FLT-PLUS 2800116 PHOENIX CONTACT Combination type 1/2 protective device

Reference: FLT-PLUS

Code: 2800116

Manufacturer: PHOENIX CONTACT

Description:

Combination type 1/2 protective device
Type 1 / Class I (lightning current discharger) with Arc-Cpping arc discharger, extinguishing plates for high corr extinguishing capacity. repetitive network, 1 channel. Housing width: 35 mm (2 pcs)

Categories:

  • PHOENIX CONTACT > Trabtech (TT)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

MORE INFO

Key Commercial Data

Orderkey2800116
Packing unit1 pc
Catalog pagePage 23 (TT-2011)
GTIN4046356480017
Weight per Piece (excluding packing)519.100 g
Custom tariff number85363030
Country of originDE (Germany)

Dimensions

Height150 mm
Width35.5 mm
Depth65.5 mm
Horizontal pitch2 Div.

Ambient conditions

Degree of protectionIP20 (only when all terminal points are used)
Ambient temperature (operation)-40 °C ... 85 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %

General

IEC test classificationI
T1
EN typeT1
IEC power supply systemTT
TN-C
TN-S
Mode of protectionL-PEN
Mounting typeDIN rail: 35 mm
Colorblack
Housing materialPA 6.6
Degree of pollution2
Flammability rating according to UL 94V-0
TypeDIN rail module, one-piece
Number of positions1
Surge protection fault messagenone

Protective circuit

Nominal voltage UN230/400 V AC (TN)
230/400 V AC (TT)
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous operating voltage UC(L-PEN)440 V AC
Rated load current IL80 A
Residual current IPE≤ 0.1 mA
Standby power consumption PC≤ 44 mVA
Nominal discharge current In(8/20) µs (L-PEN)50 kA
Impulse discharge current (10/350) µs, charge25 As
Impulse discharge current (10/350) µs, specific energy625 kJ/Ω
Impulse discharge current (10/350) µs, peak value limp50 kA
Follow current interrupt rating Ifi(L-PEN)25 kA
Short-circuit current rating ISCCR25 kA
Voltage protection level Up(L-PEN)≤ 5 kV
Front of wave sparkover voltage at 6 kV (1.2/50) µs≤ 5 kV
TOV behavior at UT(L-PEN)440 V AC (5 s / withstand mode)
440 V AC (120 min / withstand mode)
Response time tA(L-PEN)≤ 100 ns
Max. backup fuse with V-type through wiring80 A AC (gG)
Max. backup fuse with branch wiring500 A AC (gG)

Connection data

Connection methodScrew connection
Screw threadM6
Tightening torque8 Nm
Stripping length19 mm
Conductor cross section flexible min.16 mm²
Conductor cross section flexible max.35 mm²
Conductor cross section solid min.10 mm²
Conductor cross section solid max.50 mm²
Conductor cross section AWG6 ... 1

Standards and Regulations

Standards/regulationsIEC 61643-11 2011
EN 61643-11 2012

Classifications

ETIM for 2800116 Earthing, lightning and surge protection (EC000381)

Feature nameSystem configuration DC (EF009926)
Feature valueNo
Feature nameSystem configuration IT (EF009927)
Feature valueNo
Feature nameSystem configuration TN (EF009928)
Feature valueNo
Feature nameSystem configuration TN-C (EF009929)
Feature valueNo
Feature nameSystem configuration TN-C-S (EF009933)
Feature valueNo
Feature nameSystem configuration TN-S (EF009930)
Feature valueNo
Feature nameSystem configuration TT (EF009931)
Feature valueYes
Feature nameSystem configuration other (EF009932)
Feature valueNo
Feature nameLightning impulse current (10/350 µs) (EF000421)
Feature value50 kA
Feature nameMax. continuous voltage AC (EF004198)
Feature value440 V
Feature nameFollow current extinguishing capability (EF004193)
Feature value25 kA
Feature nameMounting method (EF000003)
Feature valueDIN rail (top hat rail) 35 mm
Feature nameConstruction size (EF002566)
Feature valueOther
Feature nameMax. conductor cross section solid (solid, stranded) (EF008827)
Feature value50 mm²
Feature nameMax. conductor cross section flexible (fine-strand) (EF008828)
Feature value35 mm²
Feature nameWith remote signalling contact (EF000422)
Feature valueNo
Feature nameExhausting (EF004181)
Feature valueNo
Feature nameSignalling at the device (EF004241)
Feature valueNone
Feature nameCategory type 1 (EF004229)
Feature valueYes
Feature nameIntegrated backup fuse (EF008797)
Feature valueYes
Feature nameSuitable for outdoor use (EF003532)
Feature valueNo
Feature nameDegree of protection (IP) (EF005474)
Feature valueIP20

DATASHEET - PDF

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.