PHOENIX CONTACT  VAL-US-120/40/2+1-FM 2910352 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

VAL-US-120/40/2+1-FM 2910352 PHOENIX CONTACT Type 2 surge protection device

Reference: VAL-US-120/40/2+1-FM

Code: 2910352

Manufacturer: PHOENIX CONTACT

Description:

Type 2 surge protection device
3-channel surge protection device with remote indication contact, for 120/240 V AC (split phase configuration), 3 wires plus ground.

Categories:

  • Earthing, lightning and surge protection > Surge protection device for power supply systems
  • PHOENIX CONTACT > Trabtech (TT)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT

  • More Info
  • ETIM
  • Reviews
Guarantee, repair and return.

Unit Price: 201,44 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 2-3 weeks.

  • These delivery times are an estimate any may vary when the item order has been processed.

LAST VIEWED

MORE INFO

Key Commercial Data

Orderkey2910352
Packing unit1 pc
NoteMade to Order (non-returnable)
GTIN4055626444925
Weight per Piece (excluding packing)283.000 g
Custom tariff number85363030
Country of originUS (United States)

Dimensions

Height98.7 mm
Width53.4 mm
Depth65.5 mm
Horizontal pitch3 Div.

Ambient conditions

Degree of protectionIP20 (only when all terminal points are used)
Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %
Shock (operation)25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)5g (10 ... 500 Hz / 2.5 h / X, Y, Z)

General

IEC test classificationII
T2
EN typeT2
IEC power supply systemTN-S
TT
Mode of protectionL-N
L-PE
N-PE
Mounting typeDIN rail: 35 mm
Colorjet black RAL 9005
Housing materialPA 6.6
PBT
Degree of pollution2
Flammability rating according to UL 94V-0
TypeDIN rail module, two-section, divisible
Number of positions3
Surge protection fault messageOptical, remote indicator contact

Protective circuit

Nominal voltage UN120/240 V AC (TN-S)
120/240 V AC (TT)
Nominal frequency fN50 Hz (60 Hz)
Rated load current IL80 A
Residual current IPE5 µA
Nominal discharge current In(8/20) µs20 kA
Follow current interrupt rating Ifi(N-PE)100 A (305 V AC)
Short-circuit current rating ISCCR25 kA
Voltage protection level Up(L-N)≤ 0.9 kV
Voltage protection level Up(L-PE)≤ 1.6 kV
Voltage protection level Up(N-PE)≤ 1.5 kV
Residual voltage Ures(L-N)≤ 0.9 kV (at In)
≤ 0.75 kV (at 10 kA)
≤ 0.6 kV (at 5 kA)
≤ 0.55 kV (at 3 kA)
Residual voltage Ures(L-PE)≤ 1.6 kV (at In)
≤ 1.2 kV (at 10 kA)
≤ 1 kV (at 5 kA)
≤ 0.9 kV (at 3 kA)
Residual voltage Ures(N-PE)≤ 0.4 kV (at In)
≤ 0.25 kV (at 10 kA)
≤ 0.15 kV (at 5 kA)
≤ 0.1 kV (at 3 kA)
TOV behavior at UT(L-N)208 V AC (5 s / withstand mode)
240 V AC (120 min / safe failure mode)
TOV behavior at UT(N-PE)1200 V AC (200 ms / withstand mode)
Response time tA(L-N)≤ 25 ns
Response time tA(L-PE)≤ 100 ns
Response time tA(N-PE)≤ 100 ns
Max. backup fuse with V-type through wiring80 A (gG)
Max. backup fuse with branch wiring125 A (gG)

Indicator/remote signaling

Switching functionPDT contact
Operating voltage5 V AC ... 250 V AC
30 V DC
Operating current5 mA AC ... 1.5 A AC
1 A DC
Connection methodScrew connection
Screw threadM2
Tightening torque0.25 Nm
Stripping length7 mm
Conductor cross section flexible0.14 mm² ... 1.5 mm²
Conductor cross section solid0.14 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16

Connection data

Connection methodScrew connection
Screw threadM5
Tightening torque4.5 Nm (1,5 mm² ... 16 mm²)
4.5 Nm (25 mm² ... 35 mm²)
Stripping length16 mm
Conductor cross section flexible1.5 mm² ... 25 mm²
Conductor cross section solid1.5 mm² ... 35 mm²
Conductor cross section AWG15 ... 2

UL specifications

SPD Type1
Maximum continuous operating voltage MCOV (L-L)350 V AC
Maximum continuous operating voltage MCOV (L-N)175 V AC
Maximum continuous operating voltage MCOV (L-G)175 V AC
Maximum continuous operating voltage MCOV (N-G)305 V AC
Nom. voltage120/240 V AC (Split phase)
Mode of protectionL-L
L-N
L-G
N-G
Power distribution systemSplit phase
Nominal frequency50/60 Hz
Voltage protection rating VPR (L-L)1200 V
Voltage protection rating VPR (L-N)700 V
Voltage protection rating VPR (L-G)1800 V
Voltage protection rating VPR (N-G)1200 V
Nominal discharge current In20 kA
Maximum Surge Current per Phase40 kA
Short-circuit current rating (SCCR)200 kA

UL indicator/remote signaling

Operating voltage125 V AC
Operating current1 A AC
Tightening torque2 lbf-in. ... 4 lbf-in.
Conductor cross section AWG30 ... 14

UL connection data

Conductor cross section AWG10 ... 2
Tightening torque30 lbf-in.

Standards and Regulations

Standards/regulationsIEC 61643-11 2011
EN 61643-11 2012

Classifications

ETIM for 2910352 Earthing, lightning and surge protection (EC000941)

Feature nameSystem configuration DC (EF009926)
Feature valueNo
Feature nameSystem configuration IT (EF009927)
Feature valueNo
Feature nameSystem configuration TN (EF009928)
Feature valueNo
Feature nameSystem configuration TN-C (EF009929)
Feature valueNo
Feature nameSystem configuration TN-C-S (EF009933)
Feature valueNo
Feature nameSystem configuration TN-S (EF009930)
Feature valueYes
Feature nameSystem configuration TT (EF009931)
Feature valueNo
Feature nameSystem configuration other (EF009932)
Feature valueNo
Feature nameNominal discharge surge current (8/20) (EF004214)
Feature value20 kA
Feature nameVoltage protection level (EF003525)
Feature value1.6 kV
Feature nameVoltage protection level L-N (EF004236)
Feature value0.9 kV
Feature nameVoltage protection level N-PE (EF008796)
Feature value1.5 kV
Feature nameMax. overcurrent protection device, parallel connection (fuse) (EF015962)
Feature value125 A
Feature nameMax. overcurrent protection device, series connection (fuse) (EF015963)
Feature value80 A
Feature nameShort-circuit breaking capacity (Isccr) (EF012627)
Feature value25 kA
Feature nameIntegrated backup fuse (EF008797)
Feature valueYes
Feature nameLeakage-current free (EF016002)
Feature valueNo
Feature nameMounting method (EF000003)
Feature valueDIN rail (top hat rail) 35 mm
Feature nameConstruction size (EF002566)
Feature valueOther
Feature nameMax. conductor cross section solid (solid, stranded) (EF008827)
Feature value1.5 mm²
Feature nameMax. conductor cross section flexible (fine-strand) (EF008828)
Feature value25 mm²
Feature nameWith remote signalling contact (EF000422)
Feature valueYes
Feature nameSignalling at the device (EF004241)
Feature valueOptic
Feature nameCategory type 2 (EF004230)
Feature valueYes
Feature nameDegree of protection (IP) (EF005474)
Feature valueIP20

DATASHEET - PDF

Title
Size
Type

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.