ANUNCIAR
DC1-S2011FB-A20CE1 186094 Y7-186094 EATON ELECTRIC Variable frequency drives, 1-/single-phase 230 V, 10.5 A,.. Agrandir l'image
Les images sont à titre illustratif. Svp, révisez la fiche technique.

DC1-S2011FB-A20CE1 186094 Y7-186094 EATON ELECTRIC Variable frequency drives, 1-/single-phase 230 V, 10.5 A,..

DC1-S2011FB-A20CE1

186094

Y7-186094

EATON-MOELLER

Variable frequency drives, 1-/single-phase 230 V, 10.5 A, 1.1 kW, EMC Filters, braking transistor

DC1-S2011FB-A20CE1

Eaton DC1 Variable frequency drive, 230 V AC, 1-phase, 10.5 A, 1.1 kW, IP20/NEMA 0, Radio interference suppression filter, Brake chopper, FS2 DC1-S2011FB-A20CE1

Variateur de fréquence, référence de groupe de pièces (par ex. DIL) : DC1, Tension nominale de fonctionnement : Ue = 230 V AC, 1 phase, 240 V AC, monophasé, Tension de sortie avec Ve : U2 = 230 V AC, monophasé, 240 V AC, monophasé, Tension secteur (50/60Hz) : ULN = 200 (-10%) - 240 (+10%) V, Courant nominal de fonctionnement à 150% de surcharge : Ie = 10,5 A, Remarque : Courant nominal de fonctionnement à une fréquence de fonctionnement de 16 kHz et une température de l’air ambiant de +50 °C, Remarque : Cycle de surcharge pendant 60 s toutes les 600 s, Puissance nominale du moteur Remarque : Pour les moteurs à courant alternatif avec ventilation interne et externe avec 50/60 Hz sans condensateur de démarrage supplémentaire, Cycle de surcharge pendant 60 s toutes les 600 s, à 230 V, 50 Hz, Puissance nominale du moteur 150 % Surcharge : P = 1,1 kW, 150 % Surcharge : IM = 10,5 A, Puissance nominale du moteur Remarque : à 220 - 240 V, 60 Hz, Puissance nominale du moteur 150 % Surcharge : P = 1,5 CV, Puissance nominale du moteur 150 % Surcharge : IM = 9,6 A, Degré de protection : IP20/NEMA 0, Interface/bus de terrain (intégré) : OP-Bus (RS485)/Modbus RTU, CANopen®, Connexion au bus de terrain (en option) : SmartWire-DT, Équipé de : Filtre anti-interférences radio, Hachoir de frein, Ensemble d’affichage à 7 chiffres, Taille du cadre : FS2, Normes : Spécification des exigences générales : IEC/EN 61800-2, Exigences CEM : IEC/EN 61800-3 , Exigences de sécurité : IEC/EN 61800-5-1

Plus de détails


Appareillage industriel basse tension > Convertisseur de fréquences inférieur à 1kV

Convertisseurs de fréquence Power XL

Produit neuf dans son emballage d'origine avec toutes les garanties et les certifications émises par EATON-MOELLER

Prix total: $580.68
Prix unitaire: $580.68
Ce prix est par unité et montre la valeur nette (excluant les taxes indirectes le cas échéant) .

Si notre prix n'est pas le meilleur, demandez-nous un devis. Demander un devis

Related products

Les plus vendus

En savoir plus



Spécifications générales

Product Name
Eaton DC1 Variable frequency drive
Catalog Number
186094
Model Code
DC1-S2011FB-A20CE1
EAN
4015081815951
Product Length/Depth
152 mm
Product Height
231 mm
Product Width
107 mm
Product Weight
1.2 kg
Certifications
Certified by UL for use in Canada
IEC/EN 61800-3
IEC/EN61800-5
Safety requirements: IEC/EN 61800-5-1
UL File No.: E172143
CE
CUL
IEC/EN61800-3
UL 508C
UL Category Control No.: NMMS, NMMS7
UL report applies to both US and Canada
CSA-C22.2 No. 14
EAC
Specification for general requirements: IEC/EN 61800-2
RCM
UL
RoHS, ISO 9001
UkrSEPRO
Catalog Notes
Environmental class: 3C2, 3S2

