5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...

Images are for illustrative purposes only. Please refer to data sheet for details.
Reference: VAL-US 60/O-FM
Code: 2906280
Manufacturer: PHOENIX CONTACT
Description:
Categories:
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT
* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.
Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.
LAST VIEWED
| Product type | Surge protection for NEMA power supply units |
| Product family | VALVETRAB MS |
| IEC test classification | II |
| T2 | |
| EN type | T2 |
| Type | DIN rail module, two-section, divisible |
| Number of positions | 1 |
| Surge protection fault message | Optical, remote indicator contact |
| Insulation characteristics | |
| Pollution degree | 2 |
| Nominal frequency fN | 50 Hz (60 Hz) |
| Indicator/remote signaling | |
| Connection name | Remote fault indicator contact |
| Switching function | Changeover contact |
| Operating voltage | 5 V AC ... 250 V AC |
| 125 V AC (UL) | |
| 125 V DC (200 mA DC) | |
| Operating current | 5 mA AC ... 1.5 A |
| 1 A (UL) | |
| 1 A (30 V DC) | |
| Connection method | Biconnect terminal blocks |
| Screw thread | M5 |
| Tightening torque | 3 Nm ... 4.5 Nm (UL) |
| 27 lbf-in. ... 40 lbf-in. (UL) | |
| Stripping length | 16 mm |
| Conductor cross section flexible min. | 1.5 mm² |
| Conductor cross section flexible max. | 25 mm² |
| Conductor cross section, rigid min. | 1.5 mm² |
| Conductor cross section, rigid max. | 35 mm² |
| Conductor cross section AWG | 15 ... 2 (IEC) |
| 14 ... 2 (UL) | |
| Connection method | Screw connection |
| Screw thread | M5 |
| Tightening torque | 4.5 Nm |
| 30 lbf-in. (UL) | |
| Stripping length | 16 mm |
| Conductor cross section flexible min. | 1.5 mm² |
| Conductor cross section flexible max. | 25 mm² |
| Conductor cross section, rigid min. | 1.5 mm² |
| Conductor cross section, rigid max. | 35 mm² |
| Conductor cross section AWG | 15 ... 2 |
| 14 ... 2 (UL) | |
| Remote fault indicator contact | |
| Connection method | Screw connection |
| Screw thread | M2 |
| Tightening torque | 0.25 Nm |
| Stripping length | 7 mm |
| Conductor cross section flexible min. | 0.14 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section, rigid min. | 0.14 mm² |
| Conductor cross section, rigid max. | 1.5 mm² |
| Conductor cross section AWG | 28 ... 16 |
| Dimensional drawing | ![]() |
| Width | 17.6 mm |
| Height | 77.1 mm |
| Depth | 89.2 mm |
| Color | black (RAL 9005) |
| Flammability rating according to UL 94 | V0 |
| Housing material | PBT |
| Mode of protection | L-PEN |
| (L+) - (L-) | |
| (L-) - PE | |
| (L+) - PE | |
| Direction of action | L-N / L-PEN |
| Nominal voltage UN | 60 V DC |
| -48 V DC (RRH) | |
| Nominal frequency fN | 50 Hz (60 Hz) |
| Maximum continuous voltage UC | 75 V AC |
| 100 V DC | |
| Maximum continuous operating voltage UC(L-N) | 75 V AC |
| 100 V DC | |
| Maximum continuous operating voltage UC(L-PEN) | 75 V AC |
| 100 V DC | |
| Rated load current IL | 80 A |
| Residual current IPE | ≤ 0.45 mA |
| Standby power consumption PC | ≤ 35 mVA |
| Nominal discharge current In(8/20) µs | 15 kA |
| Nominal discharge current In(8/20) µs (L-N) | 15 kA |
| Nominal discharge current In(8/20) µs (L-PEN) | 15 kA |
| Maximum discharge current Imax(8/20) µs | 40 kA |
| Maximum discharge current Imax(8/20) µs (L-N) | 40 kA |
| Maximum discharge current Imax(8/20) µs (L-PEN) | 40 kA |
| Short-circuit current rating ISCCR | 25 kA |
| Voltage protection level Up | ≤ 0.55 kV |
| Voltage protection level Up(L-N) | ≤ 0.55 kV |
| Voltage protection level Up(L-PEN) | ≤ 0.55 kV |
| Residual voltage Ures | ≤ 0.55 kV (at In) |
| ≤ 0.425 kV (at 10 kA) | |
| ≤ 0.325 kV (at 5 kA) | |
| ≤ 0.275 kV (at 3 kA) | |
| TOV behavior at UT | 100 V AC (5 s / withstand mode) |
| TOV behavior at UT(L-N) | 100 V AC (5 s / withstand mode) |
| TOV behavior at UT(L-PEN) | 100 V AC (5 s / withstand mode) |
| Response time tA | ≤ 25 ns |
| Response time tA(L-N) | ≤ 25 ns |
| Response time tA(L-PEN) | ≤ 25 ns |
| Max. backup fuse with V-type through wiring | 80 A AC (gG) |
| Max. backup fuse with branch wiring | 125 A AC (gG) |
| Ambient conditions | |
| Degree of protection | IP20 (only when all terminal points are used) |
| Ambient temperature (operation) | -40 °C ... 80 °C |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | max. 2000 m |
| Permissible humidity (operation) | 5 % ... 95 % |
| Shock (operation) | 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
| Vibration (operation) | 5g (10 ... 500 Hz / 2.5 h / X, Y, Z) |
| UL specifications | |
| Maximum continuous operating voltage MCOV | 75 V AC |
| Maximum continuous operating voltage MCOV (L-N) | 75 V AC |
| Maximum continuous operating voltage MCOV (L-G) | 75 V AC |
| Maximum continuous operating voltage MCOV (L+) - (L-) | 100 V DC |
| Maximum continuous operating voltage MCOV (L+/L-) - G | 100 V DC |
| Voltage protection rating VPR | 500 V |
| Voltage protection rating VPR (L-N) | 0.5 kV |
| Voltage protection rating VPR (L+) - (L-) | 0.33 kV |
| Voltage protection rating VPR (L+/L-) -G | 0.33 kV |
| Nominal discharge current In | 10 kA |
| Nominal discharge current In(L-N) | 10 kA |
| Nominal discharge current In(L+) - (L-) | 10 kA |
| Nominal discharge current In(L+/L-) - G | 10 kA |
| Mode of protection | L-L |
| L-G | |
| (L+) - (L-) | |
| (L+) - G | |
| (L-) - G | |
| Nominal voltage | 60 V DC |
| Power distribution system | Single phase |
| Measured limiting voltage MLV | 630 V |
| Measured limiting voltage MLV (L-N) | 630 V |
| SPD Type | 4CA |
| UL indicator/remote signaling | |
| Operating voltage | 125 V AC |
| AC operating current | 1 A AC |
| UL connection data | |
| Tightening torque | 30 lbf-in. |
| Conductor cross section AWG | 14 ... 2 |
| Air clearances and creepage distances | |
| Standards/regulations | EN 61643-11 / UL 840 |
| Standards/specifications | EN 61643-11/A11 |
| Note | 2007 |
| Mounting type | DIN rail: 35 mm |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.
5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...
5/5 merci beaucoup
— sotitradim 11/29/25, 11:12 AM
Product:SL20,MNM,IP42,300lm,1H SL2MNM42H1C EATON...
4/5 a,azing to use it
— B rahul 10/4/25, 8:05 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP
4/5 Amazing to use it
— B rahul 10/4/25, 8:04 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP