PHOENIX CONTACT  PT 2-F-ST 2859000 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

PT 2-F-ST 2859000 PHOENIX CONTACT Surge protection plug

Reference: PT 2-F-ST

Code: 2859000

Manufacturer: PHOENIX CONTACT

Description:

Surge protection plug
Plug-in surge protection for the base element, surge protection for two signal cables grounded on one side.

Categories:

  • PHOENIX CONTACT > Trabtech (TT)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

LAST VIEWED

MORE INFO

Key Commercial Data

Orderkey2859000
Packing unit10 pc
NoteMade to Order (non-returnable)
Catalog pagePage 115 (C-4-2017)
GTIN4017918902452
Weight per Piece (excluding packing)16.120 g
Custom tariff number85363010
Country of originDE (Germany)

Dimensions

Height45 mm
Width17.7 mm
Depth52 mm
Horizontal pitch1 Div.
Complete module height90 mm
Complete module width17.7 mm
Complete module depth65.5 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 85 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Degree of protectionIP20

General

Housing materialPA 6.6
Flammability rating according to UL 94V-0
Colorjet black RAL 9005
Mounting typeon base element
TypeMale
Direction of actionLine-Earth Ground
Arrester can be tested with CHECKMASTER from software version:From SW rev. 1.10

Protective circuit

IEC test classificationC1
C2
C3
D1
Nominal voltage UN48 V AC
Maximum continuous voltage UC60 V DC
48 V AC
Rated current2 A AC (80 °C)
150 mA DC (80 °C)
Operating effective current ICat UC≤ 2 µA
Residual current IPE≤ 4 µA
Nominal discharge current In(8/20) µs (line-earth)20 kA
Pulse discharge current Iimp(10/350) µs (line-earth)5 kA
Total discharge current Itotal(8/20) µs20 kA
Output voltage limitation at 1 kV/µs (line-earth) spike≤ 600 V
Output voltage limitation at 1 kV/µs (line-earth) static≤ 25 V
Voltage protection level Up(line-earth)≤ 600 V (C2 - 10 kV / 5 kA)
Voltage protection level Upstatic (line-earth)≤ 25 V (C2 - 10 kV / 5 kA)
Response time tA(line-earth)≤ 100 ns
Input attenuation aE, asym.typ. 0.1 dB (≤ 1 MHz / 50 Ω)
Cut-off frequency fg (3 dB), asym. (GND) in 50 Ohm systemtyp. 100 MHz
Capacity (line-earth)typ. 2 pF
Resistance in series0 Ω
Surge protection fault messagenone
Max. required back-up fuse2 A AC (T)
150 mA DC (T)
Impulse durability (line-earth)C2 - 10 kV/5 kA
C1 - 1 kV/500 A
C3 - 100 A
D1 - 2.5 kA

Connection data

Connection methodScrew connection (in connection with the base element)
Screw threadM3
Tightening torque0.5 Nm
Stripping length8 mm
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section solid0.2 mm² ... 4 mm²
Conductor cross section AWG24 ... 12

Standards and Regulations

Standards/specificationsIEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
EN 61643-21 2001 + A1:2009 + A2:2013

Classifications

ETIM for 2859000 Earthing, lightning and surge protection (EC000943)

Feature nameNominal voltage DC (EF008799)
Feature value48 V

DATASHEET - PDF

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.