Features & Functions

Features
Parameterization: drivesConnect
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: Keypad
Fitted with:
Control unit
Breaking resistance
IGBT inverter
Radio interference suppression filter
PC connection
Brake chopper
7-digital display assembly
Internal DC link
Additional PCB protection
Functions
4-quadrant operation possible

General

Cable length
C1 ≤ 1 m, Radio interference level, maximum motor cable length
C3 ≤ 25 m, Radio interference level, maximum motor cable length
150 m, unscreened, maximum permissible, Motor feeder
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
C2 ≤ 5 m, Radio interference level, maximum motor cable length
100 m, screened, maximum permissible, Motor feeder
200 m, screened, with motor choke, maximum permissible, Motor feeder
Communication interface
OP-Bus (RS485), built in
CANopen®, built in
SmartWire-DT, optional
Modbus RTU, built in
Connection to SmartWire-DT
In conjunction with DX-NET-SWD3 SmartWire DT module
Yes
Degree of protection
IP20
NEMA 0
Electromagnetic compatibility
1st and 2nd environments (according to EN 61800-3)
Frame size
FS2
Mounting position
Vertical
Product category
Variable frequency drives
Protection
Finger and back-of-hand proof, Protection against direct contact (BGV A3, VBG4)
Protocol
Other bus systems
EtherNet/IP
CAN
MODBUS
Radio interference class
C1: for conducted emissions only
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Suitable for
Branch circuits, (UL/CSA)

Climatic environmental conditions

Altitude
Above 1000 m with 1 % derating per 100 m
Max. 4000 m
Ambient operating temperature - min
-10 °C
Ambient operating temperature - max
50 °C
Ambient operating temperature at 150% overload - min
-10 °C
Ambient operating temperature at 150% overload - max
50 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
60 °C
Climatic proofing
< 95 average relative humidity (RH), no condensation, no corrosion

Main circuit

Efficiency
96 % (η)
Input current ILN at 150% overload
19.2 A
Leakage current at ground IPE - max
2.49 mA
Mains switch-on frequency
Maximum of one time every 30 seconds
Mains voltage - min
200 V
Mains voltage - max
240 V
Operating mode
U/f control
Speed control with slip compensation
BLDC motors
PM motors
Sensorless vector control (SLV)
Synchronous reluctance motors
Output frequency - min
0 Hz
Output frequency - max
500 Hz
Output voltage (U2)
240 V AC, single-phase
230 V AC, single-phase
Overload current IL at 150% overload
15.75 A
Rated control supply voltage
10 V DC (Us, max. 10 mA)
Rated frequency - min
48 Hz
Rated frequency - max
62 Hz
Rated operational current (Ie)
10.5 A at 150% overload (at an operating frequency of 16 kHz and an ambient air temperature of +50 °C)
Rated operational voltage
240 V AC, 1-phase
230 V AC, 1-phase
Resolution
0.1 Hz (Frequency resolution, setpoint value)
Short-circuit protection rating
25 A, UL (Class CC or J), Safety device (fuse or miniature circuit-breaker), Power Wiring
Starting current - max
175 %, IH, max. starting current (High Overload), For 2.5 seconds every 600 seconds, Power section
Supply frequency
50/60 Hz
Switching frequency
8 kHz, 4 - 32 kHz adjustable (audible), fPWM, Power section, Main circuit
System configuration type
AC supply systems with earthed center point
Voltage rating - max
240 V

Motor rating

Assigned motor current IM at 220 - 240 V, 60 Hz, 150% overload
9.6 A
Assigned motor current IM at 230 V, 50 Hz, 150% overload
10.5 A
Assigned motor power at 230/240 V, 60 Hz, 1-phase
1.5 HP

Apparent power

Apparent power at 230 V
2.42 kVA
Apparent power at 240 V
2.52 kVA

Braking function

Braking resistance
100 Ω
Braking torque
Max. 100 % of rated operational current Ie, variable, DC - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit
Switch-on threshold for the braking transistor
390 VDC

Control circuit

Number of inputs (analog)
2
Number of inputs (digital)
4
Number of outputs (analog)
1
Number of outputs (digital)
1
Number of relay outputs
1 (parameterizable, N/O, 6 A (250 V, AC-1) / 5 A (30 V, DC-1))

