ANUNCIAR
RAMO5-D201A31-512RS1 199068 Y7-199068 EATON ELECTRIC Arrancador DOL. 6.6 A. 400 V. 50 Hz. 0,09 3 kW. Tensión.. Ver más grande
Las imágenes son sólo a título ilustrativo. Por favor, revise la ficha técnica.

RAMO5-D201A31-512RS1 199068 Y7-199068 EATON ELECTRIC Arrancador DOL. 6.6 A. 400 V. 50 Hz. 0,09 3 kW. Tensión..

RAMO5-D201A31-512RS1

199068

Y7-199068

EATON-MOELLER

Arrancador DOL, 6.6 A, 400 V, 50 Hz, 0,09 - 3 kW, Tensión Para el freno

Eaton Moeller® series Rapid Link - DOL starter, 6.6 A, Sensor input 2, 180/207 V DC, AS-Interface®, S-7.4 for 31 modules, HAN Q5, with manual override switch

Arrancador DOL, 6,6 A, Entrada de sensor 2, 180/207 V CC, AS-Interface®, S-7.4 para 31 módulos, HAN Q5, con interruptor de anulación manual

Más detalles


Componentes industriales de baja tensión > Combinación de arrancador de motor/motor de arranque

Arrancadores Rapid Link

Producto nuevo en su embalaje original con todas las garantías y certificaciones de EATON-MOELLER

Precio total: $1,220.22
Precio unitario: $1,220.22
Este precio es por unidad y muestra el valor neto (no incluye impuestos indirectos si son aplicables).

Si nuestro precio no es el mejor solicítenos presupuesto Solicitar presupuesto

productos relacionados

Más vendidos

Más Información



Especificaciones generales

Product Name
Eaton Moeller® series Rapid Link DOL starter
Catalog Number
199068
EAN
4015081971268
Product Length/Depth
120 mm
Product Height
270 mm
Product Width
220 mm
Product Weight
1.8 kg
Certifications
RoHS
UL 60947-4-2
CE
UL approval
IEC/EN 60947-4-2
CCC
Catalog Notes
Assigned motor rating: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm at 50 Hz or 1800 min at 60 Hz
Model Code
RAMO5-D201A31-512RS1

Features & Functions

Features
Parameterization: Fieldbus
Parameterization: drivesConnect
Diagnostics and reset on device and via AS-Interface
Parameterization: drivesConnect mobile (App)
Parameterization: Keypad
Fitted with:
Thermistor monitoring PTC
Electronic motor protection
Thermo-click
Key switch position OFF/RESET
Key switch position HAND
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Key switch position AUTO
Manual override switch
Short-circuit release
Functions
For actuation of motors with mechanical brake
External reset possible
Temperature compensated overload protection

General

Class
CLASS 10 A
Degree of protection
NEMA 12
IP65
Electromagnetic compatibility
Class A
Lifespan, electrical
10,000,000 Operations (at AC-3)
Lifespan, mechanical
10,000,000 Operations (at AC-3)
Model
Direct starter
Overload release current setting - min
0.3 A
Overload release current setting - max
6.6 A
Overvoltage category
III
Product category
Motor starter
Protocol
AS-Interface profile cable: S-7.4 for 31 modules
ASI
Rated impulse withstand voltage (Uimp)
4000 V
System configuration type
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
AC voltage
Type
DOL starter
Voltage type
DC

Ambient conditions, mechanical

Mounting position
Vertical
Shock resistance
15 g, Mechanical, According to IEC/EN 60068-2-27, 11 ms, Half-sinusoidal shock 11 ms, 1000 shocks per shaft
Vibration
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: According to IEC/EN 60068-2-6

Climatic environmental conditions

Altitude
Above 1000 m with 1 % performance reduction per 100 m
Max. 2000 m
Max. 1000 m
Ambient operating temperature - min
-10 °C
Ambient operating temperature - max
55 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
70 °C
Climatic proofing
< 95 %, no condensation
In accordance with IEC/EN 50178

Main circuit

Current limitation
Adjustable, motor, main circuit
0.3 - 6.6 A, motor, main circuit
Input current
6.6 A (at 150 % Overload)
Mains switch-on frequency
Maximum of one time every 60 seconds
Mains voltage tolerance
380 - 480 V (-15 %/+10 %, at 50/60 Hz)
Off-delay
20 - 35 ms
On-delay
20 - 35 ms
Output frequency
50/60 Hz
Overload cycle
AC-53a
Rated frequency - min
47 Hz
Rated frequency - max
63 Hz
Rated operational current (Ie)
6.6 A
Rated operational current (Ie) at 150% overload
6.6 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
6.6 A
Rated operational power at 380/400 V, 50 Hz - min
0.09 kW
Rated operational power at 380/400 V, 50 Hz - max
3 kW
Rated operational power at AC-3, 220/230 V, 50 Hz
0 kW
Rated operational power at AC-3, 380/400 V, 50 Hz
3 kW
Rated operational voltage
400 V AC, 3-phase
480 V AC, 3-phase
Supply frequency
50/60 Hz, fLN, Main circuit
System configuration type
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
AC voltage

Motor rating

Assigned motor power at 460/480 V, 60 Hz, 3-phase
3 HP

Braking function

Braking current
≤ 0.6 A (max. 6 A for 120 ms), Actuator for external motor brake
Braking voltage
180/215 V DC -15 % / +10 %, Actuator for external motor brake

