2

183181

Y7-183181

EATON-MOELLER

Analog I/O module, 2 analog inputs and 2 analog outputs, +/-10 V, Uref

XN-322-4AIO-U2

Module mixte analogique avec 2 sorties analogiques -10 à +10 V (12 bits) et 4 entrées analogiques -10 à +10 V (16 bits) ou entrées potentiomètre (0-100%, sortie de référence (+10 V/10 mA)

Plus de détails


Commande industrielle API > Bus de terrain, périphérie déc. - module entrée/sortie analogique

Modules d'E / S distantes XN300

Produit neuf dans son emballage d'origine avec toutes les garanties et les certifications émises par EATON-MOELLER

Prix total: $380.89
Prix unitaire: $380.89
Ce prix est par unité et montre la valeur nette (excluant les taxes indirectes le cas échéant) .

Si notre prix n'est pas le meilleur, demandez-nous un devis. Demander un devis

Related products

Les plus vendus

En savoir plus



Spécifications générales

Product Name
Eaton XN-322 I/O module
Catalog Number
183181
Model Code
XN-322-4AIO-U2
EAN
4015081781140
Product Length/Depth
104.2 mm
Product Height
16.8 mm
Product Width
80.3 mm
Product Weight
0.055 kg
Certifications
UL File No.: E135462
IEC/EN 61000-6-2
CE
IEC/EN 61131-2
CULus
IEC/EN 61000-6-4

Features & Functions

Electric connection type
Plug-in connection
Features
Analog outputs configurable
Output, voltage
Input, voltage
Analog inputs configurable
Fieldbus connection over separate bus coupler possible
Input signal, configurable
Fitted with:
1 kHz, third-order low-pass input filter
Parameterizable Software input filter
Value representation
SIGNED16, mV, Voltage measurement
Voltage measurement
± 12 V DC, Common-mode range
Open wire monitoring.
-10 - 10 V DC, Measurement range
> 10 MΩ, Input resistance
The channels can also be used as potentiometer inputs.

General

Current consumption
55 mA (typ.), for +5 V power supply (internal), Power supply - Input
45 mA (typ.), for +24 V, Power supply - Input
Degree of protection
IP20
NEMA 1
Limit frequency
1 kHz (third-order low-pass filter)
Mounting method
Rail mounting possible
Number of channels
2, Analog Inputs
Overvoltage category
III
Pollution degree
3
Product category
XN-322 analog input and output module
Resolution
Type
  • Analog mixed module with 2 analog outputs -10 to +10 V (12 bit) and 4 analog inputs -10 to +10 V (16 bit) or potentiometer inputs (0-100%, reference output (+10 V/10 mA).
  • XN300 I/O slice module
Used with
XN300
XN-312-…
Voltage type
DC

Ambient conditions, mechanical

Height of fall (IEC/EN 60068-2-32) - max
1 m
Mounting position
Horizontal
Shock resistance
15 g, Mechanical, Half-sinusoidal shock 11 ms, 18 Impacts
Vibration resistance
5 - 8.4 / 8.4 -150 Hz, 3,5 mm / 1 g

Climatic environmental conditions

Air pressure
795 - 1080 hPa (operation)
Ambient operating temperature - min
0 °C
Ambient operating temperature - max
60 °C
Ambient storage temperature - min
-20 °C
Ambient storage temperature - max
85 °C
Climatic proofing
Dry heat to IEC 60068-2-2
Damp heat, constant, to IEC 60068-2-3
Environmental conditions
Condensation: prevent with appropriate measures
Relative humidity
0 - 95 % (non-condensing)

Electro magnetic compatibility

Air discharge
8 kV
Burst impulse
1 kV, Signal cable
2 kV, Supply cable
Contact discharge
4 kV
Electromagnetic fields
1 V/m at 2 - 2.7 GHz (according to IEC EN 61000-4-3)
10 V/m at 0.08 - 1.0 GHz (according to IEC EN 61000-4-3)
3 V/m at 1.4 - 2 GHz (according to IEC EN 61000-4-3)
Emitted interference
47 dB (at 230 - 1000 MHz, Class A, radiated, high frequency)
40 dB (at 30 - 230 MHz, Class A, radiated, high frequency)
Radiated RFI
10 V
Surge rating
1 kV, Signal cable, unbalanced, EMC
0.5/0.5 kV, Supply cable, balanced/unbalanced), EMC
Voltage dips
Voltage dips: 10 ms/Voltage fluctuations: Yes

