5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...

Images are for illustrative purposes only. Please refer to data sheet for details.
Reference: PLT-SEC-T3-60-FM-UT
Code: 2907917
Manufacturer: PHOENIX CONTACT
Description:
Categories:
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT
LAST VIEWED
| Orderkey | 2907917 |
|---|---|
| Packing unit | 5 pc |
| GTIN | 4055626257426 |
| Weight per Piece (excluding packing) | 81.160 g |
| Custom tariff number | 85363030 |
| Country of origin | DE (Germany) |
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -40 °C ... 80 °C |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m (operating voltage remote contact ≤ 250 V) |
| ≤ 6000 m (operating voltage remote contact ≤ 150 V) | |
| Permissible humidity (operation) | 5 % ... 95 % |
| Shock (operation) | 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
| Vibration (operation) | 5g (5 ... 500 Hz / 2.5 h / X, Y, Z) |
| EN type | T3 |
|---|---|
| IEC power supply system | TN-S |
| Number of ports | One |
| Mode of protection | L-N |
| L-PE | |
| N-PE | |
| Mounting type | DIN rail: 35 mm |
| Color | light grey RAL 7035 |
| traffic grey A RAL 7042 | |
| Housing material | PA 6.6-FR 20% GF |
| PA 6.6-FR | |
| Degree of pollution | 2 |
| Flammability rating according to UL 94 | V-0 |
| Type | DIN rail module, two-section, divisible |
| Number of positions | 2 |
| Surge protection fault message | Optical, remote indicator contact |
| Nominal voltage UN | 60 V AC (TN-S) |
|---|---|
| Nominal frequency fN | 50 Hz (60 Hz) |
| Maximum continuous voltage UC | 80 V AC |
| Rated load current IL | 26 A (at 30 °C) |
| Residual current IPE | ≤ 5 µA |
| Nominal discharge current In(8/20) µs | 2 kA |
| Standby power consumption PC | ≤ 5.3 mVA (at UREF) |
| ≤ 8.4 mVA (at UC) | |
| Reference test voltage UREF | 66 V AC |
| Combination wave UOC | 4 kV |
| Voltage protection level Up(L-N) | ≤ 0.48 kV |
| Voltage protection level Up(L-PE) | ≤ 0.8 kV |
| Voltage protection level Up(N-PE) | ≤ 0.8 kV |
| TOV behavior at UT(L-N) | 120 V AC (120 min / withstand mode) |
| TOV behavior at UT(L-PE) | 120 V AC (120 min / withstand mode) |
| Response time tA(L-N) | ≤ 25 ns |
| Response time tA(L-PE) | ≤ 100 ns |
| Response time tA(N-PE) | ≤ 100 ns |
| Short-circuit current rating ISCCR | 10 kA AC |
| Max. backup fuse with branch wiring | 32 A (gG / B / C) |
| Maximum backup fuse for through wiring | 25 A (gG / B / C) |
| Short-circuit current rating ISCCR | 0.25 kA DC (without additional backup fuse) |
|---|---|
| 5 kA DC (for 20 A gG / B backup fuse) | |
| Maximum discharge current Imax(8/20) µs | 4 kA |
| Maximum continuous voltage UC | 80 V DC |
| Mode of protection | (DC+) - (DC-) |
| (DC+/DC-) - PE |
| Switching function | PDT contact |
|---|---|
| Operating voltage | 250 V AC |
| 125 V DC (200 mA DC) | |
| Operating current | 0.5 A AC |
| 0.5 A DC (75 V DC) | |
| Connection method | Screw connection |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section solid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 30 ... 12 |
| Screw thread | M3 |
| Tightening torque | 0.5 Nm |
| Stripping length | 10 mm |
| Connection method | Screw connection |
|---|---|
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section solid | 0.2 mm² ... 4 mm² |
| Conductor cross section AWG | 24 ... 12 |
| Screw thread | M3 |
| Tightening torque | 0.5 Nm |
| Stripping length | 10 mm |
| SPD Type | 4CA |
|---|---|
| Maximum continuous operating voltage MCOV | 100 V AC |
| 80 V DC | |
| Nominal voltage | 80 V DC |
| Rated load current IL | 20 A |
| Mode of protection | L-N |
| L-G | |
| N-G | |
| (DC+) - (DC-) | |
| (DC+) - G | |
| (DC-) - G | |
| Power distribution system | Single phase |
| DC | |
| Nominal frequency | 50/60 Hz |
| Measured limiting voltage MLV (L-N) | 490 V |
| Measured limiting voltage MLV (L-G) | 680 V |
| Measured limiting voltage MLV (N-G) | 680 V |
| Nominal discharge current In | 3 kA |
| Operating voltage | 250 V AC (0.5 A) |
|---|---|
| 12 V DC (4 A) | |
| 24 V DC (2 A) | |
| 48 V DC (1 A) | |
| Tightening torque | 5 lbf-in. ... 7 lbf-in. |
| Conductor cross section AWG | 30 ... 12 |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.
5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...
5/5 merci beaucoup
— sotitradim 11/29/25, 11:12 AM
Product:SL20,MNM,IP42,300lm,1H SL2MNM42H1C EATON...
4/5 a,azing to use it
— B rahul 10/4/25, 8:05 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP
4/5 Amazing to use it
— B rahul 10/4/25, 8:04 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP