Producto añadido correctamente a su carrito de la compra
RAMO5-D204A32-412RS1
199078
Y7-199078
EATON-MOELLER
1
Arrancador DOL, 6.6 A, 400 V, 50 Hz, 0,09 - 3 kW, Tensión Para el freno
Eaton Moeller® series Rapid Link - DOL starter, 6.6 A, Sensor input 2, 400/480 V AC, AS-Interface®, S-7.A.E. for 62 modules, HAN Q4/2, with manual override switch
Arrancador DOL, 6.6 A, entrada de sensor 2, 400/480 V AC, AS-Interface®, S-7.A.E. para 62 módulos, HAN Q4/2, con interruptor de anulación manual
Componentes industriales de baja tensión > Combinación de arrancador de motor/motor de arranque
Arrancadores Rapid Link
Producto nuevo en su embalaje original con todas las garantías y certificaciones de EATON-MOELLER
Gracias por su interés en nuestros productos, esperamos que el plazo indicado sea conveniente para usted.
Durante la tramitación del pedido podrá seleccionar el tipo de envío que mejor se adapte a sus necesidades: Aéreo Express 24Hrs, Terrestre Standard 48/72Hrs, etc.
| Product Name | Eaton Rapid Link DOL starter |
| Catalog Number | 199078 |
| EAN | 4015081971367 |
| Product Length/Depth | 120 mm |
| Product Height | 270 mm |
| Product Width | 220 mm |
| Product Weight | 1.8 kg |
| Certifications | RoHS UL 60947-4-2 IEC/EN 60947-4-2 CCC CE UL approval |
| Catalog Notes | Assigned motor rating: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm at 50 Hz or 1800 min at 60 Hz |
| Model Code | RAMO5-D204A32-412RS1 |
| Features | Parameterization: drivesConnect mobile (App) Parameterization: Fieldbus Diagnostics and reset on device and via AS-Interface Parameterization: Keypad Parameterization: drivesConnect |
| Fitted with: | Key switch position AUTO Thermo-click Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation Key switch position HAND Manual override switch Thermistor monitoring PTC Electronic motor protection Key switch position OFF/RESET Short-circuit release |
| Functions | For actuation of motors with mechanical brake External reset possible Temperature compensated overload protection |
| Class | CLASS 10 A |
| Degree of protection | IP65 NEMA 12 |
| Electromagnetic compatibility | Class A |
| Lifespan, electrical | 10,000,000 Operations (at AC-3) |
| Lifespan, mechanical | 10,000,000 Operations (at AC-3) |
| Model | Direct starter |
| Overload release current setting - min | 0.3 A |
| Overload release current setting - max | 6.6 A |
| Overvoltage category | III |
| Product category | Motor starter |
| Product category | Motor starter |
| Protocol | AS-Interface profile cable: S-7.4 for 62 modules ASI |
| Rated impulse withstand voltage (Uimp) | 4000 V |
| System configuration type | AC voltage Phase-earthed AC supply systems are not permitted. Center-point earthed star network (TN-S network) |
| Type | DOL starter |
| Voltage type | DC |
| Mounting position | Vertical |
| Shock resistance | 15 g, Mechanical, According to IEC/EN 60068-2-27, 11 ms, Half-sinusoidal shock 11 ms, 1000 shocks per shaft |
| Vibration | Resistance: 6 Hz, Amplitude 0.15 mm Resistance: 10 - 150 Hz, Oscillation frequency Resistance: According to IEC/EN 60068-2-6 Resistance: 57 Hz, Amplitude transition frequency on acceleration |
| Altitude | Max. 2000 m Max. 1000 m Above 1000 m with 1 % performance reduction per 100 m |
| Ambient operating temperature - min | -10 °C |
| Ambient operating temperature - max | 55 °C |
| Ambient storage temperature - min | -40 °C |
| Ambient storage temperature - max | 70 °C |
| Climatic proofing | < 95 %, no condensation In accordance with IEC/EN 50178 |
| Current limitation | Adjustable, motor, main circuit 0.3 - 6.6 A, motor, main circuit |
| Input current | 6.6 A (at 150 % Overload) |
| Mains switch-on frequency | Maximum of one time every 60 seconds |
| Mains voltage tolerance | 380 - 480 V (-15 %/+10 %, at 50/60 Hz) |
| Off-delay | 20 - 35 ms |
| On-delay | 20 - 35 ms |
| Output frequency | 50/60 Hz |
| Overload cycle | AC-53a |
| Rated frequency - max | 63 Hz |
| Rated frequency - min | 47 Hz |
| Rated operational current (Ie) | 6.6 A |
| Rated operational current (Ie) at 150% overload | 6.6 A |
| Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V | 6.6 A |
| Rated operational power at 380/400 V, 50 Hz - max | 3 kW |
| Rated operational power at 380/400 V, 50 Hz - min | 0.09 kW |
| Rated operational power at AC-3, 380/400 V, 50 Hz | 3 kW |
| Rated operational voltage | 480 V AC, 3-phase 400 V AC, 3-phase |
| Supply frequency | 50/60 Hz, fLN, Main circuit |
| Assigned motor power at 460/480 V, 60 Hz, 3-phase | 3 HP |
| Braking current | ≤ 0.6 A (max. 6 A for 120 ms), Actuator for external motor brake |
| Braking voltage | 400/480 V AC -15 % / +10 %, Actuator for external motor brake |
