PHOENIX CONTACT  SFP 1-20/230AC 2859987 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

SFP 1-20/230AC 2859987 PHOENIX CONTACT EMC filter surge protection device

Reference: SFP 1-20/230AC

Code: 2859987

Manufacturer: PHOENIX CONTACT

Description:

EMC filter surge protection device
Device protection, according to type 3/class III, with mains parasitic filter against high-frequency edging voltages, for single-phase power supply networks with separate N and PE (3-conductor system: L1, N, PE), with remote indication contact.

Categories:

  • Earthing, lightning and surge protection > Surge protection device for terminal equipment
  • PHOENIX CONTACT > Trabtech (TT)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Go to successor article:SFP2-1S-1-20A-230AC-UT1292605

Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

LAST VIEWED

MORE INFO

Key Commercial Data

Orderkey2859987
Packing unit1 pc
Catalog pagePage 184 (C-4-2017)
GTIN4046356098175
Weight per Piece (excluding packing)616.000 g
Custom tariff number85363010
Country of originDE (Germany)

Dimensions

Height86.6 mm
Width112 mm
Depth79 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C
Ambient temperature (storage/transport)-25 °C ... 70 °C
Permissible humidity (operation)5 % ... 95 %

General

EN typeT3
Number of portsTwo
Mode of protectionL-N
L-PE
N-PE
Mounting typeDIN rail: 35 mm
Colorblack
silver
Housing materialAluminum
Degree of pollution2
Flammability rating according to UL 94V-0
TypeDIN rail module, one-piece
Number of positions2
Surge protection fault messageOptical, remote indicator contact
For country-specific use inD, A, I, NL, S, E, FIN, P

Protective circuit

Nominal voltage UN240 V AC (TN)
240 V AC (TT - only in use with RCD)
240 V AC (IT - only in use with RCD)
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous voltage UC264 V AC
Rated load current IL20 A (40 °C)
Residual current IPE≤ 0.6 mA
Nominal discharge current In(8/20) µs5 kA
Standby power consumption PC≤ 25 VA (at UREF)
≤ 27.5 VA (at UC)
Reference test voltage UREF264 V AC
Combination wave UOC10 kV (5 kA)
Voltage protection level Up≤ 1 kV
TOV behavior at UT(L-N)350 V AC (5 s / withstand mode)
457 V AC (120 min / safe failure mode)
TOV behavior at UT(L-PE)457 V AC (5 s / withstand mode)
350 V AC (120 min / withstand mode)
1464 V AC (200 ms / safe failure mode)
TOV behavior at UT(N-PE)1200 V AC (200 ms / safe failure mode)
Response time tA≤ 25 ns
Capacity (L-N)1 µF ±10 %
10 nF ±10 % (X2-275 V)
Capacity (L-PE)2.2 nF ±20 % (Y2-250 V)
Capacity (L-PEN)2.2 nF ±20 % (Y2-250 V)
Max. required back-up fuse20 A (MCB B/general purpose)
16 A (IT - MCB B/general purpose)
Input attenuation aE, sym.20 dB (≥ 100 kHz / 50 Ω)
Input attenuation aE, asym.30 dB (≥ 1 MHz / 50 Ω)
Short-circuit current rating ISCCR5 kA AC (TN/TT)
1 kA AC (IT)

Indicator/remote signaling

Switching functionPDT contact
Operating voltage12 V AC ... 250 V AC
250 V DC (250 mA DC)
Operating current100 mA AC ... 1 A AC
1 A DC (48 V DC)
Connection methodPluggable screw connection
Conductor cross section flexible0.14 mm² ... 1.5 mm²
Conductor cross section solid0.14 mm² ... 1.5 mm²
Conductor cross section AWG26 ... 16
Screw threadM2
Tightening torque0.25 Nm
Stripping length7 mm

Connection data

Connection methodScrew terminal blocks
Conductor cross section flexible2.5 mm² ... 4 mm²
Conductor cross section solid2.5 mm² ... 6 mm²
Conductor cross section AWG14 ... 10
Screw threadM3
Tightening torque0.5 Nm ... 0.6 Nm
4.5 lbf-in. ... 5.5 lbf-in.
Stripping length8 mm

Protective circuit, filter

Discharge resistance820 kΩ

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

ETIM for 2859987 Earthing, lightning and surge protection (EC000942)

Feature nameMax. continuous voltage AC (EF004198)
Feature value264 V
Feature nameVoltage protection level L-N (EF004236)
Feature value1 kV
Feature nameMounting method (EF000003)
Feature valueDIN rail (top hat rail) 35 mm
Feature nameMax. conductor cross section solid (solid, stranded) (EF008827)
Feature value6 mm²
Feature nameMax. conductor cross section flexible (fine-strand) (EF008828)
Feature value4 mm²
Feature nameWith remote signalling contact (EF000422)
Feature valueYes
Feature nameSignalling at the device (EF004241)
Feature valueOptic
Feature nameCategory type 3 (EF004231)
Feature valueYes
Feature nameDegree of protection (IP) (EF005474)
Feature valueIP20

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.