HLR50/1H(DC)230V 360052 EATON ELECTRIC Relais à semi-conducteurs Hockey Puck, 50A, 230V

HLR50/1H(DC)230V

360052

EATON-MOELLER

Relais à semi-conducteurs Hockey Puck, 50A, 230V

Solid-state relay, Hockey Puck, 1-phase, 50 A, 24 - 265 V, DC

Plus de détails


Démarreurs progressifs standard

* Produit neuf dans son emballage d'origine avec toutes les garanties et les certifications émises par EATON-MOELLER

Prix total: $29.88
Prix unitaire: $29.88

*Ce prix est par unité et montre la valeur nette (excluant les taxes indirectes le cas échéant) .

Si notre prix n'est pas le meilleur, demandez-nous un devis. Demander un devis

Produits consultés


En savoir plus



Solid-state relay, Hockey Puck, 1-phase, 50 A, 24 - 265 V, DC
Solid-state relay, 1-phase, 50 A, 24 - 265 V, DC, IP20, Screw connection, Switching at zero-crossing, CE, CSA Certified, UL 508, EAC, CCC

General specifications
Product name
Eaton Moeller series HLR solid state relay
Part no.
HLR50/1H(DC)230V
EAN
4015081998197
Product Length/Depth
28.8 millimetre
Product height
58.2 millimetre
Product width
44.8 millimetre
Product weight
0.06 kilogram
Compliances
RoHS Compliant
CE Marked
Certifications
EAC
UL 508
CE
CCC
UL-File No.: E338590
CSA-File No.: 603498
Product Tradename
HLR
Product Type
Solid-state relay
Product Sub Type
None
General information
Degree of protection
IP20
Frequency rating
45 Hz - 65 Hz
Mounting position
Mount device in specified orientation and do not obstruct the heatsink
Number of phases
1
Number of pilot lights
1
Overvoltage category
III
Pollution degree
2
Rated impulse withstand voltage (Uimp)
6 kV (1.2/50 μs)
Series
HLR
Shock resistance
15/11 g/ms (according to EN 50155, EN 61373)
Type
Solid-state relay
Vibration resistance
2 g/axis (2-100 Hz, IEC 60068-2-6, EN 50155, EN 61373)
Voltage type
DC
Features & Functions
Functions
Switching at zero-crossing
Electrical connection type for auxiliary- and control-current circuit
Screw connection
Electrical connection type of main circuit
Screw connection
Climatic environmental conditions
Altitude
9
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
100 °C
Climatic proofing
95% relative humidity non-condensing at 40°C
Operating temperature - min
-40 °C
Operating temperature - max
80 °C
Electro magnetic compatibility
Air discharge
8 kV (according to IEC/EN 61000-4-2)
Burst Impulse
Main: 2 kV, 5 kHz PC 1 (according to IEC/EN 61000-4-4)
Control: 1 kV, 5 kHz PC 1 (according to IEC/EN 61000-4-4)
Contact discharge
4 kV (according to IEC/EN 61000-4-2)
Electromagnetic fields
10 V/m, 80 - 1000 MHz and 1.4 - 2.0 GHz, PC 1
3 V/m, 2.0 - 2.7 GHz, PC 1
Immunity to line-conducted interference
10 V/m, 0.15 - 80 MHz, PC 1 (according to IEC/EN 61000-4-6)
Radio interference class
Class A
Terminal capacities
Terminal capacity (flexible with ferrule)
Main: 1 x 1-4 mm², 2 x 1-4 mm²
Control: 1 x 0.5-2.5 mm², 2 x 0.5-2.5 mm²
Terminal capacity (solid)
Main: 1 x 2.5-6 mm², 2 x 2.5-6 mm²
Control: 1 x 0.5-2.5 mm², 2 x 0.5-2.5 mm²
Terminal capacity (solid/stranded AWG)
Main: 1 x 14-10, 2 x 14-10
Control: 1 x 18-12, 2 x 18-12
Terminal capacity (stranded)
Main: 1 x 2.5-6 mm², 2 x 2.5-6 mm²
Control: 1 x 0.5-2.5 mm², 2 x 0.5-2.5 mm²
Tightening torque
Main: 2.4 Nm (21.2 lb-in)
Control: 0.5 Nm (4.4 lb-in)
Screwdriver size
Main: Pozidriv 2
Control: Pozidriv 1
Electrical rating
Operating voltage - max.
265 V
Operating voltage - min.
24 V
Rated operational current (Ie) at AC-1
0 A
Rated operational current (Ie) at AC-3
0 A
Rated operational current (Ie) at AC-51
50 A
Rated operational current (Ie) at AC-53A
15 A
Rated operational current (Ie) at AC-53B
0 A
Rated operational voltage (Ue) at AC - min
24 V
Rated operational voltage (Ue) at AC - max
265 V
Control circuit
Delay time
1/2 period
Drop-out time
< 1/2 period
Drop-out voltage
1.2 V DC
Input current
< 12 mA
Pick-up voltage
2.5 V DC
Rated control supply voltage (Us) at AC, 50 Hz - min
0 V
Rated control supply voltage (Us) at AC, 50 Hz - max
0 V
Rated control supply voltage (Us) at AC, 60 Hz - min
0 V
Rated control supply voltage (Us) at AC, 60 Hz - max
0 V
Rated control supply voltage (Us) at DC - min
3 V
Rated control supply voltage (Us) at DC - max
32 V
Design verification
Equipment heat dissipation, current-dependent Pvid
56 W
Heat dissipation per pole, current-dependent Pvid
56 W
Rated operational current for specified heat dissipation (In)
50 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Please enquire
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 9.0

Relays (EG000019) / Relais statique (EC002055)
Electricité, Electronique, Automatisation et Commande / Technique de commutation basse tension / Contacteur (BT) / Relais statique (ecl@ss13-27-37-10-14 [ACN970016])
Type of electric connection
Screw connection
Complete with socket
No
With detachable clamps
No
Modular version
No
With LED indication
Yes
Rated control supply voltage AC 50 Hz
0 - 0 V
Rated control supply voltage AC 60 Hz
0 - 0 V
Rated control supply voltage DC
3 - 32 V
Voltage type for actuating
DC
Number of phases
1
Model
Other
Type of switch function
Switching at zero-crossing
Yes
Voltage type (operating voltage)
AC
Operating voltage AC 50 Hz
42 - 230 V
Operating voltage AC 60 Hz
42 - 230 V
Operating voltage DC
0 - 0 V
Rated operation current Ie at AC-1
0 A
Rated operation current Ie at AC-3
0 A
Rated operation current Ie at AC-51
50 A
Rated operation current Ie at AC-53a
15 A
Rated operation current Ie at AC-53b
0 A
Degree of protection (IP)
IP20
Relay technology category according to IEC 61810-7
Width
44.8 mm
Height
58.2 mm
Depth
28.8 mm

Datasheet - PDF

Commentaires: (0)

Aucun commentaire sur le produit encore.

Écrire commentaire
Sous forme de peau
Score:
Nom:
Email:
Titre:
Commentaire:
  Captcha
  Écrire commentaire

Toutes les évaluations que nous recevons des articles que nous proposons sont réels et vérifiés. Un petit geste, mais très précieux. Je vous remercie pour cette minute que vous passez à nous laisser votre avis et note sur les produits, car il nous aide à continuer à améliorer et à offrir encore plus la qualité de service.