| Rated conditional short-circuit current (Iq) | 10 kA |
| Short-circuit protection (external output circuits) | Type 1 coordination via the power bus' feeder unit, Main circuit |
| Rated control voltage (Uc) | 400/480 V AC (external brake 50/60 Hz) 24 V DC (-15 %/+20 %, external via AS-Interface® plug) |
| Connection | Connections pluggable in power section |
| Interfaces | Max. total power consumption from AS-Interface® power supply unit (30 V): 190 mA Specification: S-7.A.E. (AS-Interface®) Number of slave addresses: 62 (AS-Interface®) |
| Number of auxiliary contacts (normally closed contacts) | 0 |
| Number of auxiliary contacts (normally open contacts) | 0 |
| Cable length | 10 m, Radio interference level, maximum motor cable length |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| Característica | Valor |
|---|---|
| Tipo de arrancador de motor (EF009598) | Motor de arranque directo |
| Con liberación de cortocircuito (EF006691) | Sí |
| Voltaje nominal de suministro piloto piloto para CA 50 Hz (EF003978) | 0 V |
| Voltaje nominal de suministro piloto piloto para CA 60 Hz (EF003979) | 0 V |
| Voltaje nominal de suministro piloto de piloto para CC (EF003980) | 0 V |
| Tipo de tensión de accionamiento (EF008242) | CC |
| Potencia asignada de empleo con AC-3, 230 V, trifásica (EF009599) | 0 kW |
| Potencia de funcionamiento nominal en CA-3, 400 V (EF001364) | 3 kW |
| Potencia asignada, 460 V, 60 Hz, trifásica (EF009600) | 2.238 kW |
| Potencia asignada, 575 V, 60 Hz, trifásica (EF009601) | 0 kW |
| Corriente nominal de funcionamiento Ie (EF001443) | 6.6 A |
| Intensidad asignada de empleo con AC-3, 400 V (EF009602) | 6.6 A |
| Ajuste actual de liberación de sobrecarga (EF002336) | 0.3 A |
| Corriente condicional asignada de cortocircuito, tipo 1, 480 Y/277 V (EF009607) | 10000 A |
| Corriente condicional asignada de cortocircuito, tipo 1, 600 Y/347 V (EF009608) | 0 A |
| Corriente condicional asignada de cortocircuito, tipo 2, 230V (EF009606) | 0 A |
| Corriente condicional asignada de cortocircuito, tipo 2, 400V (EF009605) | 0 A |
| Consumo de energía (EF000346) | 8 W |
| Número de contactos auxiliares normalmente abiertos (EF001376) | 0 |
| Número de contactos auxiliares normalmente cerrados (EF001377) | 0 |
| Temperatura ambiente, límite superior sin restricciones (EF009603) | 55 °C |
| Protección contra sobrecargas, termocompensada (EF009604) | Sí |
| Clase de disparo (EF006668) | CLASE 10 A |
| Tipo de conexión del circuito de corriente principal (EF006819) | Conexión enchufable |
| Tipo de conexión eléctrica para circuitos auxiliares y de control (EF006979) | Conexión enchufable |
| Montaje en carril posible (EF003972) | No |
| Con transformador (EF000278) | No |
| Número de puestos de mando (EF001372) | 1 |
| Apto para parada de emergencia (EF001433) | No |
| Tipo de clasificación según IEC 60947-4-3 (EF012390) | Clase 1 |
| Número de luces indicadoras (EF001965) | 0 |
| Reinicio externo posible (EF003426) | Sí |
| Con fusible (EF006693) | No |
| Grado de protección (IP) (EF005474) | IP65 |
| Grado de protección (NEMA) (EF011959) | 12 |
| Soporta el protocolo TCP/IP (EF003050) | No |
| Soporta el protocolo PROFIBUS (EF003052) | No |
| Soporta el protocolo CAN (EF003053) | No |
| Soporta el protocolo INTERBUS (EF003054) | No |
| Soporta el protocolo ASI (EF003051) | Sí |
| Soporta el protocolo Modbus (EF003057) | No |
| Soporta el protocolo de autopista de datos (EF003058) | No |
| Soporta el protocolo DeviceNet (EF003059) | No |
| Soporta el protocolo SUCONET (EF003060) | No |
| Soporta el protocolo LON (EF003017) | No |
| Soporta el protocolo PROFINET IO (EF007525) | No |
| Soporta el protocolo PROFINET CBA (EF007524) | No |
| Soporta el protocolo SERCOS (EF006657) | No |
| Soporta el protocolo Foundation Fieldbus (EF007522) | No |
| Soporta el protocolo Ethernet/IP (EF007521) | No |
| Soporta el protocolo AS-Interface Safety at Work (EF007519) | No |
| Soporta el protocolo DeviceNet Safety (EF007520) | No |
| Soporta el protocolo de seguridad INTERBUS (EF006662) | No |
| Soporta el protocolo PROFIsafe (EF007526) | No |
| Soporta el protocolo SafetyBUS p (EF007527) | No |
| Soporta el protocolo para otros sistemas bus (EF003062) | No |
| Anchura (EF000008) | 220 mm |
| Altura (EF000040) | 270 mm |
| Profundidad (EF000049) | 120 mm |
| Título: | Tamaño: | Tipo: |
|---|---|---|
| PDF EATON STARTING CONTROLLING MOTORS EN.pdf | 37 Mbytes |
|
| PDF CATALOGUE EATON EN .pdf | 38 Mbytes |
|
Ningún comentario por el momento.
| Valoración: |
|
| Nombre: | |
| Email: | |
| Título: | |
| Opinión: | |
| ¿Recomienda la compra de este producto? | |
|
|
|
| Añadir comentario | |
Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.