Terminal capacities

Terminal capacity
0.25 - 1.5 mm², with ferrules without plastic collar according to DIN 46228-1 (ferrules crimped gas-tight)
0.2 - 1.5 mm², flexible without ferrule, H07V-K
24 - 16 AWG
0.2 - 1.5 mm², solid, H07V-U
0.25 - 0.75 mm², with ferrules with plastic collar according to DIN 46228-1 (ferrules crimped gas-tight)
Gauge pin
A1 (according to IEC/EN 60947-1)
Stripping length (main cable)
10 mm
Insulating material group
I

Electrical rating

Rated control supply voltage
10 V (Sensor/transmitter supply)
Rated operational voltage
160 V (terminations)
Short-circuit current
30 mA, per channel, Analog outputs
Short-circuit protection
Yes, Short-circuit strength, Analog outputs
Supply voltage at AC, 50 Hz - min
0 VAC
Supply voltage at AC, 50 Hz - max
0 VAC
Supply voltage at DC - min
18 VDC
Supply voltage at DC - max
30 VDC

Communication

Connection type
2 conductors, Voltage measurement
Push-in spring-cage terminal (plug-in connection), Connection design in TOP direction
2 conductors, Analog outputs, Output voltage
Protocol
Other bus systems

Input/Output

Accuracy
± 0.5 % of full scale, Analog outputs
± 0.3 % of full scale, Voltage measurement
Capacitive load
0.1 µF, Analog outputs
Input
2 Analog inputs (±10 V, Uref)
Input voltage
Max. 14 V DC
Load current
Not specified by plug manufacturer
Measured variables
Voltage or potentiometer
Number of inputs (analog)
2
Number of outputs (analog)
2
Output
2 Analog Outputs (±10 V)
Output voltage
-10 - 10 V DC (analog outputs)
Refresh time
1 ms (analog inputs, all channels)
Resistive load
> 5000 Ω, analog outputs
Value refresh time/cycle time
Min. 1 / 1 ms (per channel / all channels), Analog Inputs

Safety

Explosion safety category for dust
None
Explosion safety category for gas
None
Potential isolation
Analog inputs: no
Sensor/transmitter supply: no