Design verification

Equipment heat dissipation, current-dependent Pvid
44 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
10.5 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 186094 Appareillage industriel basse tension (EC001857)
Caractéristique Valeur
Tension du secteur (EF006780) 200 V
Fréquence du secteur (EF006783) 50/60 Hz
Nombre de phases d'entrée (EF007117) 1
Nombre de phases de sortie (EF006998) 1
Fréquence de sortie max. (EF007350) 500 Hz
Tension de sortie max. (EF009560) 250 V
Courant de sortie nominal I2N (EF009561) 11 A
Puissance utile max. en charge quadratique sous tension de sortie assignée (EF007366) 1.1 kW
Puissance utile max. en charge linéaire sous tension de sortie assignée (EF007364) 1.1 kW
Puissance absorbée (EF000346) 44 W
Tolérance relative de fréquence du réseau symétrique (EF007454) 10 %
Tolérance relative de tension du réseau symétrique (EF007453) 10 %
Nombre d'entrées numériques (EF001995) 1
Nombre d'entrées analogiques (EF001994) 2
Nombre de sorties numériques (EF001993) 1
Nombre d'entrées numériques (EF001992) 4
Avec élément de commande (EF001538) Oui
Utilisation autorisée en zone industrielle (EF007294) Oui
Utilisation autorisée en zone résidentielle et commerciale (EF007295) Oui
Protocole pris en charge pour TCP/IP (EF003050) Non
Protocole pris en charge pour PROFIBUS (EF003052) Non
Protocole pris en charge pour CAN (EF003053) Oui
Protocole pris en charge pour INTERBUS (EF003054) Non
Protocole pris en charge pour ASI (EF003051) Non
Protocole pris en charge pour KNX (EF003055) Non
Protocole pris en charge pour Modbus (EF003057) Oui
Protocole pris en charge pour Data-Highway (EF003058) Non
Protocole pris en charge pour DeviceNet (EF003059) Non
Protocole pris en charge pour SUCONET (EF003060) Non
Protocole pris en charge pour LON (EF003017) Non
Protocole pris en charge pour PROFINET IO (EF007525) Non
Protocole pris en charge pour PROFINET CBA (EF007524) Non
Protocole pris en charge pour SERCOS (EF006657) Non
Protocole pris en charge pour Foundation Fieldbus (EF007522) Non
Protocole pris en charge pour EtherNet/IP (EF007521) Oui
Protocole pris en charge pour AS-Interface Safety at Work (EF007519) Non
Protocole pris en charge pour DeviceNet Safety (EF007520) Non
Protocole pris en charge pour INTERBUS-Safety (EF006662) Non
Protocole pris en charge pour PROFIsafe (EF007526) Non
Protocole pris en charge pour SafetyBUS p (EF007527) Non
Protocole pris en charge pour BACnet (EF011944) Non
Protocole pris en charge pour autres systèmes de bus (EF003062) Oui
Nombre d'interfaces matérielles Industrial Ethernet (EF003020) 0
Nombre d'interfaces matérielles PROFINET (EF006932) 0
Nombre d'interfaces matérielles en série RS-232 (EF003021) 0
Nombre d'interfaces matérielles en série RS-422 (EF003022) 0
Nombre d'interfaces matérielles en série RS-485 (EF003023) 1
Nombre d'interfaces matérielles en série TTY (EF003024) 0
Nombre d'interfaces matérielles USB (EF003025) 0
Nombre d'interfaces matérielles parallèles (EF003026) 0
Nombre d'autres interfaces matérielles (EF003027) 0
Avec interface optique (EF003028) Non
Avec raccordement PC (EF006107) Oui
Hacheur de freinage intégré (EF007293) Oui
Fonctionnement possible à quatre quadrants (EF006803) Oui
Type de convertisseur (EF006978) Convertisseur U
Classe de protection (IP) (EF005474) IP20
Classe de protection (NEMA) (EF011959) Autre
Hauteur (EF000040) 231 mm
Largeur (EF000008) 107 mm
Profondeur (EF000049) 152 mm

Datasheet - PDF

Commentaires: (0)

Aucun commentaire sur le produit encore.

Écrire commentaire
Sous forme de peau
Score:
Nom:
Email:
Titre:
Commentaire:
  Captcha
  Écrire commentaire

Toutes les évaluations que nous recevons des articles que nous proposons sont réels et vérifiés. Un petit geste, mais très précieux. Je vous remercie pour cette minute que vous passez à nous laisser votre avis et note sur les produits, car il nous aide à continuer à améliorer et à offrir encore plus la qualité de service.