Short-circuit rating

Rated conditional short-circuit current (Iq)
10 kA
Rated conditional short-circuit current (Iq), type 2, 380 V, 400 V, 415 V
0 A
Short-circuit protection (external output circuits)
Type 1 coordination via the power bus' feeder unit, Main circuit

Control circuit

Rated control supply voltage (Us) at AC, 50 Hz - min
0 V
Rated control supply voltage (Us) at AC, 50 Hz - max
0 V
Rated control supply voltage (Us) at AC, 60 Hz - min
0 V
Rated control supply voltage (Us) at AC, 60 Hz - max
0 V
Rated control supply voltage (Us) at DC - min
0 V
Rated control supply voltage (Us) at DC - max
0 V
Rated control voltage (Uc)
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
180/207 V DC (external brake 50/60 Hz)

Communication

Connection
Connections pluggable in power section
Interfaces
Number of slave addresses: 31 (AS-Interface®)
Max. total power consumption from AS-Interface® power supply unit (30 V): 190 mA
Specification: S-7.4 (AS-Interface®)

Contacts

Number of auxiliary contacts (normally closed contacts)
0
Number of auxiliary contacts (normally open contacts)
0

Cable

Cable length
10 m, Radio interference level, maximum motor cable length

Design verification

10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 199068 Interruptores de baja tensión (EC001037)
Característica Valor
Tipo de arrancador de motor (EF009598) Motor de arranque directo
Con liberación de cortocircuito (EF006691)
Voltaje nominal de suministro piloto piloto para CA 50 Hz (EF003978) 0 V
Voltaje nominal de suministro piloto piloto para CA 60 Hz (EF003979) 0 V
Voltaje nominal de suministro piloto de piloto para CC (EF003980) 0 V
Tipo de tensión de accionamiento (EF008242) CC
Potencia asignada de empleo con AC-3, 230 V, trifásica (EF009599) 0 kW
Potencia de funcionamiento nominal en CA-3, 400 V (EF001364) 3 kW
Potencia asignada, 460 V, 60 Hz, trifásica (EF009600) 2.238 kW
Potencia asignada, 575 V, 60 Hz, trifásica (EF009601) 0 kW
Corriente nominal de funcionamiento Ie (EF001443) 6.6 A
Intensidad asignada de empleo con AC-3, 400 V (EF009602) 6.6 A
Ajuste actual de liberación de sobrecarga (EF002336) 0.3 A
Corriente condicional asignada de cortocircuito, tipo 1, 480 Y/277 V (EF009607) 10000 A
Corriente condicional asignada de cortocircuito, tipo 1, 600 Y/347 V (EF009608) 0 A
Corriente condicional asignada de cortocircuito, tipo 2, 230V (EF009606) 0 A
Corriente condicional asignada de cortocircuito, tipo 2, 400V (EF009605) 0 A
Consumo de energía (EF000346) 8 W
Número de contactos auxiliares normalmente abiertos (EF001376) 0
Número de contactos auxiliares normalmente cerrados (EF001377) 0
Temperatura ambiente, límite superior sin restricciones (EF009603) 55 °C
Protección contra sobrecargas, termocompensada (EF009604)
Clase de disparo (EF006668) CLASE 10 A
Tipo de conexión del circuito de corriente principal (EF006819) Conexión enchufable
Tipo de conexión eléctrica para circuitos auxiliares y de control (EF006979) Conexión enchufable
Montaje en carril posible (EF003972) No
Con transformador (EF000278) No
Número de puestos de mando (EF001372) 1
Apto para parada de emergencia (EF001433) No
Tipo de clasificación según IEC 60947-4-3 (EF012390) Clase 1
Número de luces indicadoras (EF001965) 0
Reinicio externo posible (EF003426)
Con fusible (EF006693) No
Grado de protección (IP) (EF005474) IP65
Grado de protección (NEMA) (EF011959) 12
Soporta el protocolo TCP/IP (EF003050) No
Soporta el protocolo PROFIBUS (EF003052) No
Soporta el protocolo CAN (EF003053) No
Soporta el protocolo INTERBUS (EF003054) No
Soporta el protocolo ASI (EF003051)
Soporta el protocolo Modbus (EF003057) No
Soporta el protocolo de autopista de datos (EF003058) No
Soporta el protocolo DeviceNet (EF003059) No
Soporta el protocolo SUCONET (EF003060) No
Soporta el protocolo LON (EF003017) No
Soporta el protocolo PROFINET IO (EF007525) No
Soporta el protocolo PROFINET CBA (EF007524) No
Soporta el protocolo SERCOS (EF006657) No
Soporta el protocolo Foundation Fieldbus (EF007522) No
Soporta el protocolo Ethernet/IP (EF007521) No
Soporta el protocolo AS-Interface Safety at Work (EF007519) No
Soporta el protocolo DeviceNet Safety (EF007520) No
Soporta el protocolo de seguridad INTERBUS (EF006662) No
Soporta el protocolo PROFIsafe (EF007526) No
Soporta el protocolo SafetyBUS p (EF007527) No
Soporta el protocolo para otros sistemas bus (EF003062) No
Anchura (EF000008) 220 mm
Altura (EF000040) 270 mm
Profundidad (EF000049) 120 mm

Datasheet - PDF

Opiniones: (0)

Ningún comentario por el momento.

Añadir comentario
ocultar
Valoración:
Nombre:
Email:
Título:
Opinión:
  Captcha
  Añadir comentario

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.