Design verification

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
1.018 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
1.952 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 183181 Commande industrielle API (EC001596)
Caractéristique Valeur
Tension d'alimentation CA 50 Hz (EF007532) 0 V
Tension d'alimentation CA 60 Hz (EF007533) 0 V
Tension d'alimentation CC (EF007534) 18 V
Type de tension d'alimentation (EF002991) CC
Puissance absorbée (EF000346) 1.2 W
Entrée, courant (EF003204) Non
Entrée, tension (EF003205) Oui
Entrée, résistance (EF003206) Non
Entrée, thermomètre à résistance (EF003207) Non
Entrée, thermo-élément (EF003208) Non
Signal d'entrée configurable (EF003209) Oui
Résolution des entrées analogiques (EF003575) 16 Bit
Sortie, courant (EF003212) Non
Sortie, tension (EF003213) Oui
Signal de sortie configurable (EF003214) Non
Résolution des sorties analogiques (EF003577) 12 Bit
Nombre d'entrées analogiques (EF001994) 2
Nombre d'entrées numériques (EF001995) 2
Entrées analogiques configurables (EF008518) Oui
Sorties analogiques configurables (EF008519) Oui
Nombre d'interfaces matérielles Industrial Ethernet (EF003020) 0
Nombre d'interfaces matérielles PROFINET (EF006932) 0
Nombre d'interfaces matérielles en série RS-232 (EF003021) 0
Nombre d'interfaces matérielles en série RS-422 (EF003022) 0
Nombre d'interfaces matérielles en série RS-485 (EF003023) 0
Nombre d'interfaces matérielles en série TTY (EF003024) 0
Nombre d'interfaces matérielles parallèles (EF003026) 0
Nombre d'interfaces matérielles Wireless (EF006933) 0
Nombre d'interfaces matérielles USB (EF003025) 0
Nombre d'autres interfaces matérielles (EF003027) 1
supporte le protocole pour EtherCAT (EF017564) Non
Protocole pris en charge pour TCP/IP (EF003050) Non
Protocole pris en charge pour PROFIBUS (EF003052) Non
Protocole pris en charge pour CAN (EF003053) Non
Protocole pris en charge pour INTERBUS (EF003054) Non
Protocole pris en charge pour ASI (EF003051) Non
Protocole pris en charge pour KNX (EF003055) Non
Protocole pris en charge pour Modbus (EF003057) Non
Protocole pris en charge pour Data-Highway (EF003058) Non
Protocole pris en charge pour DeviceNet (EF003059) Non
Protocole pris en charge pour SUCONET (EF003060) Non
Protocole pris en charge pour LON (EF003017) Non
Protocole pris en charge pour PROFINET IO (EF007525) Non
Protocole pris en charge pour PROFINET CBA (EF007524) Non
Protocole pris en charge pour SERCOS (EF006657) Non
Protocole pris en charge pour Foundation Fieldbus (EF007522) Non
Protocole pris en charge pour EtherNet/IP (EF007521) Non
Protocole pris en charge pour AS-Interface Safety at Work (EF007519) Non
Protocole pris en charge pour DeviceNet Safety (EF007520) Non
Protocole pris en charge pour INTERBUS-Safety (EF006662) Non
Protocole pris en charge pour PROFIsafe (EF007526) Non
Protocole pris en charge pour SafetyBUS p (EF007527) Non
Protocole pris en charge pour autres systèmes de bus (EF003062) Oui
Standard radio Bluetooth (EF007178) Non
Standard radio WLAN 802.11 (EF007179) Non
Standard radio GPRS (EF008523) Non
Standard radio GSM (EF008524) Non
Standard radio UMTS (EF008525) Non
Maître IO-Link (EF007298) Non
Composants système (EF004118) Oui
Classe de protection (IP) (EF005474) IP20
Classe de protection (NEMA) (EF011959) 1
Finition du raccordement électrique (EF003961) Fiche
Raccordement au bus de champ possible sur coupleur de bus séparé (EF004002) Oui
Montage possible sur barres profilées (EF003972) Oui
Montage mural/direct possible (EF007020) Non
Encastrement frontal possible (EF007016) Non
Montage sur rack possible (EF007018) Non
Adapté aux fonctions de sécurité (EF001597) Non
SIL conformément à IEC 61508 (EF009889) Sans
Niveau de performance selon EN ISO 13849-1 (EF007399) Sans
Matériel associé (Ex ia) (EF004141) Non
Matériel associé (Ex ib) (EF004142) Non
Catégorie de protection contre les explosions pour le gaz (EF003997) Sans
Catégorie de protection contre les explosions pour la poussière (EF003998) Sans
certifié pour zone à risque UL classe I (EF017622) Non
certifié pour zone à risque UL classe II (EF017625) Non
certifié pour zone à risque UL classe III (EF017627) Non
certifié pour zone à risque UL division 1 (EF017628) Non
certifié pour zone à risque UL division 2 (EF017629) Non
certifié pour zone à risque UL groupe A (acétylène) (EF017632) Non
certifié pour zone à risque UL groupe B (hydrogène) (EF017633) Non
certifié pour zone à risque UL groupe C (éthylène) (EF017635) Non
certifié pour zone à risque UL groupe D (propane) (EF017636) Non
certifié pour zone à risque UL groupe E (poussière de métal) (EF017637) Non
certifié pour zone à risque UL groupe F (poussière carbonée) (EF017638) Non
certifié pour zone à risque UL groupe G (poussière non conductrice) (EF017639) Non
Largeur (EF000008) 80.3 mm
Hauteur (EF000040) 16.8 mm
Profondeur (EF000049) 104.2 mm

Datasheet - PDF

Commentaires: (0)

Aucun commentaire sur le produit encore.

Écrire commentaire
Sous forme de peau
Score:
Nom:
Email:
Titre:
Commentaire:
  Captcha
  Écrire commentaire

Toutes les évaluations que nous recevons des articles que nous proposons sont réels et vérifiés. Un petit geste, mais très précieux. Je vous remercie pour cette minute que vous passez à nous laisser votre avis et note sur les produits, car il nous aide à continuer à améliorer et à offrir encore plus la qualité de service.