Élément fonctionnel bouton-poussoir lumineux, SmartWire-DT, 1W, LED, bleu, fixation par l'avant
M22-SWD-K11LED-B
Eaton Moeller® series M22 Function element, for combination with RMQ-Titan operating elements M22-..., 1 changeover contact, Front fixing, blue
Elément de fonction, Fixation : Fixation frontale, Connexion à SmartWire-DT : oui

Catégories:

  • Appareillage industriel basse tension > Bloc de contact auxiliaire
  • EATON - MOELLER > Moyens de contrôle et de signalisation

Produit neuf dans son emballage d'origine avec toutes les garanties et les certifications émises par EATON - MOELLER

  • En savoir plus
  • ETIM
  • PDF
  • Commentaires
Garantie, réparation et dévolution.

Prix unitaire: 23,89 €

Ce prix est par unité et montre la valeur nette (excluant les taxes indirectes le cas échéant).

Calculer le prix par quantité

QuantitéPrix

Délai standard: 5 jours.

  • Ces délais sont estimatifs et peuvent varier une fois la commande de l'article traitée.

DERNIÈRE CONSULTÉS

EN SAVOIR PLUS

Spécifications générales

Product Name
Eaton Moeller® series M22 Function element
Catalog Number
115973
Model Code
M22-SWD-K11LED-B
EAN
4015081157136
Product Length/Depth
45 mm
Product Height
42 mm
Product Width
10 mm
Product Weight
0.009 kg
Certifications
UL File No.: E29184
CSA Class No.: 3211-07
EN 50178
UL
UL Category Control No.: NKCR
CSA File No.: 2324643
CSA
IEC/EN 61131-2
BV
LRS

Features & Functions

Electric connection type
Flat plug-in connection
Functions
For combination with RMQ-Titan operating elements M22-...
Diagnosis function

General

Degree of protection
IP20
Model
Top mounting
Model
Top mounting
Mounting method
Front fastening
Overvoltage category
Not applicable
Pollution degree
2

Ambient conditions, mechanical

Constant acceleration
1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations
Constant amplitude
3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations
Drop and topple
50 mm Drop height, Drop to IEC/EN 60068-2-31
Height of fall (IEC/EN 60068-2-32) - max
0.3 m
Mounting position
As required
Shock resistance
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts

Climatic environmental conditions

Ambient operating temperature - min
-30 °C
Ambient operating temperature - max
70 °C
Ambient storage temperature - min
40 °C
Ambient storage temperature - max
80 °C
Environmental conditions
Condensation: prevent with appropriate measures
Relative humidity
9 - 95 % (non-condensing, IEC/EN 60068-2-30)

Electro magnetic compatibility

Air discharge
8 kV, according to IEC 61131-2, level 3, ESD
Burst impulse
1 kV, SmartWire-DT cable, according to IEC/EN 61131-2, Level 3
2 kV, Supply cable, according to IEC/EN 61131-2, Level 3
Contact discharge
4 kV, according to IEC/EN 61131-2, Level 2, ESD
Electromagnetic fields
3 V/m at 1.4 - 2 GHz (according to IEC/EN 61131-2:2008)
10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008)
1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008)
Radiated RFI
10 V (IEC/EN 61131-2:2008, Level 3)
Radio interference class
Class A (EN 55011)

Electrical rating

Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V
0 A

Communication

Addressing
Address set automatically
Connection
SmartWire-DT plug connector SWD4-8SF2-5
Connection to SmartWire-DT
Yes
Connection type
Front fixing
SWD: Plug, 8-pole
LED indicator
Status indication of SmartWire-DT network: Green LED
Status indication of Switching state: Yellow LED
Station
SmartWire-DT slave, SmartWire-DT network

Contacts

Number of contacts (change-over contacts)
1
Number of contacts (normally closed contacts)
1

Design verification

Heat dissipation capacity Pdiss
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0.3 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 115973 Appareillage industriel basse tension (EC000041)

Nom de la caractéristiqueNombre de contacts en tant qu'inverseurs (EF008257)
Valeur de la caractéristique1
Nom de la caractéristiqueNombre de contacts en tant que contacts à fermeture (EF008256)
Valeur de la caractéristique1
Nom de la caractéristiqueNombre de contacts en tant que contacts à ouverture (EF008255)
Valeur de la caractéristique1
Nom de la caractéristiqueNombre d'interrupteurs de signal d'erreur (EF007613)
Valeur de la caractéristique0
Nom de la caractéristiqueCourant de fonctionnement nominal CA-15, 230 V (EF001385)
Valeur de la caractéristique0 A
Nom de la caractéristiqueFinition du raccordement électrique (EF003961)
Valeur de la caractéristiqueRaccordement par fiche plate
Nom de la caractéristiqueModèle (EF000010)
Valeur de la caractéristiqueRelevable
Nom de la caractéristiqueType de montage (EF000003)
Valeur de la caractéristiqueFixation frontale
Nom de la caractéristiqueDouille (EF000048)
Valeur de la caractéristiqueLED non interchangeable

Derniers commentaires de nos clients

Toutes les évaluations que nous recevons des articles que nous proposons sont réels et vérifiés. Un petit geste, mais très précieux. Je vous remercie pour cette minute que vous passez à nous laisser votre avis et note sur les produits, car il nous aide à continuer à améliorer et à offrir encore plus la qualité de service.